IGNITION DESCRIPTION
TRANSFORMERS Ignition transformers series T11 and T16 are suitable for
fluid or gaseous fuel burners.
Ignition transformers series T13 and T17, with 100% duty-
cycle, are particularly suitable for the application on
industrial machines (e.g. water cleaners).
Type T11 and T13
FEATURES
Followings are the main features of this series:
- various connection and fixing systems;
- high discharge power (they are particularly suitable in all
those applications in which long ignition wires are
required);
- high efficiency and ignition power.
TECHNICAL DATA
- Supply voltage: 220V - 50Hz
(different voltage and frequency values are available on
request)
- Operating temperature range: -10°C +60°C
- Isolation: polyester resin
- Recommended distance between
Type T16 and T17
the electrodes: 3 ÷ 5 mm
- Supply cable standard length: 550 mm
T11/... T13/… T16/... T17/...
Number of poles 1 1 2 2
Output peak
1x9 1x8 2x5 2x4
voltage (KV)
Output effective
20 16 20 16
current (mA) (1)
Input effective
1,1 0,65 1,1 0,7
current (A)
33% in 3 33% in 3
Duty cycle 100% 100%
minutes minutes
Power
240 145 240 155
consumption (VA)
Weight (Kg) 2 2 2 2
(1) : short circuit secondary.
CONSTRUCTION
The magnetic circuit across the transformer is mantle-
shaped (see general features in Figure 1 and Figure 2).
The secondary windings are center grounded.
The transformer is provided with a radio interference
suppression shield, which for its effectiveness must be
connected to a good ground.
Two fire painted caps cover the coils and form a whole with
the magnetic circuit.
Each transformer is detected by the fixed letter T
(transformer), by a series of numbers that indicate the
model and possibly by a letter of the alphabet which
determines a particular fixing system:
29087_r00 1/3
CONNECTION
T XX / X
The high voltage isolators employed in this series of
→ fixing system transformers are of two different types, according as the
→ model connection with high voltage cables occurs by means of a
screw, 4 mm diameter cylindrical terminal or of a 6.3 mm
diameter cylindrical terminal.
If the fixing system used is standard, the corresponding If not expressly mentioned, the connection terminal used is
reference letter is not inserted in the part reference. a screw terminal. The insulators are made of PBT.
For instance, the part reference T11 refers to a transformer
with standard fixing system, whereas the part reference T11/B
corresponds to a T11 transformer with different fixing system INSTALLATION
(see table 1, type B).
- Connect and disconnect the ignition transformer only after
The transformers of this series can have the same electric
switching off the power supply.
features but different fixing systems, or vice versa.
- Respect the applicable national and European standards
(e.g. EN 60355-1 / EN 50165) regarding electrical safety.
OVERALL DIMENSIONS - Make sure that the earth of the transformer and the earth of
the electric system are well connected.
Figures 1 and 2 show the main overall dimensions and Table
1 the various transformers fixing systems. - The device can be mounted in any position.
- Do not put high voltage cables next to other cables.
- Guarantee a protection degree suitable to the application.
T11/… - T13/…
primary coil
Noise shield
Magnetic shunt secondary coil
Alimentation cable magnetic circuit
Figure 1
T16/… - T17/…
primary coil
Noise shield
secondary coil
Magnetic shunt
Alimentation cable magnetic circuit
Figure 2
2/3 29087_r00
FIXING SYSTEMS
T…/B
T…/N T…/NC
T…/M T…/MC T…/F - T…/C
T…/R T…/RC
T…/W T…/AN
Table 1
Note : The images are representative and should therefore be considered only for fixing purpose.
NOTES ABOUT PRODUCT DISPOSAL
The device contains electronic components and cannot therefore be disposed of as normal household waste.
For the disposal procedure, please refer to the local rules in force for special waste.
ATTENTION -> Brahma S.p.A. accepts no responsibility for any damage resulting from customer tampering with the product.