We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

3G Electric
CLEVELAND CONTROLS AFS-304 Adjustable Set-Point Air Pressure Switch - Adjustable Set-Point Air Pressure Switches
CLEVELAND CONTROLSAdjustable Set-Point Air Pressure Switches

CLEVELAND CONTROLS AFS-304 Adjustable Set-Point Air Pressure Switch

The CLEVELAND CONTROLS AFS-304 is an adjustable set-point air pressure switch with auto reset, SPDT switching, and a switch voltage of 277V AC. It has an adjustable range of 0.05 in wc to 2 in wc and is open mounted.

SKU 3G-OTH-69609

Also listed as: AFS304 · AFS 304

Brand
CLEVELAND CONTROLS
Item
AFS-304 Adjustable Set-Point Air Pressure Switch
Part Number
AFS-304
Category
Adjustable Set-Point Air Pressure Switches
Available to Order
Also known as:AFS-304CLEVELAND CONTROLS
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

CLEVELAND CONTROLS
Manufacturer Part Number
AFS-304
Type
Auto Reset, 0.05 in wc to 2 in wc, Open Mounted, SPDT
AC
277V
Switch Voltage
277V AC

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

CLEVELAND CONTROLS Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The CLEVELAND CONTROLS AFS-304 is an adjustable set-point air pressure switch with auto reset, SPDT switching, and a switch voltage of 277V AC. It has an adjustable range of 0.05 in wc to 2 in wc and is open mounted.

Frequently Asked Questions

What is the CLEVELAND CONTROLS AFS-304 air pressure switch used for?

The CLEVELAND CONTROLS AFS-304 is used to monitor and control air pressure in HVAC, ventilation, and industrial air-handling systems. It actuates an SPDT switch when pressure reaches the adjustable set point, enabling automated fan, damper, or filter-status control.

What are the specifications of the CLEVELAND CONTROLS AFS-304?

The AFS-304 is an adjustable set-point air pressure switch with auto reset, SPDT switching, and a switch voltage of 277V AC. Its adjustable range is 0.05 in wc to 2 in wc, and it is open mounted. The manufacturer part number is AFS-304.

Where to buy the CLEVELAND CONTROLS AFS-304 worldwide?

3G Electric supplies the CLEVELAND CONTROLS AFS-304 worldwide. As a global industrial equipment distributor, we handle full logistics, customs clearance, and delivery to your site. Contact us for availability and lead time.

How to install the CLEVELAND CONTROLS AFS-304 air pressure switch?

Mount the AFS-304 in a clean, dry location with the pressure port connected to the sensed air duct. Wire the SPDT contacts per your control circuit (max 277V AC). Adjust the set point using the screw mechanism. Always follow local electrical codes and the manufacturer's manual.

Used in

Common applications for CLEVELAND CONTROLS
HVAC duct airflow monitoring — Cleveland Controls static pressure probe with 1/2 in smooth connection and 4 in insertion length (MPN 21117) for measuring static pressure in supply or return ducts.
Filter differential pressure monitoring — Cleveland Controls static pressure probe with 1 in barb connection and 3 1/2 in insertion length (MPN 21398-112) used to sense pressure drop across filters.
Clean room pressure control — Cleveland Controls static pressure probe with 1/2 in barb connection and 8 in insertion length (MPN 21119-112) for low-pressure measurement in controlled environments.
Combustion air proving — Cleveland Controls static pressure probe with 1 in smooth connection and 1 1/2 in insertion length (MPN 21397) to verify airflow in burner systems.
Ventilation system balancing — Cleveland Controls static pressure probe with 1/2 in smooth connection and 6 in insertion length (MPN 21118) for measuring pressure in large ducts.
Industrial exhaust monitoring — Cleveland Controls static pressure probe with 1 in barb connection and 2 in insertion length (MPN 21116-112) for pressure sensing in exhaust stacks.
Not sure this is the right part? Photo-identify it

CLEVELAND CONTROLS Products

3G Electric supplies CLEVELAND CONTROLS adjustable set-point air pressure switches. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

More from CLEVELAND CONTROLS

View all CLEVELAND CONTROLS parts
Auto-reset SPDT switch with adjustable set-point range of 0.05 in wc to 2 in wc. Rated 277V AC. Open mounted. Used for sensing low air pressure differentials in HVAC, combustion, and industrial ventilation systems for alarm, interlock, or control functions
CLEVELAND CONTROLS
Auto-reset SPDT switch with adjustable set-point range of 0.05 in wc to 2 in wc. Rated 277V AC. Open mounted. Used for sensing low air pressure differentials in HVAC, combustion, and industrial ventilation systems for alarm, interlock, or control functions
Auto reset adjustable set-point air pressure switch with a range of 0.05 in wc to 12 in wc. Features SPDT contacts rated at 277V AC, housed in a conduit box with barb connection. Used for monitoring air pressure in HVAC systems, such as duct static pressure, filter status, and fan proving
CLEVELAND CONTROLS
Auto reset adjustable set-point air pressure switch with a range of 0.05 in wc to 12 in wc. Features SPDT contacts rated at 277V AC, housed in a conduit box with barb connection. Used for monitoring air pressure in HVAC systems, such as duct static pressure, filter status, and fan proving

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first