We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

Dwyer V6EPB-B-S-2-B Inline Hazardous-Location Liquid Flow Switch - Inline Hazardous-Location Switches for Liquids
DwyerInline Hazardous-Location Switches for Liquids

Dwyer V6EPB-B-S-2-B Inline Hazardous-Location Liquid Flow Switch

The DWYER Liquid Flow Switch: Paddle is an inline hazardous-location switch for liquids, designed for pipe sizes of 1/2 in. It carries a hazardous location rating of Class II, Div 1 and 2, Group E, F, G, and offers a…

SKU 3G-OTH-89579

Also listed as: V6EPBBS2B · V6EPB B S 2 B

Brand
Dwyer
Item
V6EPB-B-S-2-B Inline Hazardous-Location Liquid Flow Switch
Category
Inline Hazardous-Location Switches for Liquids
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

Dwyer
Manufacturer Part Number
V6EPB-B-S-2-B
Type
1/2 in/1/4 in/2 in/3/8 in For Pipe Size, Brass, NPT
NPT
3/4 in
For Pipe Size
1/2 in
Contact Rating (AC)
5 A @ 125/250V
Contact Rating (DC)
20 A (Inductive) @ 30V (CSA, ATEX and IECEx Models)
Hazardous Location Rating
Class II, Div 1 and 2, Group E, F, G

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Dwyer Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The DWYER Liquid Flow Switch: Paddle is an inline hazardous-location switch for liquids, designed for pipe sizes of 1/2 in. It carries a hazardous location rating of Class II, Div 1 and 2, Group E, F, G, and offers a contact rating of 5 A @ 125/250V AC, with a DC rating of 20 A (Inductive) @ 30V for CSA, ATEX and IECEx models.

Frequently Asked Questions

What is the DWYER V6EPB-B-S-2-B liquid flow switch used for?

The DWYER V6EPB-B-S-2-B is a paddle-type liquid flow switch designed for hazardous locations rated Class II, Div 1 and 2, Groups E, F, G. It detects flow or no-flow conditions in pipes of 1/2 inch size, commonly used in industrial processes, oil and gas, and chemical plants where flammable dust or vapors are present.

What are the specifications of the DWYER V6EPB-B-S-2-B flow switch?

The DWYER V6EPB-B-S-2-B has a contact rating of 5 A @ 125/250V AC and 20 A (Inductive) @ 30V DC for CSA, ATEX, and IECEx models. It fits a 1/2 inch pipe size with a 3/4 inch NPT connection, brass body, and carries a hazardous location rating of Class II, Div 1 and 2, Group E, F, G.

Where to buy the DWYER V6EPB-B-S-2-B flow switch worldwide?

You can source the DWYER V6EPB-B-S-2-B flow switch worldwide through 3G Electric, a global industrial equipment distributor. We handle full logistics, customs clearance, and delivery to your location. Contact us for availability and lead time; we provide competitive pricing and reliable sourcing for this Dwyer product.

How to install the DWYER V6EPB-B-S-2-B paddle flow switch?

Install the DWYER V6EPB-B-S-2-B in a horizontal pipe section with the paddle oriented correctly for flow direction. Ensure the 3/4 inch NPT connection is sealed with appropriate thread sealant. For hazardous locations, follow local electrical codes and verify the switch is wired to a suitable power source within its 5 A AC or 20 A DC rating.

Used in

Common applications for Dwyer
Combustion air-filter monitoring — Magnehelic Series 2000 on burner air-intake filter banks
Clean-room and pharmaceutical pressurisation — Magnehelic / Capsuhelic differential-pressure gauges
HVAC fan-discharge static pressure — Mark II inclined-vertical manometers on AHU test points
Filter-blockage alarms — Photohelic Series 3000 combined gauge/switch on air-handling units
BMS-integrated pressure monitoring — Digihelic DH3 with 4–20 mA output for building management

Dwyer Products

3G Electric supplies Dwyer inline hazardous-location switches for liquids. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Inline paddle flow switch for liquid flow detection in hazardous locations. Brass body with 1 1/2 in NPT connections, for 3/8 in pipe size. Rated Class I, Div 1 and 2, Groups A, B, C, D. AC contact rating 5 A @ 125/250V; DC contact rating 5 A resistive @ 30V (CSA, ATEX and IECEx models)
Dwyer
Inline paddle flow switch for liquid flow detection in hazardous locations. Brass body with 1 1/2 in NPT connections, for 3/8 in pipe size. Rated Class I, Div 1 and 2, Groups A, B, C, D. AC contact rating 5 A @ 125/250V; DC contact rating 5 A resistive @ 30V (CSA, ATEX and IECEx models)
This inline paddle flow switch detects liquid flow or no-flow conditions in 2-inch pipes. Brass body with 2 in NPT connection. Rated for hazardous locations: Class I, Divisions 1 and 2, Groups A, B, C, D. AC contact rating 5 A at 125/250V; DC inductive rating 15 A at 30V for CSA, ATEX, and IECEx models. Suitable for use in environments with flammable gases or vapors
Dwyer
This inline paddle flow switch detects liquid flow or no-flow conditions in 2-inch pipes. Brass body with 2 in NPT connection. Rated for hazardous locations: Class I, Divisions 1 and 2, Groups A, B, C, D. AC contact rating 5 A at 125/250V; DC inductive rating 15 A at 30V for CSA, ATEX, and IECEx models. Suitable for use in environments with flammable gases or vapors
Brass-bodied paddle flow switch for 1/4 in pipe with 1/2 in NPT connection. Rated for hazardous locations Class II, Div 1 and 2, Groups E, F, G. AC contact rating 5 A at 125/250V; DC contact rating 19 A inductive at 30V (CSA, ATEX, IECEx models). Used to detect flow or no-flow conditions in liquid lines
Dwyer
Brass-bodied paddle flow switch for 1/4 in pipe with 1/2 in NPT connection. Rated for hazardous locations Class II, Div 1 and 2, Groups E, F, G. AC contact rating 5 A at 125/250V; DC contact rating 19 A inductive at 30V (CSA, ATEX, IECEx models). Used to detect flow or no-flow conditions in liquid lines
This inline paddle-type flow switch detects flow or no-flow conditions in liquid piping systems. It is rated for Class I, Div 1 and 2, Groups A, B, C, D hazardous locations. The brass body has a 1 1/4 in NPT connection and fits 3/8 in pipe. Contact rating is 5 A at 125/250 VAC and 5 A resistive at 30 VDC (CSA, ATEX, IECEx models)
Dwyer
This inline paddle-type flow switch detects flow or no-flow conditions in liquid piping systems. It is rated for Class I, Div 1 and 2, Groups A, B, C, D hazardous locations. The brass body has a 1 1/4 in NPT connection and fits 3/8 in pipe. Contact rating is 5 A at 125/250 VAC and 5 A resistive at 30 VDC (CSA, ATEX, IECEx models)
This inline flow switch detects flow or no-flow conditions in hazardous locations rated Class II, Div 1 and 2, Groups E, F, G. It features a brass body with 1/2 in NPT connection for 3/8 in pipe size. Contact rating is 5 A at 125/250 V AC and 18 A inductive at 30 V DC (CSA, ATEX, IECEx models). Suitable for use with combustible dusts in industrial processes
Dwyer
This inline flow switch detects flow or no-flow conditions in hazardous locations rated Class II, Div 1 and 2, Groups E, F, G. It features a brass body with 1/2 in NPT connection for 3/8 in pipe size. Contact rating is 5 A at 125/250 V AC and 18 A inductive at 30 V DC (CSA, ATEX, IECEx models). Suitable for use with combustible dusts in industrial processes
This inline paddle-type flow switch is rated for hazardous locations Class I, Div 1 and 2, Groups A, B, C, D. It features a brass body with 2 in NPT connection and is designed for 1/4 in pipe size. Contact rating is 5 A at 125/250V AC, and 16 A inductive at 30V DC for CSA, ATEX, and IECEx models. Used to detect flow or no-flow conditions in liquid piping systems
Dwyer
This inline paddle-type flow switch is rated for hazardous locations Class I, Div 1 and 2, Groups A, B, C, D. It features a brass body with 2 in NPT connection and is designed for 1/4 in pipe size. Contact rating is 5 A at 125/250V AC, and 16 A inductive at 30V DC for CSA, ATEX, and IECEx models. Used to detect flow or no-flow conditions in liquid piping systems

More from Dwyer

View all Dwyer parts
This inline switch is designed for hazardous locations where liquid flow detection is required. It features a brass body with a 1 1/2 in NPT connection and fits 3/4 in female NPT pipe. The switch has a contact rating of 10 A at 125/250V AC and 3 A at 30V DC (inductive). Typical applications include flow monitoring in industrial piping systems where explosion-proof protection is necessary
Dwyer
This inline switch is designed for hazardous locations where liquid flow detection is required. It features a brass body with a 1 1/2 in NPT connection and fits 3/4 in female NPT pipe. The switch has a contact rating of 10 A at 125/250V AC and 3 A at 30V DC (inductive). Typical applications include flow monitoring in industrial piping systems where explosion-proof protection is necessary
This inline paddle-type flow switch detects flow or no-flow conditions in liquid pipes of 1/2 in size. Constructed with brass and a 3/4 in NPT connection, it is rated for hazardous locations Class II, Div 1 and 2, Groups E, F, G. Contact rating is 5 A at 125/250V AC and 5 A resistive at 30V DC for CSA, ATEX, and IECEx models
Dwyer
This inline paddle-type flow switch detects flow or no-flow conditions in liquid pipes of 1/2 in size. Constructed with brass and a 3/4 in NPT connection, it is rated for hazardous locations Class II, Div 1 and 2, Groups E, F, G. Contact rating is 5 A at 125/250V AC and 5 A resistive at 30V DC for CSA, ATEX, and IECEx models
This inline paddle-type flow switch detects flow or no-flow conditions in liquid systems. It features a brass body with 3/4 in NPT connection for 2 in pipe size. Rated for hazardous locations Class I, Div 1 and 2, Groups A, B, C, D. Contact rating: 5 A @ 125/250V AC; 5 A resistive @ 30V DC (CSA, ATEX, IECEx models)
Dwyer
This inline paddle-type flow switch detects flow or no-flow conditions in liquid systems. It features a brass body with 3/4 in NPT connection for 2 in pipe size. Rated for hazardous locations Class I, Div 1 and 2, Groups A, B, C, D. Contact rating: 5 A @ 125/250V AC; 5 A resistive @ 30V DC (CSA, ATEX, IECEx models)
Inline paddle flow switch for detecting liquid flow or no-flow conditions in 2-inch pipes. Brass body with 1-inch NPT connection. Rated for Class II, Division 1 and 2, Groups E, F, G hazardous locations. AC contact rating 5 A at 125/250V; DC inductive rating 23 A at 30V (CSA, ATEX, IECEx models)
Dwyer
Inline paddle flow switch for detecting liquid flow or no-flow conditions in 2-inch pipes. Brass body with 1-inch NPT connection. Rated for Class II, Division 1 and 2, Groups E, F, G hazardous locations. AC contact rating 5 A at 125/250V; DC inductive rating 23 A at 30V (CSA, ATEX, IECEx models)
This inline paddle-type flow switch detects flow or no-flow conditions in liquid piping systems. It is rated for hazardous locations Class I, Div 1 and 2, Groups A, B, C, D. The switch has a 5 A @ 125/250V AC and 5 A resistive @ 30V DC contact rating (CSA, ATEX, IECEx models). Constructed with stainless steel and 1/2 in, 1/4 in, 3/8 in NPT connections for 2 in pipe size
Dwyer
This inline paddle-type flow switch detects flow or no-flow conditions in liquid piping systems. It is rated for hazardous locations Class I, Div 1 and 2, Groups A, B, C, D. The switch has a 5 A @ 125/250V AC and 5 A resistive @ 30V DC contact rating (CSA, ATEX, IECEx models). Constructed with stainless steel and 1/2 in, 1/4 in, 3/8 in NPT connections for 2 in pipe size
This inline paddle flow switch is designed for liquid flow detection in 1/4-inch NPT pipe systems. Constructed with stainless steel, it is rated for hazardous locations Class I, Division 1 and 2, Groups A, B, C, D. AC contact rating is 5 A at 125/250V; DC inductive rating is 40 A at 30V for CSA, ATEX and IECEx models. Suitable for use in industrial fluid systems requiring explosion-proof monitoring
Dwyer
This inline paddle flow switch is designed for liquid flow detection in 1/4-inch NPT pipe systems. Constructed with stainless steel, it is rated for hazardous locations Class I, Division 1 and 2, Groups A, B, C, D. AC contact rating is 5 A at 125/250V; DC inductive rating is 40 A at 30V for CSA, ATEX and IECEx models. Suitable for use in industrial fluid systems requiring explosion-proof monitoring
This inline paddle flow switch detects liquid flow or no-flow conditions in pipes. Constructed with stainless steel, it is rated for hazardous locations Class II, Div 1 and 2, Groups E, F, G. Suitable for 3/8 in pipe size with a 2 in NPT connection. Contact ratings: 5 A at 125/250 VAC, and 5 A resistive at 30 VDC (CSA, ATEX, IECEx models)
Dwyer
This inline paddle flow switch detects liquid flow or no-flow conditions in pipes. Constructed with stainless steel, it is rated for hazardous locations Class II, Div 1 and 2, Groups E, F, G. Suitable for 3/8 in pipe size with a 2 in NPT connection. Contact ratings: 5 A at 125/250 VAC, and 5 A resistive at 30 VDC (CSA, ATEX, IECEx models)
Inline paddle flow switch for liquids in hazardous locations. Brass body with 1 in NPT connection for 2 in pipe size. Rated Class I, Div 1 and 2, Groups A, B, C, D. Contact ratings: 5 A @ 125/250V AC, 5 A resistive @ 30V DC (CSA, ATEX, IECEx models). Used to detect flow or no-flow conditions in piping systems
Dwyer
Inline paddle flow switch for liquids in hazardous locations. Brass body with 1 in NPT connection for 2 in pipe size. Rated Class I, Div 1 and 2, Groups A, B, C, D. Contact ratings: 5 A @ 125/250V AC, 5 A resistive @ 30V DC (CSA, ATEX, IECEx models). Used to detect flow or no-flow conditions in piping systems