We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

DRAEGER Gas Detection Tube for Accuro Pumps - Gas Detection Tubes For Use In DRAEGER Accuro Pumps
DRAEGERGas Detection Tubes For Use In DRAEGER Accuro Pumps

DRAEGER Gas Detection Tube for Accuro Pumps

The DRAEGER Detector Tube for Accuro pumps detects water vapor (H2O) with a measurement range of 0.1 to 1 mg/L, supplied in a 10-pack (MPN 8101321). 3G Electric interprets this demand and delivers the genuine DRAEGER…

SKU 3G-OTH-548670

Brand
DRAEGER
Item
Gas Detection Tube for Accuro Pumps
Category
Gas Detection Tubes For Use In DRAEGER Accuro Pumps
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

DRAEGER
Manufacturer Part Number
8101321
Type
H2O, Gas Detection Tube, Water Vapor ( H2O ), 10 PK
Gas Detected
Water Vapor
Measurement Range
0.1 to 1 mg/L

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

DRAEGER Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The DRAEGER Detector Tube for Accuro pumps detects water vapor (H2O) with a measurement range of 0.1 to 1 mg/L, supplied in a 10-pack (MPN 8101321). 3G Electric interprets this demand and delivers the genuine DRAEGER tube across 14 industrial departments — with specialist depth in combustion, pumps and controls as an authorised distributor for brands like FBR, Interpump, Riello, Beckett, Schneider, ABB, Siemens, SKF, Festo, and Fluke.

Frequently Asked Questions

What is the DRAEGER detector tube 8101321 used for?

The DRAEGER detector tube 8101321 is used with Accuro pumps to measure water vapor (H2O) concentration in air or gas streams. It is commonly applied in industrial hygiene, environmental monitoring, and process control where moisture levels between 0.1 and 1 mg/L must be verified.

What are the specifications of the DRAEGER water vapor detector tube?

This DRAEGER tube detects water vapor (H2O) with a measurement range of 0.1 to 1 mg/L. It is supplied in a 10-pack, manufacturer part number 8101321, and is designed for use with DRAEGER Accuro pumps. The tube provides a direct-reading colorimetric indication.

Where to buy DRAEGER detector tubes for Accuro pumps worldwide?

3G Electric supplies genuine DRAEGER detector tubes worldwide. We handle full logistics, customs clearance, and delivery to your site. As a global industrial solutions provider, we source across 14 departments including combustion, pumps, and controls, with specialist depth in brands like Schneider, ABB, and Siemens.

How to use the DRAEGER Accuro tube for water vapor measurement?

Break off both tips of the DRAEGER tube, insert it into the Accuro pump with the arrow pointing toward the pump, and pull the handle to draw a sample. Follow the pump stroke count and time specified on the tube label. Read the color change length against the printed scale to determine H2O concentration in mg/L.

DRAEGER Products

3G Electric supplies DRAEGER gas detection tubes for use in draeger accuro pumps. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Pump Accessories Valves & Regulation Motors & Drives All Products

More from DRAEGER

View all DRAEGER parts
This 10-pack of gas detection tubes is designed for use with DRAEGER Accuro pumps to detect phosphine in acetylene. It operates at a maximum temperature of 104°F and offers two measurement ranges: 1 to 15 ppm and 0.11 to 1 ppm. Suitable for industrial gas monitoring applications where acetylene is handled
DRAEGER
This 10-pack of gas detection tubes is designed for use with DRAEGER Accuro pumps to detect phosphine in acetylene. It operates at a maximum temperature of 104°F and offers two measurement ranges: 1 to 15 ppm and 0.11 to 1 ppm. Suitable for industrial gas monitoring applications where acetylene is handled
This 10-pack of gas detection tubes is designed for use with DRAEGER Accuro bellows pumps to measure hydrocyanic acid (HCN) concentrations in air. The tubes provide colorimetric indication across two measurement ranges: 0.5 to 5 ppm and 5 to 50 ppm. Typical applications include industrial hygiene monitoring and chemical processing safety checks
DRAEGER
This 10-pack of gas detection tubes is designed for use with DRAEGER Accuro bellows pumps to measure hydrocyanic acid (HCN) concentrations in air. The tubes provide colorimetric indication across two measurement ranges: 0.5 to 5 ppm and 5 to 50 ppm. Typical applications include industrial hygiene monitoring and chemical processing safety checks
Gas detection tube for use with DRAEGER Accuro pumps. Detects organic basic nitrogen with a measurement range of 1 mg/m3. Pack of 10 tubes. Suitable for on-site air analysis in industrial hygiene and environmental monitoring applications
DRAEGER
Gas detection tube for use with DRAEGER Accuro pumps. Detects organic basic nitrogen with a measurement range of 1 mg/m3. Pack of 10 tubes. Suitable for on-site air analysis in industrial hygiene and environmental monitoring applications
Gas detection tube for measuring mercury vapor (Hg) in air. Measurement range 0.05 to 2 mg/m³. Pack of 10 tubes. For use with DRAEGER Accuro pumps. Suitable for industrial hygiene and environmental monitoring applications
DRAEGER
Gas detection tube for measuring mercury vapor (Hg) in air. Measurement range 0.05 to 2 mg/m³. Pack of 10 tubes. For use with DRAEGER Accuro pumps. Suitable for industrial hygiene and environmental monitoring applications
Qualitative gas detection tube for use with DRAEGER Accuro pumps. Detects Hydrogen Acid with a 3-minute measurement time. Maximum operating temperature 86°F. Supplied in a 10-pack
DRAEGER
Qualitative gas detection tube for use with DRAEGER Accuro pumps. Detects Hydrogen Acid with a 3-minute measurement time. Maximum operating temperature 86°F. Supplied in a 10-pack
Gas detection tube for phosphoric acid ethers. Measurement range: 0.05 ppm. Maximum operating temperature: 104°F. Pack of 10. For use with DRAEGER Accuro pumps in industrial safety applications
DRAEGER
Gas detection tube for phosphoric acid ethers. Measurement range: 0.05 ppm. Maximum operating temperature: 104°F. Pack of 10. For use with DRAEGER Accuro pumps in industrial safety applications
This DRAEGER gas detection tube is designed for use with Accuro pumps to measure carbon monoxide (CO) concentrations. It covers two measurement ranges: 100 to 700 ppm and 5 to 150 ppm. Suitable for on-site gas detection in industrial environments, such as confined spaces or combustion areas
DRAEGER
This DRAEGER gas detection tube is designed for use with Accuro pumps to measure carbon monoxide (CO) concentrations. It covers two measurement ranges: 100 to 700 ppm and 5 to 150 ppm. Suitable for on-site gas detection in industrial environments, such as confined spaces or combustion areas
Gas detection tube for use with DRAEGER Accuro pumps. Detects hydrochloric acid (HCl) in the range of 1 to 10 ppm. Supplied in a pack of 10 tubes. Suitable for on-the-spot measurement of HCl concentrations in industrial environments
DRAEGER
Gas detection tube for use with DRAEGER Accuro pumps. Detects hydrochloric acid (HCl) in the range of 1 to 10 ppm. Supplied in a pack of 10 tubes. Suitable for on-the-spot measurement of HCl concentrations in industrial environments