We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

COLE-PARMER Hydrometer: Specific Gravity Plain Form, 1.000/1.220, 0.002, Ballast - Specific Gravity (Baume) Hydrometers
COLE-PARMERSpecific Gravity (Baume) Hydrometers

COLE-PARMER Hydrometer: Specific Gravity Plain Form, 1.000/1.220, 0.002, Ballast

The COLE-PARMER Specific Gravity Plain Form Hydrometer (SKU 0829884, MPN 0829884) measures specific gravity over a range of 1.000/1.220 with scale divisions of 0.002 and an accuracy of +/-0.002°. This ballast-type…

SKU 3G-OTH-638552

Brand
COLE-PARMER
Item
Hydrometer: Specific Gravity Plain Form, 1.000/1.220, 0.002, Ballast
Category
Specific Gravity (Baume) Hydrometers
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

COLE-PARMER
Manufacturer Part Number
0829884
Type
1.000/1.220, 0.002, Ballast, +/-0.002°
Range
1.000/1.220
Scale Type
Specific Gravity Plain Form
Scale Divisions
0.002

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

COLE-PARMER Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The COLE-PARMER Specific Gravity Plain Form Hydrometer (SKU 0829884, MPN 0829884) measures specific gravity over a range of 1.000/1.220 with scale divisions of 0.002 and an accuracy of +/-0.002°. This ballast-type instrument is designed for direct reading of specific gravity in liquid samples.

Frequently Asked Questions

What is the COLE-PARMER Specific Gravity Plain Form Hydrometer used for?

This hydrometer measures specific gravity of liquids in industrial processes such as chemical mixing, wastewater treatment, and quality control. It provides direct readings over a 1.000/1.220 range with 0.002 scale divisions, suitable for field or lab use.

What are the specifications of the COLE-PARMER 0829884 hydrometer?

The COLE-PARMER 0829884 hydrometer has a specific gravity range of 1.000/1.220, scale divisions of 0.002, and accuracy of +/-0.002°. It is a ballast-type plain form instrument, MPN 0829884, designed for direct reading in liquid samples.

Where to buy COLE-PARMER hydrometer 0829884 worldwide?

3G Electric supplies the COLE-PARMER 0829884 hydrometer worldwide. We handle full logistics and customs clearance to deliver this specific gravity instrument to your facility. Contact us for availability and lead time on this precision measurement tool.

How to use a COLE-PARMER specific gravity hydrometer correctly?

Ensure the liquid sample is clean and at a stable temperature. Gently lower the hydrometer into the liquid, spin it to release air bubbles, and read the scale at the liquid meniscus. Avoid touching the stem during reading for accurate +/-0.002° measurement.

Used in

Common applications for COLE-PARMER
Laboratory sample preparation — Cole-Parmer serological pipettes (10 mL, sterile) for precise liquid transfer in cell culture workflows.
Moisture content analysis — Cole-Parmer moisture balance (50 g capacity, 0.0001 g readability) for quality control in food and pharmaceutical powders.
Cryogenic storage — Cole-Parmer cryogenic dewar (35 L, aluminum) for long-term preservation of biological samples in liquid nitrogen.
Manual pipetting in research labs — Cole-Parmer single-channel pipettors (fixed volume, autoclavable) for repetitive dispensing of reagents.
Industrial fluidized sand bath operation — Cole-Parmer basket and lid accessories for maintaining temperature uniformity in material testing.
Electrophoresis staining — Cole-Parmer Green Prestain for protein or nucleic acid visualization in gel electrophoresis.

COLE-PARMER Products

3G Electric supplies COLE-PARMER specific gravity (baume) hydrometers. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

More from COLE-PARMER

View all COLE-PARMER parts
Hydrometer: Specific Gravity Plain Form, 1.180/1.250, 0.0005, Ballast, +/-0.001° (MPN 0829871)
COLE-PARMER
Hydrometer: Specific Gravity Plain Form, 1.180/1.250, 0.0005, Ballast, +/-0.001° (MPN 0829871)
Hydrometer: Specific Gravity Plain Form, 1.240/1.310, 0.0005, Ballast, +/-0.001° (MPN 0829873)
COLE-PARMER
Hydrometer: Specific Gravity Plain Form, 1.240/1.310, 0.0005, Ballast, +/-0.001° (MPN 0829873)
Hydrometer: Specific Gravity Plain Form, 1.000/1.050, 0.001, Ballast, +/-0.001° (MPN 0829780)
COLE-PARMER
Hydrometer: Specific Gravity Plain Form, 1.000/1.050, 0.001, Ballast, +/-0.001° (MPN 0829780)
Hydrometer: Baume Plain Form, 29/41°, 0.1, Ballast, +/-0.1°, 11 3/4 in Overall Ht (MPN 0829949)
COLE-PARMER
Hydrometer: Baume Plain Form, 29/41°, 0.1, Ballast, +/-0.1°, 11 3/4 in Overall Ht (MPN 0829949)
Hydrometer: Baume Plain Form, 0/50, 1, Ballast, +/-1.0°, 11 3/4 in Overall Ht (MPN 0829961)
COLE-PARMER
Hydrometer: Baume Plain Form, 0/50, 1, Ballast, +/-1.0°, 11 3/4 in Overall Ht (MPN 0829961)
Specific Gravity Hydrometer: Specific Gravity Combined Form, 1.000/1.220, 0.002, Ballast, +/-0.002° (MPN 0829763)
COLE-PARMER
Specific Gravity Hydrometer: Specific Gravity Combined Form, 1.000/1.220, 0.002, Ballast, +/-0.002° (MPN 0829763)
Hydrometer: Soil Specific Gravity Plain Form, 5/60 g/L, 1.0 g/L, Ballast, +/-1 g/L, 11 in Overall Ht (MPN 0829742)
COLE-PARMER
Hydrometer: Soil Specific Gravity Plain Form, 5/60 g/L, 1.0 g/L, Ballast, +/-1 g/L, 11 in Overall Ht (MPN 0829742)
Hydrometer: Specific Gravity Plain Form, 1.000/1.600, 0.005, Ballast, +/-0.005° (MPN 0829880)
COLE-PARMER
Hydrometer: Specific Gravity Plain Form, 1.000/1.600, 0.005, Ballast, +/-0.005° (MPN 0829880)