We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

Dayton Centrifugal Downblast Roof Exhaust Fan: Belt Drive, Includes Drive Pack - Clean Air Belt-Drive Fans with Drive
DaytonClean Air Belt-Drive Fans with Drive

Dayton Centrifugal Downblast Roof Exhaust Fan: Belt Drive, Includes Drive Pack

The Dayton Centrifugal Downblast Roof Exhaust Fan is a belt-drive clean air fan with drive package, model. It features an 11-inch wheel, delivers 1,296 cfm, and operates on 115/208-230V AC with a single-speed, open…

SKU 3G-OTH-81374

Brand
Dayton
Item
Centrifugal Downblast Roof Exhaust Fan: Belt Drive, Includes Drive Pack
Category
Clean Air Belt-Drive Fans with Drive
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

Dayton
Type
Includes Drive Pack, 1,296 cfm, 1
Wheel
11 in
Assembly
Unassembled
Base Shape
Square
Drive Package
Includes Drive Package
Motor Enclosure
Open Dripproof
Motor Efficiency
Standard-Efficiency Motors
Number of Speeds
1
Mounting Location
Roof
Nameplate Voltage
115/208-230V AC
High-Efficiency Motor
No
Exhaust Airflow @ 0.000 in SP - Range
0 to 1,999 cfm
Exhaust Airflow @ 0.500 in SP - Range
0 to 1,999 cfm
For High-Static Pressure Applications
No

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Dayton Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The Dayton Centrifugal Downblast Roof Exhaust Fan is a belt-drive clean air fan with drive package, model. It features an 11-inch wheel, delivers 1,296 cfm, and operates on 115/208-230V AC with a single-speed, open dripproof motor. This unassembled unit is designed for roof mounting and is not for high-static-pressure applications.

Frequently Asked Questions

What is the Dayton centrifugal downblast roof exhaust fan used for?

The Dayton is a belt-drive clean air exhaust fan designed for roof mounting. It moves up to 1,296 cfm of general ventilation air in commercial or industrial buildings, such as warehouses or factories, where moderate static pressure is present.

What are the specifications of the Dayton roof exhaust fan?

The Dayton has an 11-inch wheel, delivers 1,296 cfm, and operates on 115/208-230V AC with a single-speed open dripproof motor. It includes a drive package, is unassembled, and is not for high-static-pressure applications. The base shape is square.

Where to buy the Dayton exhaust fan worldwide?

3G Electric supplies the Dayton centrifugal downblast roof exhaust fan worldwide. As a global industrial equipment distributor, we handle full logistics, customs clearance, and delivery to your site. Contact us for availability and lead time.

How to install the Dayton belt-drive roof exhaust fan?

Install the unassembled Dayton by mounting the square base securely on a roof curb, connecting ductwork, and wiring the motor per the nameplate voltage (115/208-230V AC). Follow standard belt-drive fan alignment and tensioning practices. Consult a licensed electrician.

Used in

Common applications for Dayton
HVAC ventilation — DAYTON centrifugal upblast roof exhaust fans (SKU 7M7U3) for kitchen exhaust systems
Mechanical power transmission — DAYTON HTD timing pulleys (SKU 404GV0) for conveyor belt drives
Process water handling — DAYTON self-priming centrifugal pumps (SKU 2ZXT4) for dewatering or transfer
Roofing and building services — DAYTON fixed ventilated roof curbs (SKU 4HX59) for filtered supply fan installations
Material handling — DAYTON latch assemblies (SKU 2KEN4) for electric chain hoist hook safety
Industrial air movement — DAYTON downblast roof exhaust fans (SKU 3HFL9) for clean air exhaust in manufacturing plants

Dayton Products

3G Electric supplies Dayton clean air belt-drive fans with drive. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Centrifugal Downblast Roof Exhaust Fan: Belt Drive, Includes Drive Pack, 11 in Wheel, 1,062 cfm, 1
Dayton
Centrifugal Downblast Roof Exhaust Fan: Belt Drive, Includes Drive Pack, 11 in Wheel, 1,062 cfm, 1
Centrifugal Downblast Roof Exhaust Fan: Belt Drive, Includes Drive Pack, 11 in Wheel, 1,386 cfm, 1
Dayton
Centrifugal Downblast Roof Exhaust Fan: Belt Drive, Includes Drive Pack, 11 in Wheel, 1,386 cfm, 1
Centrifugal Downblast Roof Exhaust Fan: Belt Drive, Includes Drive Pack, 11 in Wheel, 1,526 cfm, 1
Dayton
Centrifugal Downblast Roof Exhaust Fan: Belt Drive, Includes Drive Pack, 11 in Wheel, 1,526 cfm, 1
Centrifugal Downblast Roof Exhaust Fan: Belt Drive, Includes Drive Pack, 14 3/4 in Wheel, 3,163 cfm
Dayton
Centrifugal Downblast Roof Exhaust Fan: Belt Drive, Includes Drive Pack, 14 3/4 in Wheel, 3,163 cfm
Centrifugal Downblast Roof Exhaust Fan: Belt Drive, Includes Drive Pack, 14 3/4 in Wheel, 1,994 cfm
Dayton
Centrifugal Downblast Roof Exhaust Fan: Belt Drive, Includes Drive Pack, 14 3/4 in Wheel, 1,994 cfm
This Dayton clean air belt-drive fan includes a drive package and is designed for roof-mounted exhaust ventilation. It features a 13 1/4 in wheel, delivers 1,880 cfm, and operates on 115/208-230V AC with an open dripproof motor. The unassembled unit has a square base and is suited for general exhaust applications where high static pressure is not required
Dayton
This Dayton clean air belt-drive fan includes a drive package and is designed for roof-mounted exhaust ventilation. It features a 13 1/4 in wheel, delivers 1,880 cfm, and operates on 115/208-230V AC with an open dripproof motor. The unassembled unit has a square base and is suited for general exhaust applications where high static pressure is not required

More from Dayton

View all Dayton parts
Centrifugal downblast roof exhaust fan for clean air applications. Belt-driven with included drive package. Unassembled unit with square base, 14 3/4 in wheel, delivers 2,866 cfm. Single-speed open dripproof motor, 208-230/460V AC. Suitable for general ventilation exhausting stale air, fumes, or heat from commercial or industrial buildings
Dayton
Centrifugal downblast roof exhaust fan for clean air applications. Belt-driven with included drive package. Unassembled unit with square base, 14 3/4 in wheel, delivers 2,866 cfm. Single-speed open dripproof motor, 208-230/460V AC. Suitable for general ventilation exhausting stale air, fumes, or heat from commercial or industrial buildings
Belt-drive axial downblast roof exhaust fan for industrial and commercial clean-air applications. Includes drive package, open dripproof standard-efficiency motor, single speed, 208-230/460V AC. Unassembled unit with square base, 30-inch blade, delivers 5073 cfm exhaust airflow
Dayton
Belt-drive axial downblast roof exhaust fan for industrial and commercial clean-air applications. Includes drive package, open dripproof standard-efficiency motor, single speed, 208-230/460V AC. Unassembled unit with square base, 30-inch blade, delivers 5073 cfm exhaust airflow
Unassembled belt-drive fan with a 21-inch blade and spark-resistant construction type B. Delivers 4,042 cfm at 0.000 in static pressure. Powered by a 3-phase, totally enclosed fan-cooled motor rated 208-230/460V AC, single speed. Includes drive package for horizontal mounting. Suitable for general clean-air ventilation in industrial facilities
Dayton
Unassembled belt-drive fan with a 21-inch blade and spark-resistant construction type B. Delivers 4,042 cfm at 0.000 in static pressure. Powered by a 3-phase, totally enclosed fan-cooled motor rated 208-230/460V AC, single speed. Includes drive package for horizontal mounting. Suitable for general clean-air ventilation in industrial facilities
Belt-drive centrifugal downblast roof exhaust fan for general ventilation in commercial or industrial buildings. Includes drive package, open dripproof standard-efficiency motor, 115/208-230V AC single-speed. Delivers 3,692 cfm at low static pressures; unassembled square base. Not for high-static-pressure applications
Dayton
Belt-drive centrifugal downblast roof exhaust fan for general ventilation in commercial or industrial buildings. Includes drive package, open dripproof standard-efficiency motor, 115/208-230V AC single-speed. Delivers 3,692 cfm at low static pressures; unassembled square base. Not for high-static-pressure applications
Unassembled belt-drive fan with a 21-inch blade delivering 5,407 cfm at 0.000 in SP. Features a 1-speed capacitor-start motor with totally enclosed fan-cooled enclosure, rated for 115/208-230V AC, 1-phase. Includes drive package. Spark Resistant Construction Type B. Suitable for general clean-air ventilation and air movement in industrial facilities
Dayton
Unassembled belt-drive fan with a 21-inch blade delivering 5,407 cfm at 0.000 in SP. Features a 1-speed capacitor-start motor with totally enclosed fan-cooled enclosure, rated for 115/208-230V AC, 1-phase. Includes drive package. Spark Resistant Construction Type B. Suitable for general clean-air ventilation and air movement in industrial facilities
Belt-drive centrifugal downblast roof exhaust fan for clean air applications. Includes drive package; unassembled with square base. Wheel diameter 30 1/2 in, airflow 12,311 cfm. Single-speed open dripproof motor, 208-230/460V AC. Suitable for general ventilation exhausting large air volumes through roof openings
Dayton
Belt-drive centrifugal downblast roof exhaust fan for clean air applications. Includes drive package; unassembled with square base. Wheel diameter 30 1/2 in, airflow 12,311 cfm. Single-speed open dripproof motor, 208-230/460V AC. Suitable for general ventilation exhausting large air volumes through roof openings
This unassembled belt-drive fan features a 24-inch blade and delivers 7,925 cfm at 0.000 in static pressure. It is powered by a 3-phase, 208-230/460V AC motor with a totally enclosed fan-cooled enclosure and single-speed operation. The fan includes a drive package and is designed for horizontal mounting. Type B spark-resistant construction makes it suitable for general clean-air ventilation in industrial settings where spark resistance is required
Dayton
This unassembled belt-drive fan features a 24-inch blade and delivers 7,925 cfm at 0.000 in static pressure. It is powered by a 3-phase, 208-230/460V AC motor with a totally enclosed fan-cooled enclosure and single-speed operation. The fan includes a drive package and is designed for horizontal mounting. Type B spark-resistant construction makes it suitable for general clean-air ventilation in industrial settings where spark resistance is required
Unassembled belt-drive fan with a 16-inch blade delivering 2,379 cfm at 0.000 in static pressure. Features a 3-phase, totally enclosed fan-cooled motor rated at 208-230/460V AC with one speed. Includes drive package and is designed for vertical mounting. Spark Resistant Construction Type B suitable for clean-air ventilation in industrial environments where reduced ignition risk is required
Dayton
Unassembled belt-drive fan with a 16-inch blade delivering 2,379 cfm at 0.000 in static pressure. Features a 3-phase, totally enclosed fan-cooled motor rated at 208-230/460V AC with one speed. Includes drive package and is designed for vertical mounting. Spark Resistant Construction Type B suitable for clean-air ventilation in industrial environments where reduced ignition risk is required