We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

3G Electric
Image not available
DungsBurner control

DUNGS FLW 2x UV - UV-Flame Sensors

The DUNGS flame scanner FLW 2x UV are used for optical flame detection in the ultraviolet spectrum. These compact flame scanners are suitable for intermittent operation.

SKU 3G-OTH-02882

Also listed as: FLW2XUV · FLW 2X UV

Brand
Dungs
Item
FLW 2x UV - UV-Flame Sensors
Part Number
FLW-2X-UV
Category
Burner control
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Dungs Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The DUNGS flame scanner FLW 2x UV are used for optical flame detection in the ultraviolet spectrum. These compact flame scanners are suitable for intermittent operation.

Frequently Asked Questions

What is the DUNGS FLW 2x UV flame sensor used for?

The DUNGS FLW 2x UV is a flame scanner used for optical flame detection in the ultraviolet spectrum. It is designed for intermittent operation in industrial burner control systems, providing reliable UV sensing to verify burner flame presence and ensure safe combustion in boilers, furnaces, and process heaters.

What are the specifications of the DUNGS FLW 2x UV?

The DUNGS FLW 2x UV is a compact UV-flame sensor from Karl Dungs GmbH & Co. KG, suitable for intermittent operation. It detects flames in the ultraviolet spectrum for burner control applications. For detailed technical specifications such as voltage, current, or temperature ratings, please refer to the manufacturer datasheet or contact 3G Electric.

Where to buy DUNGS FLW 2x UV in Singapore?

You can source the DUNGS FLW 2x UV flame sensor through 3G Electric in Singapore. We supply genuine Dungs burner control components and handle logistics, customs clearance, and delivery to your facility. Contact us for pricing and lead time on this UV flame scanner.

How to install the DUNGS FLW 2x UV flame sensor?

Install the DUNGS FLW 2x UV sensor by mounting it in a position with a clear line of sight to the burner flame, following the manufacturer's guidelines. Ensure proper electrical connections per the wiring diagram and verify UV detection range. For intermittent operation, the sensor should be integrated with the burner control system. Consult a qualified technician.

Used in

Common applications for Dungs
Industrial steam boilers — MB-ZRDLE MultiBloc on modulating gas-fired plant
Hospital and hotel plant rooms — MB-D series for two-stage commercial burners
Food-industry ovens and dryers — DMV butterfly valves on high-turndown modulating lines
Petrochemical gas-train skid assemblies — FRS / FRSBV regulators with GW pressure switches
Retrofit drop-in replacements for older Dungs MB assemblies on existing Weishaupt / Riello burners
Not sure this is the right part? Photo-identify it

Dungs Products

3G Electric supplies Dungs burner control. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Fireye
Fireye
UV1AL Series UV Flame Scanners
UV1A Series UV Flame Scanners. The UV tube is made of quartz and is filled with a gas that ionizes when struck by UV radiation from the flame. In the absence of UV radiation, the gas acts as an insulator between two electrodes that are mounted inside the tube. These electrodes are energized continuously by a high voltage. During combustion, UV radiation ionizes the gas, causing current pulses to flow between the electrodes. These current pulses result in a flame signal which is transmitted to the amplifier in the control, where it is processed to energize or hold in the flame relay
Fireye
UV1A Series UV Flame Scanners. The UV tube is made of quartz and is filled with a gas that ionizes when struck by UV radiation from the flame. In the absence of UV radiation, the gas acts as an insulator between two electrodes that are mounted inside the tube. These electrodes are energized continuously by a high voltage. During combustion, UV radiation ionizes the gas, causing current pulses to flow between the electrodes. These current pulses result in a flame signal which is transmitted to the amplifier in the control, where it is processed to energize or hold in the flame relay
UV cell UVS 10D1G1
Kromschroder
UV cell UVS 10D1G1
UV90L Series UV Flame Scanners. The UV scanner is ideally suited for gaseous fuels (natural gas & propane). However, it can be used in detecting flames from standard fuel gases, some waste gases and light oil fuels such as No. 2 oil. Flames from heavier oils can be detected with UV scanners but the unburned fuel shroud and/or atomization shroud can block the passage of the UV from the flame zone to the UV tube, causing nuisance burner/boiler trips. Infrared detection is recommended for fuel oil heavier than No. 2, and some installations where waste gases are burned together with natural gas as the main flame
Fireye
UV90L Series UV Flame Scanners. The UV scanner is ideally suited for gaseous fuels (natural gas & propane). However, it can be used in detecting flames from standard fuel gases, some waste gases and light oil fuels such as No. 2 oil. Flames from heavier oils can be detected with UV scanners but the unburned fuel shroud and/or atomization shroud can block the passage of the UV from the flame zone to the UV tube, causing nuisance burner/boiler trips. Infrared detection is recommended for fuel oil heavier than No. 2, and some installations where waste gases are burned together with natural gas as the main flame
High sensitivity UV bulb
Satronic
High sensitivity UV bulb
Fireye
Fireye
UV8A Series UV Flame Scanners. The UV8A Scanner is a 90° right-angle ultraviolet flame scanner designed for reliable flame detection. Compatible with M-Series, M-Series II, MicroM, FlameWorx, MB-2, D series controls, as well as Fireye® FLAME-MONITOR, BurnerLogix, and the Nexus System, the UV8A offers versatile integration for various burner management systems

More from Dungs

View all Dungs parts
Dungs
Dungs
DUNGS FLW 1x IR - IR-Flame Sensors
DUNGS MPA 41xx V2.0 - Automatic Burner Controls
Dungs
DUNGS MPA 41xx V2.0 - Automatic Burner Controls

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first