The Danfoss iC2-Micro is a compact general purpose drive (MPN 132L6105) with a Black/Blue/Gray finish. It features single-phase input and three-phase output at 200-240V AC, rated for 1 1/2 hp with an IP20 enclosure…

SKU 3G-OTH-56641

Brand
Danfoss
Item
Compact General Purpose Drive: In Phase Single, Out Phase Three, 1 1/2 hp
Category
Danfoss iC2-Micro
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

Danfoss
Manufacturer Part Number
132L6105
Type
Out Phase Three, 1 1/2 hp, IP20, No Bypass
Color
Black/Blue/Gray
Style
Compact
Output Phase
Three
Output Voltage
200-240V AC

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Danfoss Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The Danfoss iC2-Micro is a compact general purpose drive (MPN 132L6105) with a Black/Blue/Gray finish. It features single-phase input and three-phase output at 200-240V AC, rated for 1 1/2 hp with an IP20 enclosure and no bypass.

Frequently Asked Questions

What is the Danfoss iC2-Micro compact drive used for?

The Danfoss iC2-Micro compact general purpose drive is used for variable-speed control of three-phase motors in applications such as conveyors, pumps, fans, and compressors. Its single-phase input and three-phase output at 200-240V AC make it suitable for light industrial and commercial equipment requiring precise motor speed regulation.

What are the specifications of the Danfoss iC2-Micro MPN 132L6105?

The Danfoss iC2-Micro MPN 132L6105 is a compact drive with single-phase input and three-phase output at 200-240V AC, rated for 1 1/2 hp. It has an IP20 enclosure, no bypass, and a Black/Blue/Gray finish. This Danfoss model is designed for general purpose motor control in space-constrained installations.

Where to buy the Danfoss iC2-Micro drive worldwide?

You can source the Danfoss iC2-Micro drive (MPN 132L6105) worldwide through 3G Electric, a global industrial equipment distributor. We handle full logistics, customs clearance, and delivery to your location. Contact us for availability and lead time; we provide reliable sourcing for this Danfoss compact drive.

How to install the Danfoss iC2-Micro compact drive?

Install the Danfoss iC2-Micro drive on a flat, vertical surface in a clean, dry area with adequate ventilation. Follow the manual for wiring single-phase input and three-phase output at 200-240V AC. Ensure the IP20 enclosure is protected from dust and moisture. Use proper fusing and grounding per local codes.

Used in

Common applications for Danfoss
Light-oil industrial burners — OD / OD-H nozzles as scheduled replacement parts
Heating-boiler oil-supply circuits — BFP 10L / 11L / 41L pumps and coupling kits
Burner-rack solenoid valves — EV and EVR series for oil and gas shut-off
Legacy plant troubleshooting — matching a failed burner nameplate to correct Danfoss nozzle/pump combination
Refrigeration pressure controls — KP / RT series for secondary-refrigerant loops

Danfoss Products

3G Electric supplies Danfoss danfoss ic2-micro. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
FUJI ELECTRIC Variable Frequency Drive: In Phase Three, Out Phase Three, 7 1/2 hp, No Bypass, Blue (MPN FRN0013C2S-4U)
FUJI ELECTRIC
FUJI ELECTRIC Variable Frequency Drive: In Phase Three, Out Phase Three, 7 1/2 hp, No Bypass, Blue (MPN FRN0013C2S-4U)
FUJI ELECTRIC Variable Frequency Drive: In Phase Three, Out Phase Three, 10 hp, No Bypass, Heat Sink (MPN FRN0018C2S-4U)
FUJI ELECTRIC
FUJI ELECTRIC Variable Frequency Drive: In Phase Three, Out Phase Three, 10 hp, No Bypass, Heat Sink (MPN FRN0018C2S-4U)
FUJI ELECTRIC Variable Frequency Drive: In Phase Three, Out Phase Three, 2 hp, No Bypass, Heat Sink (MPN FRN0010C2S-2U)
FUJI ELECTRIC
FUJI ELECTRIC Variable Frequency Drive: In Phase Three, Out Phase Three, 2 hp, No Bypass, Heat Sink (MPN FRN0010C2S-2U)
FUJI ELECTRIC Variable Frequency Drive: In Phase Three, Out Phase Three, 40 hp, IP20, No Bypass (MPN FRN0115G2S-2GU)
FUJI ELECTRIC
FUJI ELECTRIC Variable Frequency Drive: In Phase Three, Out Phase Three, 40 hp, IP20, No Bypass (MPN FRN0115G2S-2GU)
FUJI ELECTRIC Variable Frequency Drive: In Phase Single/Three, Out Phase Three, 5 hp, No Bypass (MPN FRN0009G2S-4GU)
FUJI ELECTRIC
FUJI ELECTRIC Variable Frequency Drive: In Phase Single/Three, Out Phase Three, 5 hp, No Bypass (MPN FRN0009G2S-4GU)
FUJI ELECTRIC Variable Frequency Drive: In Phase Three, Out Phase Three, 5 hp, No Bypass, Heat Sink (MPN FRN0007E2S-4GB)
FUJI ELECTRIC
FUJI ELECTRIC Variable Frequency Drive: In Phase Three, Out Phase Three, 5 hp, No Bypass, Heat Sink (MPN FRN0007E2S-4GB)

More from Danfoss

View all Danfoss parts
DANFOSS Compact General Purpose Drive Assembly: In Phase Three, Out Phase Three, 1/2 hp, No Bypass (MPN 132L6116 + 132G0190)
Danfoss
DANFOSS Compact General Purpose Drive Assembly: In Phase Three, Out Phase Three, 1/2 hp, No Bypass (MPN 132L6116 + 132G0190)
DANFOSS Compact General Purpose Drive: In Phase Three, Out Phase Three, 2 hp, IP20, No Bypass, Black (MPN 137H7365)
Danfoss
DANFOSS Compact General Purpose Drive: In Phase Three, Out Phase Three, 2 hp, IP20, No Bypass, Black (MPN 137H7365)
DANFOSS Compact General Purpose Drive Assembly: In Phase Single, Out Phase Three, 1/2 hp, No Bypass (MPN 132L5989 + 132G0188)
Danfoss
DANFOSS Compact General Purpose Drive Assembly: In Phase Single, Out Phase Three, 1/2 hp, No Bypass (MPN 132L5989 + 132G0188)
DANFOSS Compact General Purpose Drive Assembly: In Phase Three, Out Phase Three, 2 hp, No Bypass (MPN 137H7365 + 132G0191)
Danfoss
DANFOSS Compact General Purpose Drive Assembly: In Phase Three, Out Phase Three, 2 hp, No Bypass (MPN 137H7365 + 132G0191)
DANFOSS Compact General Purpose Drive Assembly: In Phase Three, Out Phase Three, 5 hp, No Bypass (MPN 132L6121 + 132G0191)
Danfoss
DANFOSS Compact General Purpose Drive Assembly: In Phase Three, Out Phase Three, 5 hp, No Bypass (MPN 132L6121 + 132G0191)
DANFOSS Compact General Purpose Drive Assembly: In Phase Three, Out Phase Three, 1/2 hp, No Bypass (MPN 137H9252 + 132G0190)
Danfoss
DANFOSS Compact General Purpose Drive Assembly: In Phase Three, Out Phase Three, 1/2 hp, No Bypass (MPN 137H9252 + 132G0190)
DANFOSS Compact General Purpose Drive Assembly: In Phase Three, Out Phase Three, 2 hp, No Bypass (MPN 132L6118 + 132G0190)
Danfoss
DANFOSS Compact General Purpose Drive Assembly: In Phase Three, Out Phase Three, 2 hp, No Bypass (MPN 132L6118 + 132G0190)
DANFOSS Compact General Purpose Drive Assembly: In Phase Three, Out Phase Three, 4 hp, No Bypass (MPN 132L6120 + 132G0191)
Danfoss