We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

ESA ECS driver card 90/260 single - Ignition Systems
ESAIgnition Systems

ESA ECS driver card 90/260 single

ESA ECS driver card 90/260 single is an ignition system controller for industrial combustion equipment, supporting fieldbus voltage up to 25 VDC and ECS line lengths to 200 m. IP10 rated with DIN rail 35 mm EN 50022…

SKU 3G-CBM-03415

Also listed as: ESA 12004 · ESA-12004

Brand
ESA
Item
ECS driver card 90/260 single
Category
Ignition Systems
UNSPSC
40101833 — Boiler or heater igniter
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

ESA
mounting
DIN rail 35 mm EN 50022
ecs line length m
max 200
protection degree
IP10
fieldbus voltage vdc
max 25
storage temperature c
-10 to 70
operating temperature c
0 to 50
data transmission speed baud
max 9600

Datasheet Content

Electronic Serial communication interface for Esa Estro ESA ECS-DRIVER (E7081 rev. 02 - 30/08/2016) ESA ECS-DRIVER - E7081 rev. 02 - 30/08/16 GENERAL WARNINGS: DISPOSAL: ¾ All installation, maintenance, ignition and setting must To dispose of the product, abide by the local legislations be performed by qualified staff, respecting the norms regarding it. present at the time and place of the installation. GENERAL NOTES: ¾ To avoid damage to people and things, it is essential to observe all the points indicated in this handbook. The reported indications do not exonerate the Client/User from observing general or specific laws concerning acci- dents and environmental safeguarding. ¾ In accordance to the internal policy of constant quali- ty improvement, ESA-PYRONICS reserves the right to modify the technical characteristics of the present docu- ¾ The operator must wear proper DPI clothing (shoes, ment at any time and without warning. helmets...) and respect the general safety, prevention and precaution norms. ¾ It is possible to download technical sheets which have been updated to the latest revision from the ¾ To avoid the risks of burns or high voltage electrocu- www.esapyronics.com website. tion, the operator must avoid all contact with the burner and its control devices during the ignition phase and ¾ The products manufactured by ESA-PYRONICS while it is running at high temperatures. have been created in conformity to the UNI EN 746- 2:2010 Norms: Equipment for industrial thermal process ¾ All ordinary and extraordinary maintenance must be - Part 2: Safety requirements for combustion and the movement and treatment of combustible elements. This performed when the system is stopped. norm is in harmony with the Machine Directive 2006/42/CE. It is certified that the products in question ¾ To assure correct and safe use of the combustion respect all the requirements prescribed by the above plant, it is of extreme importance that the contents of this mentioned Norms and Directives. document be brought to the attention of and be meticu- lously observed by all personnel in charge of controlling ¾ Certified in conformity with the UNI EN ISO 9001 and working the devices. Norm by DNV GL. ¾ The functioning of a combustion plant can be dange- CERTIFICATIONS: rous and cause injuries to persons or damage to equip- ment. Every burner must be provided with certified com- bustion safety and supervision devices. ESA ECS-DRIVER is in compliance with European Union directi- ves and standards: 2014/30/EU (electromagnetic compatibility) ¾ The burner must be installed correctly to prevent any 2014/35/EU (low voltage), IEC 61000-6-4, IEC 61000-6-2, IEC type of accidental/undesired heat transmission from the 61000-3-2, CEI EN 55014-1 and CEI EN 60204-1 (EMC electro- flame to the operator or the equipment. magnetic compatibility, safety of machinery - electrical equipment of machines: general requirements). ¾ The performances indicated in this technical docu- The products conform to the requests for the Euroasian market (Russia, Belarus and Kazakhstan). ment regarding the range of products are a result of experimental tests carried out at ESA-PYRONICS. The tests have been performed using ignition systems, flame ASSISTANCE/CONTACTS: detectors and supervisors developed by ESA-PYRO- NICS. The respect of the above mentioned functioning conditions cannot be guaranteed if equipment, which is not present in the ESA-PYRONICS catalogue, is used. Headquarters: International Sales: Esa S.p.A. Pyronics International s.a. ESA PLEX-COM1 is in compliance with European Union directi- Via Enrico Fermi 40 Zoning Industriel, 4ème rue ves and standards: 2004/108/EC (electromagnetic compatibility) 2006/95/EC (low voltage), EN 61000-4-2, EN 61000-4-4, EN 24035 Curno (BG) - Italy B-6040 Jumet - Belgium 61000-4-5 and EN 61000-4-11 (electromagnetic compatibility: Tel +39.035.6227411 Tel +32.71.256970 conducted and radiated emissions, ESD, burst, surges and Power Fax +32.71.256979 fails immunity). Fax +39.035.6227499 [email protected] [email protected] www.esapyronics.com www.esapyronics.com 2 ESA ECS-DRIVER - E7081 rev. 02 - 30/08/16 ESA ECS-DRIVER-S F7081I02 ESA ECS-DRIVER-D F7081I01 ESA ECS-DRIVER is a serial communication interface CHARACTERISTICS that allows any control device to communicate with instruments equipped with an ECS (Esa Communication GENERAL: System) input. The ECS bus has a good immunity to electromagnetic disturbances, exploiting high levels of ¾ Power supply voltage: 90 ÷ 240 Vac electrical signal and medium communication speeds; it ¾ Power supply frequency: 40 to 70 Hz provides for the parallel connection of all devices, ¾ Maximum absorption: 40 VA allowing the mixed use of busbars and cable routes, with ¾ Temperature of operation: 0 ÷ 50 ° C the added advantage of being able to connect or ¾ Storage temperature: -10 ÷ 70 ° C disconnect the devices without having to close the ¾ Fixing: on DIN rail 35 mm (EN 50022) communication ring. ¾ Mounting position: any ¾ Protection degree: IP10 ¾ Work environment: not suitable for explosive APPLICATIONS or corrosive environments ¾ DRIVER-S size: 175X125x80 mm ¾ EIA-RS-232 or EIA-RS-422 interface converter at ¾ DRIVER-D size: 260X125x80 mm ¾ ECS DRIVER-S mass: 600 g ECS interface. ¾ Communication interface for ESA ESTRO and ESA ¾ ECS DRIVER-D mass: 750 g ¾ ECS fieldbus voltage: max 25Vdc REFLAM. ¾ ECS bus relay. ¾ Data transmission speed: max 9600 baud ¾ ECS line length: max 200m with ECS cable or with a busway ¾ Connectable devices for active output: max 70 4800 baud max 60 9600 baud www.esapyronics.com 3 ESA ECS-DRIVER - E7081 rev. 02 - 30/08/16 DESCRIPTION The ECS bus provides a MASTER-SLAVE DIN rail to be positioned in electrical panels, placed near communication to a single active interface for each the master controller or located on the system. The segment of the serial line. If the application finds a higher power supply section, consisting of the ESA ALIM-1 number of devices than the one supported by the active universal power supply (switching), accepts a wide ECS output, ESA ECS-DRIVER can be used as a signal range of supply voltage ensuring the functionality of the repeater. The connection to the control device can be interface in hostile environments. All connections are made using the EIA-RS-232 interface or the EIA-RS-422 performed using quick-release connectors, which interface (selectable via jumper), with HALF DUPLEX facilitate wiring or maintenance operations. ESA ECS- communication and without hardware control signals. DRIVER has two LEDs that indicate the direction of the The ECS signal to the bus is taken from the active data flow on the serial line: one is activated when the output. ESA ECS-DRIVER is supplied on attachment for interface transmits, while the second one is received. COMMUNICATION SPEED The choice of communication speed depends on several any changes or settings. The important thing is the factors: the number of connected devices, the type of setting of the same speeds between the controller and application, the expected wiring, and the environmental peripherals. The number of devices that can be factors that can disturb the flow of data with more evident connected to the active ECS output varies according to effects at high speeds. ESA ECS-DRIVER allows the…

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

ESA Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

ESA ECS driver card 90/260 single is an ignition system controller for industrial combustion equipment, supporting fieldbus voltage up to 25 VDC and ECS line lengths to 200 m. IP10 rated with DIN rail 35 mm EN 50022 mounting, it suits retrofit and new installations requiring reliable ignition management.

Frequently Asked Questions

Where can I buy ESA ECS 90/260 driver cards in your region?

3G Electric sources ESA ECS 90/260 ignition controller cards for delivery to your location. Lead time on request. We handle customs documentation, USD invoicing, and full logistics support for industrial equipment to your site.

What is the maximum ECS line length for the ESA ECS 90/260?

The ESA ECS 90/260 supports ECS line lengths up to 200 m, making it suitable for retrofit and new combustion system installations where ignition controls must span larger equipment footprints or cabinet-to-burner distances.

What voltage and mounting standard does this ignition driver card use?

The ESA ECS 90/260 accepts fieldbus voltage up to 25 VDC and mounts on DIN rail 35 mm EN 50022 standard. Operating temperature range is 0–50°C with IP10 protection degree for industrial combustion control environments.

Used in

Common applications for ESA
Oil-fired industrial boilers and furnaces — ESA UV2 photoelectric flame sensor and ESTRO C microprocessor controller for persistent flame monitoring
Gas burner safety interlocks — ESA ESTRO B-V2 and Genio 230 V with ionization-electrode probe for rapid flame-out detection and solenoid shutdown
Modular burner-control cabinets — ESA ECS driver cards (single/dual) with RS-232/RS-422 fieldbus integration for multi-burner supervisory systems
Retrofit ignition upgrades — ESA ESTRO Q exchange controller (second-generation replacement) for existing 115/230 V installations requiring IP54 environmental rating
Process-heating equipment — ESA microprocessor burner controls rated EN298 for permanent operation in industrial dryers, ovens, and thermal-recovery units
Burner-mounted electrode and probe assemblies — ESA UV2 cell support with 3/4″ gas connection and 280–400 V probe conditioning for integrated flame detection

ESA Products

3G Electric supplies ESA ignition systems. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Thermal unit for overload protection in motor starters and contactors. Provides 20 trip class response to prevent motor damage from sustained overcurrent in industrial electrical systems
EATON
Thermal unit for overload protection in motor starters and contactors. Provides 20 trip class response to prevent motor damage from sustained overcurrent in industrial electrical systems
Bimetallic overload relay element for motor starters and contactors. Provides 20 Trip Class response, tripping within 20 seconds at 600% of rated current to protect motors from sustained overcurrent conditions in industrial electrical systems
EATON
Bimetallic overload relay element for motor starters and contactors. Provides 20 Trip Class response, tripping within 20 seconds at 600% of rated current to protect motors from sustained overcurrent conditions in industrial electrical systems
Thermal overload relay unit for motor starters and contactors. Provides Class 20 trip protection, tripping within 20 seconds at 600% of rated current. Used to safeguard motors from sustained overcurrent conditions in industrial electrical systems
EATON
Thermal overload relay unit for motor starters and contactors. Provides Class 20 trip protection, tripping within 20 seconds at 600% of rated current. Used to safeguard motors from sustained overcurrent conditions in industrial electrical systems
Thermal unit for overload protection in motor starters and contactors. Provides Class 20 trip protection, tripping within 20 seconds at 600% of rated current. Suitable for safeguarding motors in industrial electrical systems
EATON
Thermal unit for overload protection in motor starters and contactors. Provides Class 20 trip protection, tripping within 20 seconds at 600% of rated current. Suitable for safeguarding motors in industrial electrical systems
Thermal overload relay component for motor starters and contactors, providing protection against sustained overcurrent conditions. Suitable for use in industrial automation, HVAC, and pump systems
EATON
Thermal overload relay component for motor starters and contactors, providing protection against sustained overcurrent conditions. Suitable for use in industrial automation, HVAC, and pump systems
Thermal unit for overload relay used in motor protection. Provides Class 20 trip protection against sustained overcurrent. Compatible with EATON motor starters and contactors
EATON
Thermal unit for overload relay used in motor protection. Provides Class 20 trip protection against sustained overcurrent. Compatible with EATON motor starters and contactors

More from ESA

View all ESA parts
ESA Genio 230 V 50/60HZ
ESA
ESA Genio 230 V 50/60HZ
ESA
ESA
Card EXP2 230V
ESA
ESA
ESTRO B -V2 110 Volt
ESA
ESA
Standard exchange ESTRO C (second generation)
ESA
ESA
EXP2 card 115V (for grey Estro box)
ESA
ESA
SPAC 33
ESA
ESA
Exchange standard ESTRO Q
ESA
ESA
Blue isolator