EXW Singapore — collect or forward from our Singapore office.

3G Electric
Dayton Flammable Vapor Belt-Drive Fan with Drive - Flammable Vapor Belt-Drive Fans with Drive
DaytonFlammable Vapor Belt-Drive Fans with Drive

Dayton Flammable Vapor Belt-Drive Fan with Drive

The DAYTON Tubeaxial Fan: Flammable Vapor (SKU 3G-OTH-77796) is a Class I Group C and D hazardous-location belt-drive fan with a Type B spark-resistant construction. This unassembled, horizontal-mount unit features a…

SKU 3G-OTH-77796

Brand
Dayton
Item
Flammable Vapor Belt-Drive Fan with Drive
Category
Flammable Vapor Belt-Drive Fans with Drive
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
EXW Singapore
Collect or forward from our office
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

Dayton
Type
5,730 cfm @ 0.000 in SP, 1/2 hp
AC
208-230/460V
Blade
24 in
Assembly
Unassembled
Motor Type
3-Phase
Motor Enclosure
Totally Enclosed Fan Cooled
Number of Speeds
1
Nameplate Voltage
208-230/460V AC
Mounting Orientation
Horizontal
Includes Drive Package
Yes
Airflow @ 0.000 in SP - Range
0 to 9,999 cfm
Hazardous Location Specification
Class I Group C
Spark Resistant Construction Type
B

Technical Documents

No technical documents available for this product.
Request documentation →
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Dayton Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The DAYTON Tubeaxial Fan: Flammable Vapor (SKU 3G-OTH-77796) is a Class I Group C and D hazardous-location belt-drive fan with a Type B spark-resistant construction. This unassembled, horizontal-mount unit features a 24-inch blade, a 3-phase totally enclosed fan-cooled motor, and a single-speed nameplate voltage of 208-230/460V AC. It delivers 5,730 cfm at 0.000 in SP with a 1/2 hp drive package included.

Frequently Asked Questions

What is the DAYTON Tubeaxial Fan used for?

The DAYTON Tubeaxial Fan is designed for hazardous locations where flammable vapors are present, such as chemical plants or refineries. Its Class I Group C and D rating and Type B spark-resistant construction make it suitable for ventilating areas with explosive atmospheres, ensuring safe air movement in industrial environments.

What are the specifications of the DAYTON Tubeaxial Fan ?

The DAYTON Tubeaxial Fan has a 24-inch blade, delivers 5,730 cfm at 0.000 in SP, and operates on 208-230/460V AC with a 1/2 hp motor. It features a 3-phase totally enclosed fan-cooled motor, horizontal mounting, and includes a drive package. The unit is unassembled and spark-resistant Type B.

Where to buy the DAYTON Tubeaxial Fan worldwide?

You can source the DAYTON Tubeaxial Fan through 3G Electric, a global industrial equipment distributor. We handle full logistics, customs clearance, and delivery to worldwide locations. Contact us for availability and lead time; we supply this fan to industrial buyers across multiple regions.

How to install the DAYTON Tubeaxial Fan ?

Install the DAYTON Tubeaxial Fan in a horizontal orientation, ensuring proper support for the unassembled drive package. Follow local electrical codes for 208-230/460V AC wiring and use certified conduit for hazardous locations. Verify spark-resistant construction integrity and secure all belt guards before operation.

Used in

Common applications for Dayton
Manufacturing — Dayton 21XJ72 motor for machine tool coolant pumps circulates coolant during cutting, grinding, and drilling operations.
Water management — Dayton 3YU59 submersible sump pump removes water from basements, crawl spaces, and construction sites.
HVAC — Dayton 804T11 unit heater provides supplemental heating in warehouses, workshops, and garages.
Power transmission — Dayton 2X897 pillow block bearing supports rotating shafts in conveyors, fans, and other machinery.
Workshop — Dayton 2LKR8 bench grinder sharpens tools and deburrs metal parts with dust exhaust for a cleaner environment.
Fluid handling — Dayton 5RGV6 fountain pump circulates and aerates water in decorative ponds and fountains.
Not sure this is the right part? Photo-identify it→

Dayton Products

3G Electric supplies Dayton flammable vapor belt-drive fans with drive. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion →Pumps & Compressors →Spare Parts →All Products →

More from Dayton

View all Dayton parts →
This unassembled belt-drive fan is designed for use in hazardous locations where flammable vapors may be present. It features a 36-inch blade, delivers 12,520 cfm at 0.000 in static pressure, and operates on 208-230/460V AC, 3-phase power with a 1 hp motor. The unit includes a drive package, has Type B spark-resistant construction, and is rated Class I Group C for vertical mounting
Dayton
This unassembled belt-drive fan is designed for use in hazardous locations where flammable vapors may be present. It features a 36-inch blade, delivers 12,520 cfm at 0.000 in static pressure, and operates on 208-230/460V AC, 3-phase power with a 1 hp motor. The unit includes a drive package, has Type B spark-resistant construction, and is rated Class I Group C for vertical mounting
This unassembled belt-drive fan is designed for moving flammable vapors in hazardous locations. It features a 34-inch blade delivering 19,290 cfm at 0.000 in SP, powered by a 230/460V AC, 3-phase, single-speed motor with a totally enclosed fan-cooled enclosure. The fan includes a drive package and is intended for vertical mounting. It meets Class I Group C and D hazardous location specifications with Spark Resistant Construction Type B
Dayton
This unassembled belt-drive fan is designed for moving flammable vapors in hazardous locations. It features a 34-inch blade delivering 19,290 cfm at 0.000 in SP, powered by a 230/460V AC, 3-phase, single-speed motor with a totally enclosed fan-cooled enclosure. The fan includes a drive package and is intended for vertical mounting. It meets Class I Group C and D hazardous location specifications with Spark Resistant Construction Type B
This belt-drive fan is designed for roof-mounted exhaust in hazardous locations classified as Class I Groups C & D and Class II Groups E, F & G. It features an 18 1/2 in wheel, delivers 3,655 cfm, and includes a drive package. The unassembled unit has a square base and is powered by a standard-efficiency, totally enclosed fan cooled motor rated at 208-230/460V AC
Dayton
This belt-drive fan is designed for roof-mounted exhaust in hazardous locations classified as Class I Groups C & D and Class II Groups E, F & G. It features an 18 1/2 in wheel, delivers 3,655 cfm, and includes a drive package. The unassembled unit has a square base and is powered by a standard-efficiency, totally enclosed fan cooled motor rated at 208-230/460V AC
This unassembled belt-drive fan is designed for hazardous locations with flammable vapors. It features a 30-inch blade, delivers 10,955 cfm at 0.000 in SP, and is powered by a 3-phase, 208-230/460V AC totally enclosed fan-cooled motor. Type B spark-resistant construction and Class I Group C rating reduce ignition risk. Includes drive package; mounts vertically
Dayton
This unassembled belt-drive fan is designed for hazardous locations with flammable vapors. It features a 30-inch blade, delivers 10,955 cfm at 0.000 in SP, and is powered by a 3-phase, 208-230/460V AC totally enclosed fan-cooled motor. Type B spark-resistant construction and Class I Group C rating reduce ignition risk. Includes drive package; mounts vertically

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first