We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

3G Electric
DRAEGER Gas Detection Tube for Accuro Pumps - Gas Detection Tubes For Use In DRAEGER Accuro Pumps
DRAEGERGas Detection Tubes For Use In DRAEGER Accuro Pumps

DRAEGER Gas Detection Tube for Accuro Pumps

The DRAEGER Detector Tube for Accuro pumps is a gas detection tube designed for use with DRAEGER Accuro pumps, detecting Ethylene Oxide (C2H4O) with a measurement range of 25 to 500 ppm. Supplied in a pack of 10 (MPN…

SKU 3G-OTH-548098

Brand
DRAEGER
Item
Gas Detection Tube for Accuro Pumps
Part Number
6728241
Category
Gas Detection Tubes For Use In DRAEGER Accuro Pumps
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

DRAEGER
Manufacturer Part Number
6728241
Type
C2H4O, Gas Detection Tube, Ethylene Oxide ( C2H4O ), 10 PK
Gas Detected
Ethylene Oxide
Measurement Range
25 to 500 ppm

Technical Documents

No technical documents available for this product.
Request documentation →
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

DRAEGER Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The DRAEGER Detector Tube for Accuro pumps is a gas detection tube designed for use with DRAEGER Accuro pumps, detecting Ethylene Oxide (C2H4O) with a measurement range of 25 to 500 ppm. Supplied in a pack of 10 (MPN 6728241), this product supports accurate gas detection in industrial environments.

Frequently Asked Questions

What is the DRAEGER Accuro C2H4O detector tube used for?

The DRAEGER Accuro C2H4O detector tube is used to measure ethylene oxide gas concentrations in industrial environments. It works with DRAEGER Accuro pumps to detect levels from 25 to 500 ppm, supporting safety monitoring in sterilization, chemical processing, and healthcare applications.

What are the specifications of the DRAEGER 6728241 gas detection tube?

The DRAEGER 6728241 detector tube detects ethylene oxide (C2H4O) with a measurement range of 25 to 500 ppm. It is supplied in a pack of 10 and is designed for use with DRAEGER Accuro pumps. This tube provides reliable gas detection for industrial safety.

Where to buy DRAEGER Accuro gas detection tubes worldwide?

3G Electric supplies DRAEGER Accuro gas detection tubes worldwide, handling logistics, customs, and delivery. As a global industrial solutions provider, we source genuine DRAEGER detector tubes like the 6728241 for ethylene oxide detection. Contact us for availability and lead time.

How to use the DRAEGER Accuro tube for ethylene oxide detection?

To use the DRAEGER Accuro tube for ethylene oxide detection, insert the tube into the Accuro pump, break off both tips, and follow the pump stroke instructions. The tube changes color to indicate concentration from 25 to 500 ppm. Always refer to the manufacturer's manual for safe operation.

Not sure this is the right part? Photo-identify it→

DRAEGER Products

3G Electric supplies DRAEGER gas detection tubes for use in draeger accuro pumps. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Pump Accessories →Valves & Regulation →Motors & Drives →All Products →

More from DRAEGER

View all DRAEGER parts →
Gas detection tube for use with DRAEGER Accuro pumps. Detects ethylene (C2H4) in a measurement range of 0.2 to 5 ppm. Supplied in a pack of 10 tubes. Suitable for spot-checking ethylene concentrations in industrial environments such as chemical processing or refrigeration
DRAEGER
Gas detection tube for use with DRAEGER Accuro pumps. Detects ethylene (C2H4) in a measurement range of 0.2 to 5 ppm. Supplied in a pack of 10 tubes. Suitable for spot-checking ethylene concentrations in industrial environments such as chemical processing or refrigeration
Gas detection tube for use with DRAEGER Accuro pumps. Detects oil mist in the range of 1 to 10 mg/m3. Maximum operating temperature 86°F. Pack of 10 tubes. Suitable for industrial air monitoring in environments where oil mist may be present
DRAEGER
Gas detection tube for use with DRAEGER Accuro pumps. Detects oil mist in the range of 1 to 10 mg/m3. Maximum operating temperature 86°F. Pack of 10 tubes. Suitable for industrial air monitoring in environments where oil mist may be present
Gas detection tube for use with DRAEGER Accuro pumps. Detects methylene chloride (CH2Cl2) in air over a measurement range of 20 to 200 ppm. Maximum operating temperature 86°F. Pack of 10 tubes. Suitable for spot-checking airborne solvent concentrations in industrial environments
DRAEGER
Gas detection tube for use with DRAEGER Accuro pumps. Detects methylene chloride (CH2Cl2) in air over a measurement range of 20 to 200 ppm. Maximum operating temperature 86°F. Pack of 10 tubes. Suitable for spot-checking airborne solvent concentrations in industrial environments
This 10-pack of gas detection tubes is designed for use with DRAEGER Accuro pumps. Each tube detects diethyl ether ((C2H5)2O) within a measurement range of 100 to 4,000 ppm and operates at temperatures up to 104°F. Suitable for industrial safety monitoring where diethyl ether may be present
DRAEGER
This 10-pack of gas detection tubes is designed for use with DRAEGER Accuro pumps. Each tube detects diethyl ether ((C2H5)2O) within a measurement range of 100 to 4,000 ppm and operates at temperatures up to 104°F. Suitable for industrial safety monitoring where diethyl ether may be present
Gas detection tube for use with DRAEGER Accuro pumps. Detects hydrochloric acid (HCl) in the range of 1 to 10 ppm. Supplied in a pack of 10 tubes. Suitable for on-the-spot measurement of HCl concentrations in industrial environments
DRAEGER
Gas detection tube for use with DRAEGER Accuro pumps. Detects hydrochloric acid (HCl) in the range of 1 to 10 ppm. Supplied in a pack of 10 tubes. Suitable for on-the-spot measurement of HCl concentrations in industrial environments
DRAEGER CS2 gas detection tube for use with Accuro pumps. Detects carbon disulfide (CS2) in the range of 3 to 95 ppm. Pack of 10 tubes. Suitable for industrial safety monitoring in environments where carbon disulfide may be present
DRAEGER
DRAEGER CS2 gas detection tube for use with Accuro pumps. Detects carbon disulfide (CS2) in the range of 3 to 95 ppm. Pack of 10 tubes. Suitable for industrial safety monitoring in environments where carbon disulfide may be present
Qualitative gas detection tube for use with DRAEGER Accuro pumps. Detects Hydrogen Acid with a 3-minute measurement time. Maximum operating temperature 86°F. Supplied in a 10-pack
DRAEGER
Qualitative gas detection tube for use with DRAEGER Accuro pumps. Detects Hydrogen Acid with a 3-minute measurement time. Maximum operating temperature 86°F. Supplied in a 10-pack
This 10-pack of gas detection tubes is designed for use with DRAEGER Accuro pumps to measure hydrogen sulfide (H2S) concentrations in ambient air. Each tube provides a colorimetric indication over a measurement range of 2 to 60 ppm. Typical applications include monitoring toxic gas exposure in industrial environments such as refineries, chemical plants, and confined spaces
DRAEGER
This 10-pack of gas detection tubes is designed for use with DRAEGER Accuro pumps to measure hydrogen sulfide (H2S) concentrations in ambient air. Each tube provides a colorimetric indication over a measurement range of 2 to 60 ppm. Typical applications include monitoring toxic gas exposure in industrial environments such as refineries, chemical plants, and confined spaces

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first