Dwyer Average temperature sensor TE-AAG-D2434-00

Dwyer average temperature sensor TE-AAG-D2434-00 measures fluid and gas temperatures from -40 to +150°C with DIN class B accuracy of ±0.3°C at 0°C. Features a 10 cm cable and selectable capillary lengths up to 60 cm…

SKU 3G-CBM-02292

Also listed as: DWY 45024 · DWY-45024

Brand
Dwyer
Item
Average temperature sensor TE-AAG-D2434-00
Category
Measurement
UNSPSC
41112412 — Pressure gauge
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

Dwyer
sensor type
Average temperature sensor
accuracy rtd
DIN class B ±0.3°C @ 0°C
cable length
10 cm
housing material
UL 94 V-0 polycarbonate
capillary lengths
15, 30, 60 cm
temperature range
-40 to +150°C
accuracy thermistor
±0.22°C @ 25°C

Datasheet Content

Série TE-A Capteurs de température moyenne Disponibles pour une Longueur de 15, 30 et 60 cm 2X Ø.875 Ø3.295 AVAILABLE 2X Ø.742 2X .325 X .2000 LENGTHS: MOUNTING SLOTS 6 FT, 12 FT, Ø.375 24 FT 4.163 4.788 .125 2.201 GASKET La Série TE-A de Capteurs de Température moyenne est utilisé pour mesurer la SPÉCIFICATIONS température dans les conduites larges et les unités de traitement de l’air. Les capillaires en Précision : aluminium pliable sont disponibles pour une longueur de 15, 30 et 60 cm pieds. Ces capillaires Capteur de température de thermistance : ± 0.22°C @ 25°C ; sont disponibles en quatre thermistances de capteurs RTD qui sont calibrés en interne pour livrer un Capteur de température RTD : DIN classe B : ±0.3°C @ 0°C. signal de sortie unique. La Série de montage CC1 est disponible pour fixer les capillaires à la paroi Limites de Température : -40 à +150°C. de la conduite ou de l’unité de traitement de l’air sans entortiller les fils du capteur à l’intérieur de Longueurs de Capillaire : 15, 30 et 60 cm (en fonction du modèle). la sonde. Pour une installation plus rapide, le boîtier présente de nombreux orifices prépercés, de Longueur de Câble : 10 cm. larges oreilles de fixation ainsi qu’un couvercle dévissable avec blocage. Courbes du Capteur : Voir Courbes de Résistance pour Séries TE. Matériau de la Sonde : Sonde en aluminium pliable. ACCESSOIRES Matériau du Boîtier : Répond aux exigences UL, 94 V-0 plastique polycarbonate. CC1-N, Clip pour Capteurs de Température Moyenne, Naturel (DWY46002) Poids : 397 g. CC1-B, Clip pour Capteurs de Température Moyenne, Beige (DWY46004) CC1-GY, Clip pour Capteurs de Température Moyenne, Gris (DWY46006) Longueur Longueur Modèle Type de Capteur Réf. Modèle Type de Capteur Réf. de Capillaire de Capillaire TE-AAG-A0634-00 10K Type III NTC Thermistance 15 DWY45002 TE-AAG-D0634-00 Pt100 RTD 15 DWY45020 TE-AAG-A1234-00 10K Type III NTC Thermistance 30 DWY45004 TE-AAG-D1234-00 Pt100 RTD 30 DWY45022 TE-AAG-A2434-00 10K Type III NTC Thermistance 60 DWY45006 TE-AAG-D2434-00 Pt100 RTD 60 3G-CBM-02292 TE-AAG-B0634-00 10K Type II NTC Thermistance 15 DWY45008 TE-AAG-E0634-00 Pt1000 RTD 15 DWY45026 TE-AAG-B1234-00 10K Type II NTC Thermistance 30 DWY45010 TE-AAG-E1234-00 Pt1000 RTD 30 DWY45028 TE-AAG-B2434-00 10K Type II NTC Thermistance 60 DWY45012 TE-AAG-E2434-00 Pt1000 RTD 60 DWY45030 TE-AAG-C0634-00 3K NTC Thermistance 15 DWY45014 TE-AAG-F0634-00 20K NTC Thermistance 15 DWY45032 TE-AAG-C1234-00 3K NTC Thermistance 30 DWY45016 TE-AAG-F1234-00 20K NTC Thermistance 30 DWY45034 TE-AAG-C2434-00 3K NTC Thermistance 60 DWY45018 TE-AAG-F2434-00 20K NTC Thermistance 60 DWY45036

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Dwyer Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Dwyer average temperature sensor TE-AAG-D2434-00 measures fluid and gas temperatures from -40 to +150°C with DIN class B accuracy of ±0.3°C at 0°C. Features a 10 cm cable and selectable capillary lengths up to 60 cm, housed in UL 94 V-0 polycarbonate for industrial process monitoring applications.

Frequently Asked Questions

Where can I source the Dwyer TE-AAG-D2434-00 temperature sensor worldwide?

3G Electric supplies the Dwyer TE-AAG-D2434-00 as an authorized distributor with worldwide delivery. Lead time and logistics are confirmed on request. Contact our team for availability and customs handling support.

What temperature range and accuracy does the Dwyer TE-AAG-D2434-00 offer?

This Dwyer sensor measures -40 to +150°C with DIN class B accuracy of ±0.3°C at 0°C and ±0.22°C at 25°C. It meets industrial process monitoring standards for fluid and gas temperature measurement.

What cable and capillary options are available for this Dwyer temperature sensor?

The TE-AAG-D2434-00 includes a 10 cm fixed cable and selectable capillary lengths of 15 cm, 30 cm, or 60 cm. Housing is UL 94 V-0 polycarbonate for durability in industrial environments.

Used in

Common applications for Dwyer
Combustion air-filter monitoring — Magnehelic Series 2000 on burner air-intake filter banks
Clean-room and pharmaceutical pressurisation — Magnehelic / Capsuhelic differential-pressure gauges
HVAC fan-discharge static pressure — Mark II inclined-vertical manometers on AHU test points
Filter-blockage alarms — Photohelic Series 3000 combined gauge/switch on air-handling units
BMS-integrated pressure monitoring — Digihelic DH3 with 4–20 mA output for building management

Dwyer Products

3G Electric supplies Dwyer measurement. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
This 1/16 DIN digital temperature controller accepts thermocouple types J, K, and T. It operates on 100 to 240V AC input and provides an SSR output rated at 3.5 A. The unit features P control mode and includes a relay alarm (3A, SPST). Typical applications include temperature regulation in ovens, furnaces, and packaging equipment
Dwyer
This 1/16 DIN digital temperature controller accepts thermocouple types J, K, and T. It operates on 100 to 240V AC input and provides an SSR output rated at 3.5 A. The unit features P control mode and includes a relay alarm (3A, SPST). Typical applications include temperature regulation in ovens, furnaces, and packaging equipment
The Dwyer SCD-PS is a power supply accessory designed for use with the Dwyer Series SCD temperature controller. It supports expandability from one to eight process control loops, suitable for applications such as HVAC, process heating, and environmental chambers. Overall dimensions: 1 3/8 in width, 2 7/8 in length
Dwyer
The Dwyer SCD-PS is a power supply accessory designed for use with the Dwyer Series SCD temperature controller. It supports expandability from one to eight process control loops, suitable for applications such as HVAC, process heating, and environmental chambers. Overall dimensions: 1 3/8 in width, 2 7/8 in length
This temperature sensor is a replacement accessory for RITTAL Blue e+ Cooling Units and Chillers. It monitors internal enclosure temperature to support proper cooling system operation in electrical enclosures
RITTAL
This temperature sensor is a replacement accessory for RITTAL Blue e+ Cooling Units and Chillers. It monitors internal enclosure temperature to support proper cooling system operation in electrical enclosures
Thermal unit for overload protection in motor starters and contactors. Provides 20 Trip Class response to safeguard motors against sustained overcurrent conditions in industrial electrical systems
EATON
Thermal unit for overload protection in motor starters and contactors. Provides 20 Trip Class response to safeguard motors against sustained overcurrent conditions in industrial electrical systems
Thermal unit for overload protection in motor starters and contactors. Provides a 20 Trip Class response, tripping within 20 seconds at 600% of rated current to safeguard motors from overheating
EATON
Thermal unit for overload protection in motor starters and contactors. Provides a 20 Trip Class response, tripping within 20 seconds at 600% of rated current to safeguard motors from overheating

More from Dwyer

View all Dwyer parts
Magnehelic pressure gauge 2000-30PA
Dwyer
Magnehelic pressure gauge 2000-30PA
Flow meter FS 2
Dwyer
Flow meter FS 2
Dwyer
Dwyer
Average flow probe PAFS-1002
Dwyer
Dwyer
MAFS-48 metallic average flow probe
Dwyer
Dwyer
Transmitter 645-6
Dwyer
Dwyer
Current detector SCS-211125-R
Dwyer
Dwyer
Current transmitter SCT10-102
Dwyer
Dwyer
Current transmitter CCT 50-203