We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

EATON Combination Starter: Fusible Disconnect, 3 Poles, NEMA Size 1, 575V AC - Fusible Starters with Electronic Overloads
EATONFusible Starters with Electronic Overloads

EATON Combination Starter: Fusible Disconnect, 3 Poles, NEMA Size 1, 575V AC

The EATON NEMA Combination Starter: Fusible Disconnect is a three-phase fusible starter with electronic overloads, part of the Freedom series. It features 3 poles, a NEMA Size 1 rating, and a coil voltage of 550/575V…

SKU 3G-OTH-40461

Also listed as: ECN1614DACR63D · ECN1614DAC R63 D · ECN1614DAC-R63-D

Brand
EATON
Item
Combination Starter: Fusible Disconnect, 3 Poles, NEMA Size 1, 575V AC
Category
Fusible Starters with Electronic Overloads
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

EATON
Manufacturer Part Number
ECN1614DAC-R63/D
Series
Freedom
Type
NEMA Size 1, NEMA-Rated 4X
AC
575V
Phase
Three
Poles
3
Poles/Phase
3 Pole / Three Phase
Coil Voltage
550/575V AC
Operator Type
No Operator
For Fuse Class
Class R
Control Transformer
No
Includes Pilot Light
No
Maximum Voltage Rating
600V AC
Thermal Units Required
None (Not Applicable to Electronic Overloads)
Terminal Connection Type
Screw Terminals
Includes Auxiliary Contacts
Yes

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

EATON Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The EATON NEMA Combination Starter: Fusible Disconnect is a three-phase fusible starter with electronic overloads, part of the Freedom series. It features 3 poles, a NEMA Size 1 rating, and a coil voltage of 550/575V AC, with a maximum voltage rating of 600V AC. This unit is designed for Class R fuses, includes screw terminals and auxiliary contacts, and is NEMA-rated 4X.

Frequently Asked Questions

What is the EATON NEMA Combination Starter used for?

The EATON NEMA Combination Starter is used for motor control and protection in industrial applications requiring a fusible disconnect. It handles three-phase motors up to 575V AC, with NEMA Size 1 rating and NEMA 4X enclosure for washdown or corrosive environments.

What are the specifications of the EATON ECN1614DAC-R63/D?

This EATON Freedom series starter has 3 poles, NEMA Size 1, coil voltage 550/575V AC, max voltage 600V AC, and accepts Class R fuses. It includes screw terminals and auxiliary contacts, with electronic overloads (no thermal units needed). NEMA-rated 4X enclosure.

Where to buy the EATON NEMA Combination Starter worldwide?

3G Electric supplies the EATON NEMA Combination Starter worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your site. Contact us to order the ECN1614DAC-R63/D with confidence.

How to select the right NEMA starter for a motor?

Select a NEMA starter by matching the motor's full-load current and voltage to the starter's NEMA size and coil voltage. For this EATON unit, NEMA Size 1 suits motors up to 27A at 575V AC. Verify enclosure type (NEMA 4X) for environmental exposure.

Used in

Common applications for EATON
Industrial control panels — Eaton M22 flush push buttons for momentary machine start/stop commands
Motor control centers — Eaton NEMA reversing starters with electronic overloads for conveyor belt direction control
HVAC systems — Eaton definite purpose starters with thermal overloads for compressor and fan motor protection
Process automation — Eaton SL7 tower lights with IP66 bases for visual status indication in wet environments
Machine tool signaling — Eaton 10250T LED pilot lights with push-to-test for operator panel status lamps
Access control — Eaton M22 keyed selector switches for equipment mode selection in secured areas

EATON Products

3G Electric supplies EATON fusible starters with electronic overloads. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Three-phase NEMA Size 1 fusible starter with electronic overload protection, rated 600V AC maximum and 575V AC coil voltage. Accepts Class R fuses and includes screw terminals and auxiliary contacts. Suitable for motor starting and branch-circuit protection in industrial environments requiring a NEMA 12 enclosure
EATON
Three-phase NEMA Size 1 fusible starter with electronic overload protection, rated 600V AC maximum and 575V AC coil voltage. Accepts Class R fuses and includes screw terminals and auxiliary contacts. Suitable for motor starting and branch-circuit protection in industrial environments requiring a NEMA 12 enclosure
EATON NEMA Combination Starter: Fusible Disconnect, 3 Poles, NEMA Size 1, 120V AC, NEMA-Rated 1 (MPN ECN1611AAB-R63/D)
EATON
EATON NEMA Combination Starter: Fusible Disconnect, 3 Poles, NEMA Size 1, 120V AC, NEMA-Rated 1 (MPN ECN1611AAB-R63/D)
EATON NEMA Combination Starter: Fusible Disconnect, 3 Poles, NEMA Size 2, 120V AC, NEMA-Rated 4X (MPN ECN1624AAD-R63/D)
EATON
EATON NEMA Combination Starter: Fusible Disconnect, 3 Poles, NEMA Size 2, 120V AC, NEMA-Rated 4X (MPN ECN1624AAD-R63/D)
EATON NEMA Combination Starter: Fusible Disconnect, 3 Poles, NEMA Size 1, 120V AC, NEMA-Rated 1 (MPN ECN1618DAC-R63/CL30)
EATON
EATON NEMA Combination Starter: Fusible Disconnect, 3 Poles, NEMA Size 1, 120V AC, NEMA-Rated 1 (MPN ECN1618DAC-R63/CL30)
EATON NEMA Combination Starter: Fusible Disconnect, 3 Poles, NEMA Size 4, 480V AC, NEMA-Rated 12 (MPN ECN1648CAJ-R63/F)
EATON
EATON NEMA Combination Starter: Fusible Disconnect, 3 Poles, NEMA Size 4, 480V AC, NEMA-Rated 12 (MPN ECN1648CAJ-R63/F)
Three-phase, three-pole NEMA Size 0 fusible starter with electronic overload, rated 240V AC and 600V AC maximum. Enclosed in a NEMA 3R rated enclosure. Coil voltage 220/240V AC. Accepts Class R fuses. Includes screw terminals and auxiliary contacts. No operator, pilot light, or control transformer
EATON
Three-phase, three-pole NEMA Size 0 fusible starter with electronic overload, rated 240V AC and 600V AC maximum. Enclosed in a NEMA 3R rated enclosure. Coil voltage 220/240V AC. Accepts Class R fuses. Includes screw terminals and auxiliary contacts. No operator, pilot light, or control transformer

More from EATON

View all EATON parts
Three-phase NEMA Size 3 fusible starter with electronic overload, rated 600V AC maximum. Coil voltage 110/120V AC, accepts Class R fuses. Includes screw terminals and auxiliary contacts. Suitable for motor starting and protection in industrial applications
EATON
Three-phase NEMA Size 3 fusible starter with electronic overload, rated 600V AC maximum. Coil voltage 110/120V AC, accepts Class R fuses. Includes screw terminals and auxiliary contacts. Suitable for motor starting and protection in industrial applications
Three-phase NEMA Size 2 fusible starter with electronic overload, rated 600V AC maximum. Features 208V AC coil voltage, Class R fuse acceptance, screw terminals, and auxiliary contacts. Suitable for motor starting and overload protection in industrial environments
EATON
Three-phase NEMA Size 2 fusible starter with electronic overload, rated 600V AC maximum. Features 208V AC coil voltage, Class R fuse acceptance, screw terminals, and auxiliary contacts. Suitable for motor starting and overload protection in industrial environments
Three-phase NEMA Size 1 fusible starter with electronic overload, rated for 600V AC maximum. Features 3 poles, 110/120V AC coil voltage, screw terminals, and auxiliary contacts. Accepts Class R fuses; no control transformer or pilot light included. Thermal units are not required due to electronic overload design
EATON
Three-phase NEMA Size 1 fusible starter with electronic overload, rated for 600V AC maximum. Features 3 poles, 110/120V AC coil voltage, screw terminals, and auxiliary contacts. Accepts Class R fuses; no control transformer or pilot light included. Thermal units are not required due to electronic overload design
Three-phase NEMA Size 0 fusible starter with electronic overload, rated 600V AC maximum. Includes auxiliary contacts and screw terminals; accepts Class R fuses. Coil voltage 208V AC. NEMA 3R enclosure suitable for outdoor or damp locations. Used for motor starting and protection in industrial control applications
EATON
Three-phase NEMA Size 0 fusible starter with electronic overload, rated 600V AC maximum. Includes auxiliary contacts and screw terminals; accepts Class R fuses. Coil voltage 208V AC. NEMA 3R enclosure suitable for outdoor or damp locations. Used for motor starting and protection in industrial control applications
Three-phase NEMA Size 2 fusible starter with electronic overload, part of the Freedom series. Rated 600V AC maximum, 120V AC control, with 440/460V AC coil. Includes control transformer (220/440V AC primary, 110V AC secondary), Start/Stop push buttons, pilot light, and auxiliary contacts. Accepts Class R fuses; screw terminal connections. Suitable for motor starting and protection in industrial environments
EATON
Three-phase NEMA Size 2 fusible starter with electronic overload, part of the Freedom series. Rated 600V AC maximum, 120V AC control, with 440/460V AC coil. Includes control transformer (220/440V AC primary, 110V AC secondary), Start/Stop push buttons, pilot light, and auxiliary contacts. Accepts Class R fuses; screw terminal connections. Suitable for motor starting and protection in industrial environments
Three-phase NEMA Size 5 fusible starter with electronic overload, part of the Freedom series. Rated for 600V AC maximum, with a 110/120V AC coil. Includes auxiliary contacts and screw terminals. Designed for Class R fuses. Suitable for motor control and protection in industrial environments requiring a NEMA 4X enclosure
EATON
Three-phase NEMA Size 5 fusible starter with electronic overload, part of the Freedom series. Rated for 600V AC maximum, with a 110/120V AC coil. Includes auxiliary contacts and screw terminals. Designed for Class R fuses. Suitable for motor control and protection in industrial environments requiring a NEMA 4X enclosure
Three-phase fusible starter with electronic overload, NEMA Size 2, rated 600V AC maximum. Includes auxiliary contacts and screw terminals. Coil voltage 220/240V AC, accepts Class R fuses. Suitable for motor starting and overload protection in industrial applications
EATON
Three-phase fusible starter with electronic overload, NEMA Size 2, rated 600V AC maximum. Includes auxiliary contacts and screw terminals. Coil voltage 220/240V AC, accepts Class R fuses. Suitable for motor starting and overload protection in industrial applications
Three-phase fusible starter with electronic overload, part of the Freedom series. NEMA Size 00, 3 poles, coil voltage 110/120V AC, maximum voltage 600V AC. Accepts Class R fuses. Includes screw terminals and auxiliary contacts. No operator, control transformer, or pilot light. Used for starting and stopping three-phase motors with overcurrent protection in industrial motor control applications
EATON
Three-phase fusible starter with electronic overload, part of the Freedom series. NEMA Size 00, 3 poles, coil voltage 110/120V AC, maximum voltage 600V AC. Accepts Class R fuses. Includes screw terminals and auxiliary contacts. No operator, control transformer, or pilot light. Used for starting and stopping three-phase motors with overcurrent protection in industrial motor control applications