ENVIRONMENTAL EXPRESS Turbidity Meter, 0 to 1000 NTU

The ENVIRONMENTAL EXPRESS Turbidity Meter (MPN 3563522) measures turbidity from 0 to 1000 NTU with an accuracy of ≤ +/-2% of reading plus stray light. It offers selectable resolution of 1 NTU, 0.1 NTU, or 0.01 NTU…

SKU 3G-OTH-371203

Brand
ENVIRONMENTAL EXPRESS
Item
Turbidity Meter, 0 to 1000 NTU
Category
Turbidity Meters
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

ENVIRONMENTAL EXPRESS
Manufacturer Part Number
3563522
Range
0 to 1000 NTU
Includes
Rechargeable Lithium Battery
Product Type
Turbidity Meter
Turbidity Accuracy
≤ +/-2% of Reading + Stray Light
NTU 0.1 NTU 0.01 NTU Turbidity Resolution
1

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

ENVIRONMENTAL EXPRESS Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The ENVIRONMENTAL EXPRESS Turbidity Meter (MPN 3563522) measures turbidity from 0 to 1000 NTU with an accuracy of ≤ +/-2% of reading plus stray light. It offers selectable resolution of 1 NTU, 0.1 NTU, or 0.01 NTU and includes a rechargeable lithium battery.

Frequently Asked Questions

What is the ENVIRONMENTAL EXPRESS Turbidity Meter used for?

This turbidity meter measures water clarity from 0 to 1000 NTU, commonly used in wastewater treatment, drinking water monitoring, and environmental testing. It helps detect suspended particles in liquids, ensuring compliance with regulatory standards.

What are the specifications of the ENVIRONMENTAL EXPRESS Turbidity Meter 3563522?

The ENVIRONMENTAL EXPRESS Turbidity Meter (MPN 3563522) has a range of 0 to 1000 NTU with accuracy ≤ +/-2% of reading plus stray light. It offers selectable resolution of 1 NTU, 0.1 NTU, or 0.01 NTU and includes a rechargeable lithium battery.

Where to buy the ENVIRONMENTAL EXPRESS Turbidity Meter worldwide?

You can source the ENVIRONMENTAL EXPRESS Turbidity Meter (MPN 3563522) through 3G Electric, a global industrial equipment distributor. We handle full logistics, customs clearance, and delivery to worldwide destinations, ensuring a seamless procurement process.

How to maintain the ENVIRONMENTAL EXPRESS Turbidity Meter?

To maintain accuracy, regularly clean the sample cell with a lint-free cloth and store the meter in a dry, cool place. Recharge the lithium battery as needed and calibrate per the manufacturer's instructions. Avoid exposing the unit to extreme temperatures or direct sunlight.

Used in

Common applications for ENVIRONMENTAL EXPRESS
Wastewater treatment — Environmental Express benchtop multiparameter meter kit (MPN 3541978) for BOD and dissolved oxygen monitoring
Drinking water quality testing — Environmental Express chlorine reagent kit (MPN 9956195) for total chlorine analysis
Industrial process control — Environmental Express benchtop multiparameter meter (MPN 3541962) for conductivity and temperature measurement
Environmental field sampling — Environmental Express handheld multiparameter meter kit (MPN 300 Series) for ORP and pH measurement
Laboratory research — Environmental Express pH electrode (MPN 5900165) for precise pH measurement in liquid samples
Water treatment plant calibration — Environmental Express benchtop multiparameter meter kit (MPN 3541950) with calibration solutions for conductivity and pH

ENVIRONMENTAL EXPRESS Products

3G Electric supplies ENVIRONMENTAL EXPRESS turbidity meters. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
The EXTECH TB400 is a portable turbidity meter with a measurement range of 0 to 1000 NTU, accuracy of ±0.5 NTU, and resolution of 0.01 NTU. It complies with ISO 7027 and includes batteries. Suitable for field or laboratory water quality testing
EXTECH
The EXTECH TB400 is a portable turbidity meter with a measurement range of 0 to 1000 NTU, accuracy of ±0.5 NTU, and resolution of 0.01 NTU. It complies with ISO 7027 and includes batteries. Suitable for field or laboratory water quality testing
Turbidity meter for measuring water clarity in the range of 0 to 1000 NTU. Provides accuracy of +/-2% of reading plus stray light. Includes power module. Suitable for field or laboratory use in water quality testing
HACH
Turbidity meter for measuring water clarity in the range of 0 to 1000 NTU. Provides accuracy of +/-2% of reading plus stray light. Includes power module. Suitable for field or laboratory use in water quality testing
Portable turbidity meter for field or laboratory measurement of water clarity. Measures from 0 to 1000 NTU with accuracy of ≤ +/-2% of reading. Includes PClink Software on USB Flash Drive for data management
OAKTON
Portable turbidity meter for field or laboratory measurement of water clarity. Measures from 0 to 1000 NTU with accuracy of ≤ +/-2% of reading. Includes PClink Software on USB Flash Drive for data management
Turbidity meter for measuring water clarity in the range of 0 to 1000 NTU. Accuracy is ±2% of reading plus stray light. Includes USB connectivity for data transfer. Suitable for water quality monitoring in treatment plants and industrial processes
HACH
Turbidity meter for measuring water clarity in the range of 0 to 1000 NTU. Accuracy is ±2% of reading plus stray light. Includes USB connectivity for data transfer. Suitable for water quality monitoring in treatment plants and industrial processes
Turbidity meter for measuring water clarity in field or laboratory applications. Range 0 to 2000 NTU with accuracy ±0.05 over 0-2.5 NTRU/FNRU. Includes water sample bottle. Suitable for environmental monitoring, wastewater treatment, and drinking water analysis
LAMOTTE
Turbidity meter for measuring water clarity in field or laboratory applications. Range 0 to 2000 NTU with accuracy ±0.05 over 0-2.5 NTRU/FNRU. Includes water sample bottle. Suitable for environmental monitoring, wastewater treatment, and drinking water analysis
Turbidity meter with a measurement range of 0 to 2000 NTU and accuracy of ±3% in the 100-1000 NTRU/FNRU range. Includes FNRU standards for calibration. Used for water clarity testing in industrial and laboratory settings
LAMOTTE
Turbidity meter with a measurement range of 0 to 2000 NTU and accuracy of ±3% in the 100-1000 NTRU/FNRU range. Includes FNRU standards for calibration. Used for water clarity testing in industrial and laboratory settings

More from ENVIRONMENTAL EXPRESS

View all ENVIRONMENTAL EXPRESS parts
This turbidity meter measures water clarity over a range of 0 to 1000 NTU with an accuracy of ≤ +/-2% of reading plus stray light. It offers selectable resolution of 1 NTU, 0.1 NTU, or 0.01 NTU and includes a 5V 1A power adapter. Typical applications include monitoring of suspended particles in water treatment and environmental testing
ENVIRONMENTAL EXPRESS
This turbidity meter measures water clarity over a range of 0 to 1000 NTU with an accuracy of ≤ +/-2% of reading plus stray light. It offers selectable resolution of 1 NTU, 0.1 NTU, or 0.01 NTU and includes a 5V 1A power adapter. Typical applications include monitoring of suspended particles in water treatment and environmental testing