We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

EATON Thermal Unit: 20 Trip Class, FH23 - Electrical
EATONElectrical

EATON Thermal Unit: 20 Trip Class, FH23

EATON Electrical.

SKU 3G-OTH-39637

Also listed as: FH 23 · FH-23

Brand
EATON
Item
Thermal Unit: 20 Trip Class, FH23
Category
Electrical
UNSPSC
39121029 — Isolation transformer
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

EATON
Manufacturer Part Number
FH23

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

EATON Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

EATON Electrical.

Frequently Asked Questions

What is the EATON FH23 thermal unit used for?

The EATON FH23 thermal unit is used for overload protection in motor starters and contactors. It provides Class 20 trip protection, meaning it will trip within 20 seconds at 600% of rated current, safeguarding motors from overheating in industrial electrical systems.

What are the specifications of the EATON FH23 thermal unit?

The EATON FH23 thermal unit has a manufacturer part number FH23 and is a Class 20 trip class device. It is designed for use with EATON motor starters and contactors to provide thermal overload protection. For exact current ratings, consult the product datasheet.

Where to buy the EATON FH23 thermal unit worldwide?

You can source the EATON FH23 thermal unit through 3G Electric, a global industrial equipment distributor. We handle full logistics, customs clearance, and delivery to worldwide destinations, ensuring compliance with international shipping requirements.

How to install the EATON FH23 thermal unit?

To install the EATON FH23 thermal unit, first disconnect power. Mount the unit onto the corresponding EATON contactor or starter base, ensuring proper alignment. Secure it according to the manufacturer's torque specifications. Always follow local electrical codes and consult the installation manual.

Used in

Common applications for EATON
Industrial control panels — Eaton M22 flush push buttons for momentary machine start/stop commands
Motor control centers — Eaton NEMA reversing starters with electronic overloads for conveyor belt direction control
HVAC systems — Eaton definite purpose starters with thermal overloads for compressor and fan motor protection
Process automation — Eaton SL7 tower lights with IP66 bases for visual status indication in wet environments
Machine tool signaling — Eaton 10250T LED pilot lights with push-to-test for operator panel status lamps
Access control — Eaton M22 keyed selector switches for equipment mode selection in secured areas

EATON Products

3G Electric supplies EATON electrical. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
EATON Thermal Unit: 20 Trip Class, FH22
EATON
EATON Thermal Unit: 20 Trip Class, FH22
EATON Thermal Unit: 20 Trip Class, FH21
EATON
EATON Thermal Unit: 20 Trip Class, FH21
The EATON FH33 is a thermal unit designed for overload protection in motor starters and contactors. It provides Class 20 trip protection, ensuring motors are safeguarded against overheating in industrial electrical systems
EATON
The EATON FH33 is a thermal unit designed for overload protection in motor starters and contactors. It provides Class 20 trip protection, ensuring motors are safeguarded against overheating in industrial electrical systems
EATON Thermal Unit: 20 Trip Class, FH03
EATON
EATON Thermal Unit: 20 Trip Class, FH03
Thermal overload protection device for motor starters and contactors. Provides Class 20 trip protection, tripping within 20 seconds at 600% of rated current. Used in industrial motor control applications to prevent thermal damage from sustained overloads
EATON
Thermal overload protection device for motor starters and contactors. Provides Class 20 trip protection, tripping within 20 seconds at 600% of rated current. Used in industrial motor control applications to prevent thermal damage from sustained overloads
EATON Thermal Unit: 20 Trip Class, FH13
EATON
EATON Thermal Unit: 20 Trip Class, FH13

More from EATON

View all EATON parts
Bimetallic overload relay element for motor starters and contactors. Provides 20 Trip Class response, tripping within 20 seconds at 600% of rated current to protect motors from sustained overcurrent conditions in industrial electrical systems
EATON
Bimetallic overload relay element for motor starters and contactors. Provides 20 Trip Class response, tripping within 20 seconds at 600% of rated current to protect motors from sustained overcurrent conditions in industrial electrical systems
Thermal overload protection device for use in motor starters and contactors. Designed to protect motors from sustained overcurrent by tripping the circuit when current exceeds the rated threshold. Features a 20 Trip Class, indicating the maximum time to trip under overload conditions
EATON
Thermal overload protection device for use in motor starters and contactors. Designed to protect motors from sustained overcurrent by tripping the circuit when current exceeds the rated threshold. Features a 20 Trip Class, indicating the maximum time to trip under overload conditions
This current transformer kit provides a 1000:5 ratio for measuring and monitoring electrical current in industrial power distribution systems. Designed for panel mount installation, it features integrated lugs for secure connections. Suitable for use in switchgear, motor control centers, and panelboards for metering and protection applications
EATON
This current transformer kit provides a 1000:5 ratio for measuring and monitoring electrical current in industrial power distribution systems. Designed for panel mount installation, it features integrated lugs for secure connections. Suitable for use in switchgear, motor control centers, and panelboards for metering and protection applications
The EATON FH30 is a bimetallic overload relay element designed for motor starters and contactors. It provides Class 20 trip protection, ensuring the device trips within 20 seconds at 600% of rated current. This thermal unit is used in industrial motor control applications to prevent thermal damage from sustained overloads
EATON
The EATON FH30 is a bimetallic overload relay element designed for motor starters and contactors. It provides Class 20 trip protection, ensuring the device trips within 20 seconds at 600% of rated current. This thermal unit is used in industrial motor control applications to prevent thermal damage from sustained overloads
Thermal unit for overload protection in motor starters and contactors. Provides Class 20 trip protection, tripping within 20 seconds at 600% of rated current to prevent motor overheating
EATON
Thermal unit for overload protection in motor starters and contactors. Provides Class 20 trip protection, tripping within 20 seconds at 600% of rated current to prevent motor overheating
Thermal overload unit for motor starters and contactors. Provides Class 20 trip protection, tripping within 20 seconds at 600% of rated current. Used to protect motors from sustained overcurrent conditions in industrial electrical systems
EATON
Thermal overload unit for motor starters and contactors. Provides Class 20 trip protection, tripping within 20 seconds at 600% of rated current. Used to protect motors from sustained overcurrent conditions in industrial electrical systems
The EATON C440-XCOM expansion module enables remote reset capability for C440 electronic overload relays. This allows operators to reset tripped overloads from a distance, reducing downtime in motor control applications such as conveyors, pumps, and fans
EATON
The EATON C440-XCOM expansion module enables remote reset capability for C440 electronic overload relays. This allows operators to reset tripped overloads from a distance, reducing downtime in motor control applications such as conveyors, pumps, and fans
Thermal unit for motor overload protection in starters and contactors. Responds to heat from sustained overcurrent to trip the circuit, safeguarding motor windings. 20 Trip Class rating
EATON
Thermal unit for motor overload protection in starters and contactors. Responds to heat from sustained overcurrent to trip the circuit, safeguarding motor windings. 20 Trip Class rating