Dayton Hydronic Wall and Ceiling Unit Heater: Steam/Water - Suspended Vertical Hydronic Wall & Ceiling Unit Heaters
DaytonSuspended Vertical Hydronic Wall & Ceiling Unit Heaters

Dayton Hydronic Wall and Ceiling Unit Heater: Steam/Water

The DAYTON Hydronic Wall and Ceiling Unit Heater (SKU 3G-OTH-67165) is a suspended vertical hydronic wall and ceiling unit heater designed for water heating. It delivers an air flow of 6.140 cfm and has a 2 in…

SKU 3G-OTH-67165

Brand
Dayton
Item
Hydronic Wall and Ceiling Unit Heater: Steam/Water
Category
Suspended Vertical Hydronic Wall & Ceiling Unit Heaters
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
EXW Singapore
Collect or forward from our office
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

Dayton
Type
280,800 BtuH Output @ 200 F Water
Air Flow
6.140 cfm
Fan Guard Type
No Guard
Heating Method
Water
Overall Dimensions - H x W x D
17-5/8 in x 37-1/2 in x 37-1/2 in
Connection Size, Connection Type
2 in, Threaded Male NPT

Technical Documents

No technical documents available for this product.
Request documentation →
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Dayton Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The DAYTON Hydronic Wall and Ceiling Unit Heater (SKU 3G-OTH-67165) is a suspended vertical hydronic wall and ceiling unit heater designed for water heating. It delivers an air flow of 6.140 cfm and has a 2 in threaded male NPT connection. The unit measures 17-5/8 in x 37-1/2 in x 37-1/2 in and comes without a fan guard.

Frequently Asked Questions

What is the DAYTON hydronic wall and ceiling unit heater used for?

The DAYTON is a suspended vertical hydronic unit heater used for space heating in industrial and commercial facilities. It uses hot water to deliver 280,800 BtuH output at 200 °F water, with an air flow of 6.140 cfm, making it suitable for warehouses, factories, and large open areas.

What are the specifications of the DAYTON unit heater?

The DAYTON has a 280,800 BtuH output at 200 °F water, air flow of 6.140 cfm, and a 2 in threaded male NPT connection. It measures 17-5/8 in x 37-1/2 in x 37-1/2 in, uses water heating, and comes without a fan guard. It is a suspended vertical hydronic wall and ceiling unit heater.

Where to buy the DAYTON unit heater worldwide?

3G Electric supplies the DAYTON hydronic unit heater to customers worldwide. As a global industrial solutions provider, we handle logistics, customs clearance, and delivery to your site. Contact us for pricing and lead time on this water heating unit.

How to install a DAYTON hydronic unit heater?

Install the DAYTON as a suspended vertical unit on a wall or ceiling, ensuring proper support for its weight. Connect the 2 in threaded male NPT water supply and return lines. Provide adequate clearance for air flow and follow local codes for water heating systems. No fan guard is included.

Used in

Common applications for Dayton
Manufacturing — Dayton 21XJ72 motor for machine tool coolant pumps circulates coolant during cutting, grinding, and drilling operations.
Water management — Dayton 3YU59 submersible sump pump removes water from basements, crawl spaces, and construction sites.
HVAC — Dayton 804T11 unit heater provides supplemental heating in warehouses, workshops, and garages.
Power transmission — Dayton 2X897 pillow block bearing supports rotating shafts in conveyors, fans, and other machinery.
Workshop — Dayton 2LKR8 bench grinder sharpens tools and deburrs metal parts with dust exhaust for a cleaner environment.
Fluid handling — Dayton 5RGV6 fountain pump circulates and aerates water in decorative ponds and fountains.
Not sure this is the right part? Photo-identify it→

Dayton Products

3G Electric supplies Dayton suspended vertical hydronic wall & ceiling unit heaters. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion →Pumps & Compressors →Spare Parts →All Products →

More from Dayton

View all Dayton parts →
This suspended vertical unit heater delivers 368,100 BtuH output at 200°F water with an air flow of 8,020 cfm. It uses water as the heating method and features a 2-1/2 in threaded male NPT connection. The unit measures 17-1/4 in x 42 in x 42 in and is supplied without a fan guard. Typical applications include heating large commercial or industrial spaces such as warehouses, factories, and workshops
Dayton
This suspended vertical unit heater delivers 368,100 BtuH output at 200°F water with an air flow of 8,020 cfm. It uses water as the heating method and features a 2-1/2 in threaded male NPT connection. The unit measures 17-1/4 in x 42 in x 42 in and is supplied without a fan guard. Typical applications include heating large commercial or industrial spaces such as warehouses, factories, and workshops
DAYTON Hydronic Wall and Ceiling Unit Heater: Steam/Water, 83,700 BtuH Output @ 200 F Water
Dayton
DAYTON Hydronic Wall and Ceiling Unit Heater: Steam/Water, 83,700 BtuH Output @ 200 F Water
This suspended vertical unit heater delivers 118,600 BtuH output at 200°F water with 2,620 cfm airflow. It features a 2-inch threaded male NPT connection and measures 14-1/8 in x 29-1/2 in x 29-1/2 in. Designed for water heating, it is suitable for wall or ceiling mounting in commercial or industrial spaces such as warehouses, factories, and workshops
Dayton
This suspended vertical unit heater delivers 118,600 BtuH output at 200°F water with 2,620 cfm airflow. It features a 2-inch threaded male NPT connection and measures 14-1/8 in x 29-1/2 in x 29-1/2 in. Designed for water heating, it is suitable for wall or ceiling mounting in commercial or industrial spaces such as warehouses, factories, and workshops
This suspended vertical hydronic unit heater delivers 22,700 BtuH output at 200°F water with 595 cfm air flow. It features a 1-1/2 in threaded male NPT connection and measures 10-5/8 in x 18-1/4 in x 18-1/4 in. Designed for space heating in commercial and industrial buildings, it is suitable for mounting on walls or ceilings in areas such as warehouses and workshops
Dayton
This suspended vertical hydronic unit heater delivers 22,700 BtuH output at 200°F water with 595 cfm air flow. It features a 1-1/2 in threaded male NPT connection and measures 10-5/8 in x 18-1/4 in x 18-1/4 in. Designed for space heating in commercial and industrial buildings, it is suitable for mounting on walls or ceilings in areas such as warehouses and workshops