We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

Dayton Line Volt Mechanical Tstat: -30° to 90°F, Steel, Fixed, 3°F - Indoor Single-Stage Controls
DaytonIndoor Single-Stage Controls

Dayton Line Volt Mechanical Tstat: -30° to 90°F, Steel, Fixed, 3°F

The DAYTON Line Volt Mechanical Tstat (SKU 3G-OTH-68337) is an indoor single-stage control with a fixed 3°F differential and a temperature control range of -30° to 90°F. It features a SPST switch that closes on rise…

SKU 3G-OTH-68337

Brand
Dayton
Item
Line Volt Mechanical Tstat: -30° to 90°F, Steel, Fixed, 3°F
Category
Indoor Single-Stage Controls
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

Dayton
Type
Steel, Fixed, 3°F
AC Volt
120V/240V/277V
Voltage
120V/240V/277V AC
Differential Type
Fixed
Enclosure Material
Steel
Switch Type/Action
SPST, Close on Rise
Temperature Differential
3°F
Temperature Control Range
-30° to 90°F
Capillary Length/Bulb Diameter
5 ft Capillary, 5 in x 1/4 in Bulb

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Dayton Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The DAYTON Line Volt Mechanical Tstat (SKU 3G-OTH-68337) is an indoor single-stage control with a fixed 3°F differential and a temperature control range of -30° to 90°F. It features a SPST switch that closes on rise, operates at 120V/240V/277V AC, and includes a 5 ft capillary with a 5 in x 1/4 in bulb. The steel enclosure houses this fixed-differential thermostat for line-voltage applications.

Frequently Asked Questions

What is the DAYTON Line Volt Mechanical Tstat used for?

The DAYTON Line Volt Mechanical Tstat () is used for indoor single-stage temperature control in industrial or commercial HVAC systems. It directly switches line-voltage circuits (120V/240V/277V AC) to regulate heating or cooling equipment, such as unit heaters or rooftop units, within a -30° to 90°F range.

What are the specifications of the DAYTON thermostat?

The DAYTON thermostat features a SPST switch that closes on rise, a fixed 3°F differential, and a temperature control range of -30° to 90°F. It operates at 120V/240V/277V AC, includes a 5 ft capillary with a 5 in x 1/4 in bulb, and has a steel enclosure. It is a line-voltage mechanical thermostat for indoor use.

Where to buy the DAYTON thermostat worldwide?

The DAYTON thermostat is available to order through 3G Electric, a global industrial equipment distributor. We handle full logistics, customs clearance, and delivery to worldwide destinations. Contact 3G Electric for pricing and lead time on this line-voltage mechanical thermostat.

How to install the DAYTON line volt mechanical thermostat?

Install the DAYTON thermostat by mounting the steel enclosure to a wall or panel, ensuring the capillary bulb is positioned in the controlled airstream. Connect line-voltage wiring (120V/240V/277V AC) per the SPST close-on-rise switch action. Always follow local electrical codes and disconnect power before installation.

Used in

Common applications for Dayton
HVAC ventilation — DAYTON centrifugal upblast roof exhaust fans (SKU 7M7U3) for kitchen exhaust systems
Mechanical power transmission — DAYTON HTD timing pulleys (SKU 404GV0) for conveyor belt drives
Process water handling — DAYTON self-priming centrifugal pumps (SKU 2ZXT4) for dewatering or transfer
Roofing and building services — DAYTON fixed ventilated roof curbs (SKU 4HX59) for filtered supply fan installations
Material handling — DAYTON latch assemblies (SKU 2KEN4) for electric chain hoist hook safety
Industrial air movement — DAYTON downblast roof exhaust fans (SKU 3HFL9) for clean air exhaust in manufacturing plants

Dayton Products

3G Electric supplies Dayton indoor single-stage controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
DAYTON Line Volt Mechanical Tstat: Heat or Cool, Stainless Steel, 30° to 110°F, 3.5°F
Dayton
DAYTON Line Volt Mechanical Tstat: Heat or Cool, Stainless Steel, 30° to 110°F, 3.5°F
DAYTON Line Volt Mechanical Tstat: Heat or Cool, Stainless Steel, 30° to 110°F, 3.5°F
Dayton
DAYTON Line Volt Mechanical Tstat: Heat or Cool, Stainless Steel, 30° to 110°F, 3.5°F
DAYTON Line Volt Mechanical Tstat: -30° to 90°F, Steel, Adj, 3° to 12°F, 120V/240V/277V AC Volt
Dayton
DAYTON Line Volt Mechanical Tstat: -30° to 90°F, Steel, Adj, 3° to 12°F, 120V/240V/277V AC Volt
DAYTON Line Volt Mechanical Tstat: Cool Only, Steel, -10° to 100°F, 2°F, Bi-Metal, 120 to 277V AC
Dayton
DAYTON Line Volt Mechanical Tstat: Cool Only, Steel, -10° to 100°F, 2°F, Bi-Metal, 120 to 277V AC
DAYTON Line Volt Mechanical Tstat: Heat Only, Steel, -10° to 100°F, 6°F to 8°F, Bi-Metal
Dayton
DAYTON Line Volt Mechanical Tstat: Heat Only, Steel, -10° to 100°F, 6°F to 8°F, Bi-Metal

More from Dayton

View all Dayton parts
DAYTON Line Volt Mechanical Tstat: Heat or Cool, Steel, 30° to 110°F, 3.5°F, Hydraulic Air Coil
Dayton
DAYTON Line Volt Mechanical Tstat: Heat or Cool, Steel, 30° to 110°F, 3.5°F, Hydraulic Air Coil
DAYTON Line Volt Mechanical Tstat: -30° to 90°F, Steel, Fixed, 3°F, 120V/240V/277V AC Volt
Dayton
DAYTON Line Volt Mechanical Tstat: -30° to 90°F, Steel, Fixed, 3°F, 120V/240V/277V AC Volt
DAYTON Line Volt Mechanical Tstat: -30° to 90°F, Stainless Steel, Fixed, 3°F, 120V/240V/277V AC Volt
Dayton
DAYTON Line Volt Mechanical Tstat: -30° to 90°F, Stainless Steel, Fixed, 3°F, 120V/240V/277V AC Volt
DAYTON Line Volt Mechanical Tstat: Cool Only, Stainless Steel, 30° to 110°F, 3.5°F, 120 to 270V AC
Dayton
DAYTON Line Volt Mechanical Tstat: Cool Only, Stainless Steel, 30° to 110°F, 3.5°F, 120 to 270V AC
DAYTON Line Volt Mechanical Tstat: 0° to 120°F, Plastic, Fixed, 3°F, 120V/240V/277V AC Volt
Dayton
DAYTON Line Volt Mechanical Tstat: 0° to 120°F, Plastic, Fixed, 3°F, 120V/240V/277V AC Volt
DAYTON Line Volt Mechanical Tstat: -30° to 90°F, Stainless Steel, Fixed, 3°F, 120V/240V/277V AC Volt
Dayton
DAYTON Line Volt Mechanical Tstat: -30° to 90°F, Stainless Steel, Fixed, 3°F, 120V/240V/277V AC Volt
DAYTON Line Volt Mechanical Tstat: Heat or Cool, Steel, -10° to 100°F, 2°F, Bi-Metal, 120 to 277V AC
Dayton
DAYTON Line Volt Mechanical Tstat: Heat or Cool, Steel, -10° to 100°F, 2°F, Bi-Metal, 120 to 277V AC
DAYTON Line Volt Mechanical Tstat: Cool Only, Steel, 30° to 110°F, 3.5°F, Hydraulic Air Coil
Dayton
DAYTON Line Volt Mechanical Tstat: Cool Only, Steel, 30° to 110°F, 3.5°F, Hydraulic Air Coil