Satronic Cell FC 8/R - Burner Controls
SatronicBurner Controls

Satronic Cell FC 8/R

The Satronic Cell FC 8/R is a burner control unit designed for industrial flame detection and burner management. It features frontal flame sensor sensitivity ranging from 1.5–5.5 lux depending on configuration, an…

SKU 3G-CBM-05979

Also listed as: REL 40202 · REL-40202

Brand
Satronic
Item
Cell FC 8/R
Category
Burner Controls
UNSPSC
40101833 — Boiler or heater igniter
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

Satronic
fc13 width
43 mm
fc14 width
43.5 mm
fc13 height
66.7 mm
fc14 height
61 mm
fc14l width
100 mm
fc14l height
117.5 mm
flame sensor life
approximately 50,000 hours
fc13 inner diameter
∅8.5 mm
fc13 outer diameter
∅17.5 mm
fc14 inner diameter
∅8.5 mm
fc14 outer diameter
∅17.5 mm
fc14l inner diameter
∅8.5 mm
fc14l outer diameter
∅17.5 mm
fc7 a lateral sensitivity
1.5–3.0 lux
fc7 r lateral sensitivity
1.5–5.5 lux
fc7 v lateral sensitivity
3.0–5.5 lux
fc8 a frontal sensitivity
1.5–3.0 lux
fc8 r frontal sensitivity
1.5–5.5 lux
fc8 v frontal sensitivity
3.0–5.5 lux
fc9 a lateral sensitivity
1.5–3.0 lux
fc9 n lateral sensitivity
1.5–5.5 lux
fc9 v lateral sensitivity
3.0–5.5 lux
fc11 drilling plane spacing
17 mm
operating temperature range
0°C to +60°C
fc11 drilling plane diameter
∅8.5 mm
standard connecting cable length
600 mm
fc11 a frontal lateral sensitivity
1.5–3.0 lux
fc11 n frontal lateral sensitivity
1.5–6.5 lux
fc13 a frontal lateral sensitivity
1.5–3.0 lux
fc13 r frontal lateral sensitivity
1.5–6.5 lux
fc14 a frontal lateral sensitivity
1.5–3.0 lux
fc14 r frontal lateral sensitivity
1.5–6.5 lux
fc14l a frontal lateral sensitivity
1.5–3.0 lux
fc14l r frontal lateral sensitivity
1.5–6.5 lux

Datasheet Content

PHOTOCELLS FLAME SENSORS FOR FUEL OIL BURNERS FC7 Introduction Flame detection in fuel oil burners occurs by means of sensors detecting the presence of flame through an electrical FC8 signal, which can be used by ignition and control devices. Generally, to detect the presence of flame in these appliances a photocell is used, which exploits the light generated by the flame itself. Description These are the most used flame sensors for fuel oil burners. Photocells vary their ohmic resistance according to the light FC9 incidence; this property is exploited to detect the occurred flame generation in burners. Various types of photocells are available, differing from each other in their application and casing. Fig.1 shows the FC7, FC8 and FC9 photocells; the difference between FC7 and FC8 models consists in the detecting element, which lights up laterally in the FC7 and frontally in the FC8. The FC9 photocell is suitable to be light up laterally; an inbuilt diode FC11 enables this photocell to be used with particular devices (for example Brahma 32CN ). Fig.2 shows the FC11, FC13 and FC14 photocells, differing from each other only in the fixing system, as both of them light up laterally and frontally. Fig.3 shows FC14 and FC14L photocells, differing from each other in the case length, even if both of them are able to be light up laterally and frontally. They are provided with a connection plug which facilitates assembly and maintenance operations. The standard length of the photocell connecting cable is FC13 600mm; the operating temperature range ensuring the longest life of flame sensors (approximately 50,000 hours) is comprised between 0°C and +60°C. FC14 FC14L Sensitivity The sensitivity of photocells can be identified through the colour of their casing, according to the following directions: /N Black /R Red /A Blue /V Green The colour red indicates photocells with standard sensitivity, the colour blue corresponds to the most sensitive photocells, whereas the colour green marks the least sensitive photocells. For the right coupling between photocell and control device please refer to our technical literature regarding control devices making use of these flame sensors. 4073_r01 1/2 Followings are the sensitivity ranges of the available flame - FC13 ∅17.5 sensors: FC7/R 1,5..5,5 lux Lateral side FC7/A 1,5..3,0 lux ∅8.5 FC7/V 3,0..5,5 lux 43 66.7 FC8/R 1,5..5,5 lux Fig.2 Frontal side FC8/A 1,5..3,0 lux - FC14 FC8/V 3,0..5,5 lux ∅ 17.5 FC9/N 1,5..5,5 lux 43,5 ∅8.5 Lateral side FC9/A 1,5..3,0 lux 61 FC9/V 3,0..5,5 lux - FC14L ∅17.5 Frontal and lateral side FC11/N 1,5..6,5 lux FC11/A 1,5..3,0 lux ∅8.5 100 Frontal and lateral side FC13/R 1,5..6,5 lux 117.5 FC13/A 1,5..3,0 lux Fig.3 Frontal and lateral side FC14/R 1,5..6,5 lux Drilling plane FC11 FC14/A 1,5..3,0 lux ∅8.5 Frontal and lateral side FC14L/R 1,5..6,5 lux FC14L/A 1,5..3,0 lux 17 17 34 FC7, FC8 e FC9 models - FC7 e FC9 FC13 and FC14 drilling plane (fastening system for the 5 4,4 6.9 19 mechanical interference with the photocell case) 2 46 34 ∅17 ∅14.2 17 15.6 24,5 34,7 46 - FC8 Ø4mm screws are recommended to fasten FC7, FC8, FC9 5 4,4 6.9 18,5 and FC11 flame sensors. 46 34 ∅17 Accessories 17 The cable for FC14 and FC14/L photocells is an accessory. 24,5 46.5 The standard cable length is 620mm (cables having different Fig.1 length are available upon request). Drilling plane FC7, FC8 e FC9 ∅17.5 17 17 The photocells can be provided upon request with a protection cap for the detecting element to protect it against 34 damage in case of impact FC11, FC13 e FC14 Models - FC11 5 4,4 29.8 12 ∅8.5 46 29.5 14.75 19 24.2…

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Satronic Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The Satronic Cell FC 8/R is a burner control unit designed for industrial flame detection and burner management. It features frontal flame sensor sensitivity ranging from 1.5–5.5 lux depending on configuration, an operating temperature range of 0°C to +60°C, and a standard connecting cable length of 600 mm. 3G Electric sources and supplies this equipment to support Singapore and Southeast Asia industrial operations with full delivery handling.

Frequently Asked Questions

Where can I buy a Satronic Cell FC 8/R burner control in your region?

3G Electric supplies the Satronic Cell FC 8/R and handles delivery to your location, your location, and surrounding regions. We manage all logistics, customs documentation, and USD invoicing for seamless procurement.

What is the flame sensor life of the Cell FC 8/R?

The Satronic Cell FC 8/R flame sensor is rated for approximately 50,000 hours of operation, ensuring extended service intervals and reduced maintenance costs for industrial burner applications.

What flame sensitivity range does the Cell FC 8/R provide?

The Cell FC 8/R offers frontal flame sensor sensitivity from 1.5 to 5.5 lux depending on configuration, allowing precise flame detection tuning for various burner types and fuel applications.

Used in

Common applications for Satronic
Steam boiler systems — Satronic MZ770S photocell and ZT870 transformer for flame detection and ignition control.
Industrial gas furnaces — Satronic IRD820 infrared photocell and control modules for continuous flame supervision during high-temperature processes.
Oil and gas burner retrofit — Satronic replacement photocell connectors and transformers for upgrading legacy burner safety systems.
Commercial heating equipment — Satronic burner control assemblies in air heaters and unit heaters for building HVAC systems.
Process heater automation — Satronic flame-fail relays and photocell harnesses in thermal-oil and hot-water heating loops.
Preventive maintenance programs — Satronic spare-parts kits stocked for scheduled photocell and transformer replacement in high-availability industrial facilities.

Satronic Products

3G Electric supplies Satronic burner controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Cell FC13R (replaced by FT13-V)
Satronic
Cell FC13R (replaced by FT13-V)
Satronic
Satronic
Cell FC11 (replaced by FT11-V)
Satronic
Satronic
Cell QRA 10C
Blue cell FC13A (replaced by FT13-V)
Satronic
Blue cell FC13A (replaced by FT13-V)
Cell for 530
Satronic
Cell for 530
Cell for 552-553
Satronic
Cell for 552-553

More from Satronic

View all Satronic parts
Satronic
Satronic
Relay CM 391-2 Frisquet
High sensitivity UV bulb
Satronic
High sensitivity UV bulb
Satronic
Satronic
IRD 1020 cell axial blue (oil and gas)
Relay RMO 8853 C2
Satronic
Relay RMO 8853 C2
Satronic
Satronic
Relay DMG 970-N MOD.03
Satronic
Satronic
Relay SM 592.2 TW1.5/TS5
Satronic
Satronic
Relay CM 381N.4 TW5/TS5
Satronic
Satronic
Relay MG569-BWZG (replaces 568 SE)