Satronic Relay LFS1.21A2

Satronic LFS1.21A2 is a flame safeguard relay for burner control systems, operating at 120V AC or 230V AC, 50/60 Hz with double insulation and peak leakage current of 2.7 mA. Suitable for industrial combustion safety…

SKU 3G-CBM-05854

Also listed as: REL 15190 · REL-15190

Brand
Satronic
Item
Relay LFS1.21A2
Category
Burner Controls
UNSPSC
40101833 — Boiler or heater igniter
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

Satronic
type
Flame safeguard LFS1.21A2
voltage
120V AC / 230V AC
frequency
50/60 Hz
insulation
Double insulation
peak leakage current
2.7 mA

Datasheet Content

7 782 Flame safeguard LFS1... Flame safeguard with approval for continuous operation for the supervision of oil flames and gas flames in applications with an ionization probe and a photocell detector RAR9. Flame safeguard for intermittent operating mode with UV flame detectors QRA2 / QRA2M / QRA4 / QRA4M / QRA10 / QRA10M. LFS1 and this Data Sheet are intended for OEMs using the LFS1 in or on their products. Use, features Use LFS1 units are designed for the supervision of oil burners and gas burners in combination with control unit LEC1, burner control LME39.xxxRP, or with programmable logic controllers. Typical fields of application range from industrial burners up to the highest security level SIL3 and in the field of ship burners. Flame supervision: - Takes place with photocell detector RAR9 with approval for continuous operation, in the case of LFS1.1 (firing on oil). - Takes place with an ionization probe with approval for continuous operation or with UV flame detector QRA2 / QRA2M / QRA4 / QRA4M / QRA10 / QRA10M in intermittent operation, in the case of LFS1.2 (firing on gas). Building Technologies CC1N7782en 18.04.2018 Use, features The flame detectors are used in conjunction with control unit LEC1 or with freely programmable controllers in the following applications: - Dual supervision of burners / supervision of the main flame or of the ignition and main flame by 2 flame safeguards with the same or different flame detectors - Multiflame supervision / plants with several burners whose flames must be supervised individually by one or several flame detectors, but whose startup and supervision is carried out centrally and simultaneously by only one control unit - The flame safeguards are also used as flame indication units in combustion plants with manual startup Features - Flame signal display via multicolor LED signal lamp - Flame signal display via DC 0...10 V output signal (display only) - Can be parameterized via BCI communication interface - Potential-free signal contacts with double insulation - Undervoltage detection Supplementary documentation ASN Title Documentation Document type number LEC1 Control unit CC1N7761 Data Sheet Connection accessories for small AGK11.7 CC1N7201 Data Sheet burner controls AZL21 / AZL23 Display and operating units CC1N7542 Data Sheet LFS1 Flame safeguard CC1A7782 User documentation PC software for microprocessor Installation and Operating ACS410 controlled burner controls and CC1J7352 Instructions flame safeguards BCI interface between flame OCI410 CC1N7616 Data Sheet safeguard and PC QRA4 / QRA4M UV flame detector CC1N7711 Data Sheet QRA2 / QRA2M UV flame detector CC1N7712 Data Sheet QRA10 / QRA10M RAR9 Photocell detector CC1N7713 Data Sheet 2/40 Building Technologies CC1N7782en 18.04.2018 Warning notes To avoid personal injury or damage to property or the environment, the following warning notes must be observed. Do not open, interfere with, or modify the unit. ∂ All activities (mounting, installation, service, etc.) must be performed by qualified staff. ∂ Before making any wiring changes in the connection area, completely isolate the plant from mains supply (all-polar disconnection). Ensure that the plant cannot be inadvertently switched on again and that it is indeed dead. If this is not observed, there is a risk of electric shock ∂ Take suitable measures to provide protection against accidental contact at the electrical connections. If this is not observed, there is a risk of electric shock ∂ Press the lockout reset button / operation button of the LFS1 or the AGK20 lockout reset button extension only manually (applying a force of ′10 N) without using any tools or pointed objects. If this is not observed, there is a risk of loss of safety functions and a risk of electric shock ∂ Units must not be put into operation after a fall or shock, as this can adversely affect the safety functions even if the units do not exhibit any external signs of damage. If this is not observed, there is a risk of loss of safety functions and a risk of electric shock ∂ Each time work has been carried out (mounting, installation, service, etc.), check that the wiring is correct. If this is not observed, there is a risk of loss of safety functions and a risk of electric shock ∂ The mains-powered ionization probe does not offer protection against electric shock hazards. Protection against accidental contact must be ensured. If this is not observed, there is a risk of electric shock ∂ An ignited UV tube is a source of UV radiation. If the flame is supervised by optical flame detectors, both detectors must be placed in a way that ensures there is no direct visual contact between them. If this is not observed, there is a risk of loss of safety functions ∂ Connection of UV flame detectors QRA2M and QRA10M is only permitted if additional module AGK30 is used. Additional module AGK30 must always be connected within plug-in base AGK11.7 in terminal areas 1…7. If this is not observed, there is a risk of loss of safety functions and a risk of electric shock ∂ The data line for the AZL2 or other accessories, such as the OCI410 (plugs into the BCI interface), must only be connected or disconnected when the unit is dead (all- polar disconnection), since the BCI interface does not ensure safe separation from the mains voltage. If this is not observed, there is a risk of electric shock ∂ Intermittent operation: For safety reasons – self-test of the flame supervision circuit, etc. – at least one controlled shutdown must take place every 24 hours for applications with LFS1.2... and UV flame detectors QRA2 / QRA2M / QRA4 / QRA4M / QRA10 / QRA10M. If this is not observed, there is a risk of loss of safety functions ∂ The separating element supplied can be installed in the area between connection terminals 9, 10, 11, and 12, and the other terminals (1...7) as a means of achieving double insulation; refer to the Installation notes chapter. It is particularly important that the wiring is handled and installed correctly and as specified in the area around the terminals. If this is not observed, there is a risk of loss of safety functions and a risk of electric shock ∂ The 0...10 V voltage output terminal 7 is not double-insulated from the mains voltage. It is important to bear this in mind when selecting measuring equipment (at least CAT III). If this is not observed, there is a risk of electric shock 3/40 Building Technologies CC1N7782en 18.04.2018 Standards and certificates Only in conjunction with Applied directives: the flame detectors ∂ Low Voltage Directive 2014/35/EU ∂ Pressure Equipment Directive 2014/68/EC ∂ Gas Appliances Regulation (EU) (EU) 2016/426 ∂ Electromagnetic Compatibility EMC (immunity) *) 2014/30/EU *) The compliance with EMC emission requirements must be checked after the flame safeguard is installed in equipment Compliance with the regulations of the applied directives is verified by the adherence to the following standards / regulations: ∂ Automatic burner control systems for burners and DIN EN 298 appliances burning gaseous or liquid fuels ∂ Safety and control devices for burners and appliances DIN EN 13611 burning gaseous and/or liquid fuels — General requirements ∂ Automatic electrical controls for household and similar use DIN EN 60730-2-5 Part 2-5: Particular requirements for automatic electrical burner control systems The edition of the standards that applies in each case can be found in the declaration of conformity. Β…

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Satronic Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Satronic LFS1.21A2 is a flame safeguard relay for burner control systems, operating at 120V AC or 230V AC, 50/60 Hz with double insulation and peak leakage current of 2.7 mA. Suitable for industrial combustion safety applications.

Frequently Asked Questions

Where can I buy a Satronic LFS1.21A2 relay in your region?

3G Electric supplies the Satronic LFS1.21A2 flame safeguard relay with delivery to your location. We handle all logistics, customs clearance, and customs import processing. Contact us for pricing and lead-time confirmation.

What is the lead time for the Satronic LFS1.21A2?

Lead time on request. 3G Electric sources the LFS1.21A2 to order and manages all your region import formalities, including customs documentation and USD invoicing. Contact our team for your specific delivery schedule.

What voltage options does the Satronic LFS1.21A2 support?

The LFS1.21A2 operates at 120V AC or 230V AC, 50/60 Hz. It features double insulation and peak leakage current of 2.7 mA, meeting industrial combustion safety standards for burner control systems.

Used in

Common applications for Satronic
Steam boiler systems — Satronic MZ770S photocell and ZT870 transformer for flame detection and ignition control.
Industrial gas furnaces — Satronic IRD820 infrared photocell and control modules for continuous flame supervision during high-temperature processes.
Oil and gas burner retrofit — Satronic replacement photocell connectors and transformers for upgrading legacy burner safety systems.
Commercial heating equipment — Satronic burner control assemblies in air heaters and unit heaters for building HVAC systems.
Process heater automation — Satronic flame-fail relays and photocell harnesses in thermal-oil and hot-water heating loops.
Preventive maintenance programs — Satronic spare-parts kits stocked for scheduled photocell and transformer replacement in high-availability industrial facilities.

Satronic Products

3G Electric supplies Satronic burner controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Satronic
Satronic
Relay LME 41 091C2
Satronic
Satronic
Relay LME 21 130C2
Satronic
Satronic
Relay LME 41 054C2
Satronic
Satronic
LME 22 232C2 relay
Satronic
Satronic
Relay SM 152.2
Satronic
Satronic
SM 11F relay

More from Satronic

View all Satronic parts
Satronic
Satronic
Relay CM 391-2 Frisquet
High sensitivity UV bulb
Satronic
High sensitivity UV bulb
Satronic
Satronic
IRD 1020 cell axial blue (oil and gas)
Relay RMO 8853 C2
Satronic
Relay RMO 8853 C2
Satronic
Satronic
Relay DMG 970-N MOD.03
Satronic
Satronic
Relay SM 592.2 TW1.5/TS5
Satronic
Satronic
Relay CM 381N.4 TW5/TS5
Satronic
Satronic
Relay MG569-BWZG (replaces 568 SE)