We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

Dayton Panel Exhaust Fan: Direct Drive, 12 in Blade, 1/4 hp, 1,347 cfm, 208-230/460V AC - Hazardous Location Direct-Drive Panel Exhaust Fans
DaytonHazardous Location Direct-Drive Panel Exhaust Fans

Dayton Panel Exhaust Fan: Direct Drive, 12 in Blade, 1/4 hp, 1,347 cfm, 208-230/460V AC

The Dayton is a hazardous location direct-drive panel exhaust fan with a 12-inch blade, 1/4 hp, and 1,347 cfm. It operates on 208-230/460V AC, 3-phase power with a single-speed, totally enclosed fan-cooled motor. The…

SKU 3G-OTH-80500

Brand
Dayton
Item
Panel Exhaust Fan: Direct Drive, 12 in Blade, 1/4 hp, 1,347 cfm, 208-230/460V AC
Category
Hazardous Location Direct-Drive Panel Exhaust Fans
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

Dayton
Type
1/4 hp, 1,347 cfm, 3 ph
AC
208-230/460V
Blade
12 in
Assembled
Assembled
Guard Type
None
Motor Type
3-Phase
Frame Finish
Zinc Plated
Frame Material
Steel
Motor Enclosure
Totally Enclosed Fan Cooled
Enclosure Design
Totally Enclosed Motor
Motor Insulation
Class B
Number of Speeds
1
Nameplate Voltage
208-230/460V AC
Guard Type Subheads
Without Intake Guards
Method of Construction
Stamped
Hazardous Location Class
Class I, Div 1, Group C and D

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Dayton Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The Dayton is a hazardous location direct-drive panel exhaust fan with a 12-inch blade, 1/4 hp, and 1,347 cfm. It operates on 208-230/460V AC, 3-phase power with a single-speed, totally enclosed fan-cooled motor. The unit is assembled with a zinc-plated steel frame and is rated for Class I, Div 1, Groups C and D, and Class II, Div 1, Groups F and G hazardous locations.

Frequently Asked Questions

What is the Dayton 3G-OTH-80500 panel exhaust fan used for?

The Dayton 3G-OTH-80500 is a hazardous location direct-drive panel exhaust fan designed for Class I, Div 1, Groups C and D, and Class II, Div 1, Groups F and G environments. It moves 1,347 cfm at 1/4 hp, making it suitable for ventilating industrial areas with flammable gases or combustible dusts.

What are the specifications of the Dayton 3G-OTH-80500?

The Dayton 3G-OTH-80500 has a 12-inch blade, 1/4 hp motor, 1,347 cfm airflow, and operates on 208-230/460V AC, 3-phase power. It features a zinc-plated steel frame, totally enclosed fan-cooled motor, Class B insulation, and single-speed operation. It is assembled and rated for hazardous locations.

Where to buy the Dayton 3G-OTH-80500 worldwide?

3G Electric supplies the Dayton 3G-OTH-80500 hazardous location exhaust fan to customers worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your site. Contact us for pricing and lead time on this direct-drive panel fan.

How to install a hazardous location panel exhaust fan?

Install the Dayton 3G-OTH-80500 in a panel cutout matching its 12-inch blade diameter, ensuring secure mounting to prevent vibration. Follow NEC and local codes for Class I, Div 1 wiring. Use proper conduit seals and verify the 208-230/460V AC, 3-phase supply matches nameplate. Always disconnect power before installation.

Used in

Common applications for Dayton
HVAC ventilation — DAYTON centrifugal upblast roof exhaust fans (SKU 7M7U3) for kitchen exhaust systems
Mechanical power transmission — DAYTON HTD timing pulleys (SKU 404GV0) for conveyor belt drives
Process water handling — DAYTON self-priming centrifugal pumps (SKU 2ZXT4) for dewatering or transfer
Roofing and building services — DAYTON fixed ventilated roof curbs (SKU 4HX59) for filtered supply fan installations
Material handling — DAYTON latch assemblies (SKU 2KEN4) for electric chain hoist hook safety
Industrial air movement — DAYTON downblast roof exhaust fans (SKU 3HFL9) for clean air exhaust in manufacturing plants

Dayton Products

3G Electric supplies Dayton hazardous location direct-drive panel exhaust fans. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Exhaust Fan: 24 in Blade, 3/4 hp, 7,102 cfm, 208-230/460V AC, 3 ph, Totally Enclosed
Dayton
Exhaust Fan: 24 in Blade, 3/4 hp, 7,102 cfm, 208-230/460V AC, 3 ph, Totally Enclosed
Exhaust Fan: 36 in Blade, 3/4 hp, 12,742 cfm, 208-230/460V AC, 3 ph, Totally Enclosed
Dayton
Exhaust Fan: 36 in Blade, 3/4 hp, 12,742 cfm, 208-230/460V AC, 3 ph, Totally Enclosed
Exhaust Fan: 20 in Blade, 1/2 hp, 4,452 cfm, 208-230/460V AC, 3 ph, Totally Enclosed
Dayton
Exhaust Fan: 20 in Blade, 1/2 hp, 4,452 cfm, 208-230/460V AC, 3 ph, Totally Enclosed
Exhaust Fan: Direct Drive, 20 in Blade, 1/2 hp, 4,495 cfm, 115/230V AC, 1 ph, Totally Enclosed
Dayton
Exhaust Fan: Direct Drive, 20 in Blade, 1/2 hp, 4,495 cfm, 115/230V AC, 1 ph, Totally Enclosed
Exhaust Fan: Direct Drive, 16 in Blade, 1/4 hp, 2,548 cfm, 115/230V AC, 1 ph, Totally Enclosed
Dayton
Exhaust Fan: Direct Drive, 16 in Blade, 1/4 hp, 2,548 cfm, 115/230V AC, 1 ph, Totally Enclosed
Exhaust Fan: Direct Drive, 16 in Blade, 1/20 hp, 1,334 cfm, 115V AC, 1 ph, Totally Enclosed
Dayton
Exhaust Fan: Direct Drive, 16 in Blade, 1/20 hp, 1,334 cfm, 115V AC, 1 ph, Totally Enclosed

More from Dayton

View all Dayton parts
Panel Exhaust Fan: Direct Drive, 16 in Blade, 1/4 hp, 2,476 cfm, 208-230/460V AC, 3 ph
Dayton
Panel Exhaust Fan: Direct Drive, 16 in Blade, 1/4 hp, 2,476 cfm, 208-230/460V AC, 3 ph