We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

EATON NEMA Enclosed Non-Reversing Starter with Electronic Overload - Enclosed Non-Reversing Starters with Electronic Overloads
EATON NEMAEnclosed Non-Reversing Starters with Electronic Overloads

EATON NEMA Enclosed Non-Reversing Starter with Electronic Overload

The EATON NEMA Magnetic Motor Starter is a non-reversing enclosed starter with electronic overloads, featuring three poles, NEMA Size 2, and a 45 A rating. It operates with a 220/240V AC coil and includes a pilot…

SKU 3G-OTH-131042

Also listed as: ECN0524BAAR63DL30 · ECN0524BAA R63 DL30 · ECN0524BAA-R63-DL30

Brand
EATON NEMA
Item
Enclosed Non-Reversing Starter with Electronic Overload
Category
Enclosed Non-Reversing Starters with Electronic Overloads
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

EATON NEMA
Manufacturer Part Number
ECN0524BAA-R63/DL30
Type
NEMA Size 2, 45 A
Poles
3
AC Coil
240V

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

EATON NEMA Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The EATON NEMA Magnetic Motor Starter is a non-reversing enclosed starter with electronic overloads, featuring three poles, NEMA Size 2, and a 45 A rating. It operates with a 220/240V AC coil and includes a pilot light, with auxiliary contacts configured as 1NO/1NC. This starter is designed for three-phase motor control applications.

Frequently Asked Questions

What is the EATON NEMA Magnetic Motor Starter used for?

This enclosed non-reversing starter with electronic overloads controls three-phase motors in industrial applications such as conveyors, pumps, and compressors. It provides reliable starting and stopping while protecting against overload conditions. The pilot light indicates operational status, and the 1NO/1NC auxiliary contacts support remote monitoring or interlocking.

What are the specifications of the EATON NEMA Magnetic Motor Starter?

The EATON NEMA Magnetic Motor Starter (MPN ECN0524BAA-R63/DL30) is a non-reversing, three-pole, NEMA Size 2 starter rated at 45 A. It uses a 220/240V AC coil, includes a pilot light, and has 1NO/1NC auxiliary contacts. Electronic overload protection is integrated, and it is designed for three-phase motor control.

Where to buy the EATON NEMA Magnetic Motor Starter worldwide?

3G Electric supplies the EATON NEMA Magnetic Motor Starter worldwide. As a global industrial equipment distributor since 1990, we handle full logistics, customs clearance, and delivery to your site. Contact us for availability and lead time. We source and deliver this starter to support your motor control needs anywhere.

How to select the correct EATON NEMA Magnetic Motor Starter for a motor?

Match the starter's NEMA Size and current rating to your motor's full-load amps and voltage. For this Size 2, 45 A starter with a 240V AC coil, ensure your motor's FLA does not exceed 45 A and the coil voltage matches your control circuit. Consult the motor nameplate and EATON's selection guidelines for proper sizing.

Used in

Common applications for EATON NEMA
HVAC systems — Eaton NEMA Size 1 starter (27 A) for controlling condenser fan motors in commercial air handlers.
Pumping stations — Eaton NEMA Size 2 starter (45 A) for starting and stopping irrigation pump motors with electronic overload protection.
Material handling — Eaton NEMA Size 0 starter (18 A) for conveyor belt motors in warehouse distribution centers.
Compressor control — Eaton NEMA Size 3 starter (90 A) for reciprocating air compressors requiring non-reversing motor starting.
Machine tools — Eaton NEMA Size 00 starter (9 A) for small lathe or drill press motors with 24V AC control circuits.
Water treatment — Eaton NEMA Size 2 starter (45 A) for aeration blower motors in municipal wastewater plants.

EATON NEMA Products

3G Electric supplies EATON NEMA enclosed non-reversing starters with electronic overloads. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Enclosed non-reversing starter with electronic overload protection for three-phase motor control. Features NEMA Size 2, 45 A rating, 3 poles, 240V AC coil, 1NO/1NC auxiliary contacts, and pilot light. Suitable for industrial applications such as conveyors, pumps, and compressors
EATON NEMA
Enclosed non-reversing starter with electronic overload protection for three-phase motor control. Features NEMA Size 2, 45 A rating, 3 poles, 240V AC coil, 1NO/1NC auxiliary contacts, and pilot light. Suitable for industrial applications such as conveyors, pumps, and compressors
EATON NEMA Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 2, 45 A, 240V AC Coil (MPN ECN0521BAA-R63/D)
EATON NEMA
EATON NEMA Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 2, 45 A, 240V AC Coil (MPN ECN0521BAA-R63/D)
EATON NEMA Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 2, 45 A, 24V AC Coil (MPN ECN0521TAA-R63/DL30)
EATON NEMA
EATON NEMA Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 2, 45 A, 24V AC Coil (MPN ECN0521TAA-R63/DL30)
EATON NEMA Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 2, 45 A, 208V AC Coil (MPN ECN0522EAA-R63/DL30)
EATON NEMA
EATON NEMA Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 2, 45 A, 208V AC Coil (MPN ECN0522EAA-R63/DL30)
Enclosed non-reversing motor starter with electronic overload protection. Three poles, NEMA Size 2, rated 45 A. Coil voltage 120V AC. Includes pilot light and 1NO/1NC auxiliary contacts. Suitable for starting and protecting three-phase motors in industrial applications requiring non-reversing operation
EATON NEMA
Enclosed non-reversing motor starter with electronic overload protection. Three poles, NEMA Size 2, rated 45 A. Coil voltage 120V AC. Includes pilot light and 1NO/1NC auxiliary contacts. Suitable for starting and protecting three-phase motors in industrial applications requiring non-reversing operation
EATON NEMA Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 2, 45 A, Electronic Protection (MPN ECN0524CAA-R63/DL30)
EATON NEMA
EATON NEMA Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 2, 45 A, Electronic Protection (MPN ECN0524CAA-R63/DL30)

More from EATON NEMA

View all EATON NEMA parts
Enclosed non-reversing starter with electronic overload protection for three-phase motor control. NEMA Size 4, 135 A, 3-pole, 208V AC coil. Includes pilot light and auxiliary contacts (1NO/1NC). Suitable for industrial applications such as pumps, conveyors, and compressors
EATON NEMA
Enclosed non-reversing starter with electronic overload protection for three-phase motor control. NEMA Size 4, 135 A, 3-pole, 208V AC coil. Includes pilot light and auxiliary contacts (1NO/1NC). Suitable for industrial applications such as pumps, conveyors, and compressors
This enclosed non-reversing motor starter features NEMA Size 0, 18 A rating, 3 poles, and a 208V AC coil. It includes electronic overload protection, a pilot light, and auxiliary contacts (1NO/1NC). Suitable for controlling three-phase motors in applications such as conveyors, pumps, and fans
EATON NEMA
This enclosed non-reversing motor starter features NEMA Size 0, 18 A rating, 3 poles, and a 208V AC coil. It includes electronic overload protection, a pilot light, and auxiliary contacts (1NO/1NC). Suitable for controlling three-phase motors in applications such as conveyors, pumps, and fans
This enclosed non-reversing starter with electronic overload protection is rated 27 A, NEMA Size 1, with 3 poles and a 208V AC coil. It includes a pilot light and 1NO/1NC auxiliary contacts. Suitable for starting and stopping three-phase motors in applications such as conveyors, pumps, and fans
EATON NEMA
This enclosed non-reversing starter with electronic overload protection is rated 27 A, NEMA Size 1, with 3 poles and a 208V AC coil. It includes a pilot light and 1NO/1NC auxiliary contacts. Suitable for starting and stopping three-phase motors in applications such as conveyors, pumps, and fans
Enclosed non-reversing starter with electronic overload protection for three-phase AC motors. NEMA Size 0, 18 A, 480V AC coil, 3 poles. Includes pilot light and auxiliary contacts 1NO/1NC. Suitable for conveyors, pumps, and fans requiring forward-only motor control
EATON NEMA
Enclosed non-reversing starter with electronic overload protection for three-phase AC motors. NEMA Size 0, 18 A, 480V AC coil, 3 poles. Includes pilot light and auxiliary contacts 1NO/1NC. Suitable for conveyors, pumps, and fans requiring forward-only motor control
This enclosed non-reversing motor starter features electronic overload protection and is rated for 45 A with NEMA Size 2. It has three poles, a 24V AC coil, 1NO/1NC auxiliary contacts, and a pilot light. Suitable for three-phase motor control in industrial applications such as pumps, fans, and conveyors
EATON NEMA
This enclosed non-reversing motor starter features electronic overload protection and is rated for 45 A with NEMA Size 2. It has three poles, a 24V AC coil, 1NO/1NC auxiliary contacts, and a pilot light. Suitable for three-phase motor control in industrial applications such as pumps, fans, and conveyors
This enclosed non-reversing starter with electronic overloads is designed for starting and stopping three-phase AC motors. It features NEMA Size 0, 18 A rating, 3 poles, and a 120V AC coil. Includes a pilot light and auxiliary contacts (1NO/1NC). Suitable for industrial motor control applications such as conveyors, pumps, and fans
EATON NEMA
This enclosed non-reversing starter with electronic overloads is designed for starting and stopping three-phase AC motors. It features NEMA Size 0, 18 A rating, 3 poles, and a 120V AC coil. Includes a pilot light and auxiliary contacts (1NO/1NC). Suitable for industrial motor control applications such as conveyors, pumps, and fans
Enclosed non-reversing motor starter with electronic overload protection. Rated NEMA Size 0, 18 A, 3 poles, 120V AC coil. Includes pilot light and 1NO/1NC auxiliary contacts. Used for starting and protecting three-phase motors in applications such as conveyors, pumps, and compressors
EATON NEMA
Enclosed non-reversing motor starter with electronic overload protection. Rated NEMA Size 0, 18 A, 3 poles, 120V AC coil. Includes pilot light and 1NO/1NC auxiliary contacts. Used for starting and protecting three-phase motors in applications such as conveyors, pumps, and compressors
Three-pole enclosed non-reversing motor starter with electronic overload, NEMA Size 0, rated 18 A. Coil voltage 480V AC. Includes pilot light and 1NO/1NC auxiliary contacts. Used for starting and protecting three-phase motors in applications such as pumps, fans, and conveyors
EATON NEMA
Three-pole enclosed non-reversing motor starter with electronic overload, NEMA Size 0, rated 18 A. Coil voltage 480V AC. Includes pilot light and 1NO/1NC auxiliary contacts. Used for starting and protecting three-phase motors in applications such as pumps, fans, and conveyors