The Pactrol Relay MA 610 is a burner control unit designed for single-phase or three-phase operation at 220 V or 380 V, 50 Hz. It accommodates a flame cell type 8206 with minimum cell illumination of 30 Lux and…

SKU 3G-CBM-05934

Also listed as: REL 30106 · REL-30106

Brand
Pactrol
Item
Relay MA 610
Category
Burner Controls
UNSPSC
40101833 — Boiler or heater igniter
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

Pactrol
phase
single-phase or three-phase with neutral
voltage
220 V or 380 V
frequency
50 Hz
flame cell
8206
equipment power
8 VA
maximum flow rate
30 kgh
pre ignition time
10 sec
regulator setting
±10%, -15%
signaling current
2 A
post ignition time
6–10 sec
standard reference
NTC 2089
motor power triphase
0.75 kW
pre ventilation time
10 sec
motor power monophase
0.25 kW
minimum cell illumination
30 Lux
ignition transformer power
400 VA
maximum ambient temperature
40 °C

Datasheet Content

MA 610 - 710 - 810 - 910 SCHEMAS DE RACCORDEMENT Ligne Thermostat op gS d'ambiance = = a pa pa aN eS Disjoncteur |® 2) @ sy Neutre fy @ Signalisation | tension réseau LOOOOOO} | I] = Aquastat fh In ua Chaudiére | d’ allumage --- PAGE BREAK --- NOTICE D’ INSTRUCTIONS RENSEIGNEMENTS TECHNIQUES Utilisation en courant 220¥ ou 380V mondphasé ou triphasé avee neutre Fréquence Pulssance nominale monophasé du mobeur triphasé du transformateur d'allumage Eclairement minimum de la cellule Signalisation Tampérature ambiante maximum permise Equipement Cevlule Consommation en marche normale DIAGRAMME DE FONCTIONNEMENT — A ~ Démarrage normal avec allumage C¢ ~ Démarrage sans allumage Réquloteur Matour broleur Alluenoge Flectrovonew Flamme Sécume zed : Préventilation et préallumage Temps de sécurité Post allumage 410% -15% 50 Hz 0, 25 Kw 0,75 Kw 400 VA 30 Lux 2A 40°¢ mc BVA equipement MIA 610 NOTICE NTC 2089 Forte cellule 8206 Tamporisation Préventilation 10 sec.x Préallumege 10 sec.* 6 sec, - 10 Kgh Post allumage 10 sec. - 30 Kgh Sécurité : 20 sec. pour br@leur @ébit maxi : 10 Kgh 10 see. pour braleur débit maxi : 30 Kgh ® Ces temps sont variables avec Ja tension d'alimentation et Ia température ambiante, B - Extinction de flamme avec réallutnage D - Extinction de flamme sans réallumage Z = : Durée d'allumage B : Marche normale Page 19 --- PAGE BREAK --- SCHEMA DE PRINCIPE SANS PREVENTILATION AVEC PREVENTILATION lie §~ es oH us 4 r I | | \! | il i| | | {oF ecthl | Ba2 | it i et mt | | —_— a Peery 11 “= C oe So ; Alimentation réscau S : Signulisation tension réseau LS : Limiteur sécurité M =: Moteur braleur TH : Thermostat @ambiance EY : Electro-vannie Cc : Cellule Cl ; Relais moteur TA : Teanafermatcur @'allumage C2 =: Relais flamme [ SCHEMA DE RACCORDEMENT pee SANS PREVENTILATION AVEC PREYENTILATION “eo : AHmentation M_ : Moteur TA : Transfo d'allumage Cc : Cellule EV : Electro-vannie § : Signalisation LS ; Limiteur de récurité TH : Thermostat Page 20

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Pactrol Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The Pactrol Relay MA 610 is a burner control unit designed for single-phase or three-phase operation at 220 V or 380 V, 50 Hz. It accommodates a flame cell type 8206 with minimum cell illumination of 30 Lux and delivers equipment power of 8 VA. The control manages pre-ventilation, pre-ignition, and post-ignition timing at 10 sec, 10 sec, and 6–10 sec respectively, with a maximum flow rate of 30 kgh and regulator setting of ±10%, −15%. Motor power is 0.25 kW (single-phase) or 0.75 kW (three-phase), ignition transformer power 400 VA, signaling current 2 A, and maximum ambient temperature 40 °C. Compliant to standard NTC 2089. 3G Electric sources and supplies this control for burner installations across Singapore and Southeast Asia.

Frequently Asked Questions

Where can I buy the Pactrol Relay MA 610 in your region?

Order from 3G Electric (www.3g-electric.com.ph). We deliver to your location, your location, and CALABARZON. 3G Electric handles customs documentation, logistics, and USD invoicing. Lead time on request.

What is the lead time for the Pactrol Relay MA 610?

Lead time depends on stock availability in our your region warehouse and supplier replenishment cycles. Contact 3G Electric for a quote with current delivery schedule. We arrange all import logistics and customs clearance.

What flame cell type does the Relay MA 610 accept?

The Pactrol Relay MA 610 accommodates flame cell type 8206 with minimum illumination of 30 Lux. Equipment power is 8 VA. Pre-ventilation, pre-ignition, and post-ignition timing are factory-set per NTC 2089 standard.

Used in

Common applications for Pactrol
Industrial gas burners 10–60 kW — Pactrol Box P 16 FI and Control Box P 16 DIS spark-ignition controllers with 12 kV output and EN 298 approval
Atmospheric heating boilers — CSS01 12SJ control housing with integrated time and flame relays for safe ignition sequencing and flame detection
Forced-air burner retrofits — Pactrol connector assemblies (Molex, 10-terminal, P25) for panel rewiring and fuel-valve interface upgrades
Microgas fuel-valve integration — P25 connectors with resistors (e.g., GV2 96121) for seamless connection to Microgas proportional and solenoid valves
OEM control-panel assembly — Pactrol ignition modules and connectors for custom burner-control panels in packaged heating and combustion equipment
Plant-floor equipment replacement — Spare connectors and control housings stocked in Singapore for same-day delivery to maintenance teams across Southeast Asia

Pactrol Products

3G Electric supplies Pactrol burner controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Relay MA 26
Pactrol
Relay MA 26
Pactrol
Pactrol
Relay MA 41
Pactrol
Pactrol
Relay MA 52
Pactrol
Pactrol
MA 86.11 relay

More from Pactrol

View all Pactrol parts
Pactrol
Pactrol
Relay MA 55
Pactrol
Pactrol
Relay MA 810
Pactrol
Pactrol
Relay MA 72
Pactrol
Pactrol
Relay MA 45
Pactrol
Pactrol
Relay MA 803
Pactrol
Pactrol
Relay MA 23
Pactrol
Pactrol
Relay MA 310
Pactrol
Pactrol
Relay MA 43