Dwyer Thermowell TE-TNS-N064N-14

Dwyer thermowell designed for temperature measurement in industrial processes, featuring a 381 mm probe length and IP66 protection rating. Offers 1/4" and 1/2" NPT connections with 15 cm cable for reliable sensor…

SKU 3G-CBM-02269

Also listed as: DWY 42006 · DWY-42006

Brand
Dwyer
Item
Thermowell TE-TNS-N064N-14
Category
Measurement
UNSPSC
41112412 — Pressure gauge
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

Dwyer
weight g
150.3
connection npt
1/4" / 1/2"
cable length cm
15
probe length mm
381
protection index
IP66

Datasheet Content

Sondes de température conduites ou immersion Série TE Série TE PROBE LENGTH + .75 +.0625/ -.000 BALL CHAIN CONNECTOR 4.00 ±.050 PROBE LENGTH + .366 +.0625/ -.000 ø3.295 4X ø.875 PROBE LENGTH + .75 +.0625/ -.000 8 FOOT 2.216 PLENUM GENERAL CABLE PURPOSE (2.813 WEATHERPROOF) PROBE LENGTH + .55 BALL CHAIN + .0625/-.000 2X .325 x .2000 CONNECTOR MOUNTING PROBE 4X SLOTS LENGTH ø.875 .125 4.00 ±.050 + .336 ø3.295 GASKET + .0625/-.000 PROBE LENGTH + .55 + .0625/-.000 ø.235 4.788 .125 8 FOOT .125 4.163 GASKET 2.216 GASKET PLENUM GENERAL CABLE PURPOSE 1.000 (2.813 WEATHERPROOF) 2X ø 218 1.500 MOUNTING 2.000 HOLES Les sondes de température Série TE installables sur conduites et immersibles SPÉCIFICATIONS permettent de surveiller la température de l’air ou de l’eau dans l’ensemble d’un système de Précision : domotique ou d’une unité de gestion de la circulation d’air. Les sondes montées sur brides - Capteur de température thermistance : ±0.22°C @ 25°C. sur les conduites surveillent l’air en entrée ou en sortie, et envoient au contrôleur numérique - Capteur de température RTD : Classe B DIN : ±0.3°C @ 0°C. un signal de thermistance ou de RTD. Les sondes immergées, fournies avec des garnitures de Plage de température : Fonctionnement - 40 @ 150°C. compression, servent typiquement à surveiller les conduites d’eau chaudes ou réfrigérée du Courbes de capteur : Voir la table résistance / température. système de domotique. Les doigts de gants sont recommandées, mais non nécessaires sur les Boîtier : UL, plastique polycarbonate 94 V-O. sondes immergées. Pour les applications à volume d’air variables, la série TE peut être configurée Indice de protection : IP66 (DFW, IBW seulement). avec un câble inifugé de 20 cm avec câble souple. Les unités standard ont des câbles de 10 cm Poids : 150,3 g. avec un bloc de connecteurs intégral pour ne pas avoir à utiliser d’écrous supplémentaires pour fixer les câbles. Les modèles en boîtier comportent plusieurs trous d’accès pour offrir un accès Doigts de gants facile à la conduite depuis tous les côtés du boîtier. Le couvercle à quart de tour comporte une chaînette pour éviter de le perdre pendant l’installation. Connection Modèle Length Réf. (Internal/External) (NPT) Exemple TE -DFN -A 04 4 8 -00 TE-DFN-A0448-00 TE-TNS-N044N-14 10 cm 1/4˝ / 1/2˝ DWY42002 Séries TE Sonde de température DFN Sonde seule TE-TNS-N044N-12 10 cm 1/2˝ / 3/4˝ DWY42004 DFG Sonde avec boîtier TE-TNS-N064N-14 15 cm 1/4˝ / 1/2˝ 3G-CBM-02269 DFW Sonde avec boîtier IP66 Configuration TE-TNS-N064N-12 15 cm 1/2˝ / 3/4˝ DWY42008 IBN Sonde immersion IBG Sonde immersion avec boîtier TE-TNS-N094N-14 23 cm 1/4˝ / 1/2˝ DWY42010 IBW Sonde immersion IP66 A Thermistance 10K de type 3 TE-TNS-N094N-12 23 cm 1/2˝ / 3/4˝ DWY42012 B Thermistance 10K de type 2 TE-TNS-N124N-14 30 cm 1/4˝ / 1/2˝ DWY42014 Type C Thermistance 3K Ohm de capteur D RTD PT100 Ohm TE-TNS-N124N-12 30 cm 1/2˝ / 3/4˝ DWY42016 E RTD PT1000 Ohm F Thermistance 20K 25 5 cm 04 10 cm Longueur 06 15 cm de la sonde 08 20 cm 12 30 cm 18 45 cm (DFN/DFG seulement) Diamètre 4 1/4˝ - 6,35 mm de la sonde Câble de 4 10 cm connexion 8 20 cm inifugé 00 Aucune option Taille 12 1/2˝ NPT connexion 14 1/4˝ NPT

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Dwyer Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Dwyer thermowell designed for temperature measurement in industrial processes, featuring a 381 mm probe length and IP66 protection rating. Offers 1/4" and 1/2" NPT connections with 15 cm cable for reliable sensor integration in process control applications.

Frequently Asked Questions

Where can I buy the Dwyer TE-TNS-N064N-14 thermowell worldwide?

3G Electric supplies the Dwyer TE-TNS-N064N-14 thermowell globally as an authorised distributor. We handle logistics, customs clearance, and delivery to your location. Lead time on request.

What are the key specifications of this Dwyer thermowell?

The Dwyer TE-TNS-N064N-14 features a 381 mm probe length, IP66 protection rating, 1/4" and 1/2" NPT threaded connections, and a 15 cm integrated cable. Weight is 150.3 g.

What is the lead time for the Dwyer TE-TNS-N064N-14?

Lead time varies based on availability and destination. Contact 3G Electric for a specific delivery schedule. We source worldwide and manage all shipping logistics to ensure reliable supply.

Used in

Common applications for Dwyer
Combustion air-filter monitoring — Magnehelic Series 2000 on burner air-intake filter banks
Clean-room and pharmaceutical pressurisation — Magnehelic / Capsuhelic differential-pressure gauges
HVAC fan-discharge static pressure — Mark II inclined-vertical manometers on AHU test points
Filter-blockage alarms — Photohelic Series 3000 combined gauge/switch on air-handling units
BMS-integrated pressure monitoring — Digihelic DH3 with 4–20 mA output for building management

Dwyer Products

3G Electric supplies Dwyer measurement. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Dwyer
Dwyer
Thermowell TE-TNS-N044N-14
Thermowell TE-TNS-N124N-14
Dwyer
Thermowell TE-TNS-N124N-14
Dwyer
Dwyer
Thermowell TE-TNS-N044N-12
Dwyer
Dwyer
Thermowell TE-TNS-N063N-00
Thermowell TE-TNS-N124N-12
Dwyer
Thermowell TE-TNS-N124N-12
Dwyer
Dwyer
Thermowell TE-TNS-N043N-00

More from Dwyer

View all Dwyer parts
Magnehelic pressure gauge 2000-30PA
Dwyer
Magnehelic pressure gauge 2000-30PA
Flow meter FS 2
Dwyer
Flow meter FS 2
Dwyer
Dwyer
Average flow probe PAFS-1002
Dwyer
Dwyer
MAFS-48 metallic average flow probe
Dwyer
Dwyer
Transmitter 645-6
Dwyer
Dwyer
Current detector SCS-211125-R
Dwyer
Dwyer
Current transmitter SCT10-102
Dwyer
Dwyer
Current transmitter CCT 50-203