We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

Image not available
DwyerMeasurement

Dwyer Temperature humidity probe WHT-322

The Dwyer WHT-322 is a temperature-humidity probe delivering 0 to 10 VDC output for HVAC and environmental monitoring applications. It features 3% humidity accuracy and operates across -20 to 60°C with NEMA 3S (IP54)…

SKU 3G-CBM-02157

Also listed as: DWY 12008 · DWY-12008

Brand
Dwyer
Item
Temperature humidity probe WHT-322
Category
Measurement
UNSPSC
41112412 — Pressure gauge
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

Dwyer
sensor type
10K Thermistor (Dwyer Curve A)
output signal
0 to 10 VDC
enclosure rating
NEMA 3S (IP54)
housing material
ABS
humidity accuracy
3%
temperature range
-4 to 140°F (-20 to 60°C)
power requirements
10 to 35 VDC

Datasheet Content

146_Layout 2 7/2/12 3:39 PM Page 146 Series WHT Weather-Resistant Humidity/ Temperature Transmitter Compact Housing, Sintered Filter 2X 5/16 [7.94] 3-31/64 [88.5] 4-9/16 1-27/64 1-31/64 [115.89] 3 [36.12] [37.70] AIR QUALITY [76.2] 4 [101.6] 2-3/4 [69.85] The Compact Series WHT Humidity/Temperature Transmitter is designed to SPECIFICATIONS 0 to 10 V Output Models: withstand the elements. A removable sintered filter protects the polymer capacitance Relative Humidity Range: 0 to 100% Power requirements: 15 to 35 VDC sensor from solid objects that may come in contact with the transmitter. The transmitter RH. or 15 to 29 VAC; is available with 4 to 20 mA or 0 to 10 VDC output signals for both temperature and Temperature Range: -40 to 140°F Output signal: 0 to 10 V @ 5 mA humidity. This transmitter is ideal for measuring outside air temperature and humidity (-40 to 60°C). max. levels for air handling economizer applications. Accuracy, RH: ±3% 20 to 80% RH, 0 to 5 V Output Models: ±4% @ 10-20%, 80 to 90%. Power requirements: 10 to 35 VDC Accuracy, Temp Models with 4 to 20 or 10 to 29 VAC; Model Accuracy RH Output Temperature Humidity/Temperature mA Temp. Output: ±0.9°F @ 72°F Output signal: 0 to 5 V @ 5 mA max. WHT-310 3% 4 to 20 mA None (±0.3°C @ 25°C). Response Time: 15 seconds. WHT-311 3% 4 to 20 mA 4 to 20 mA Accuracy, Temp Models with Passive Electrical Connections: Removable WHT-320 3% 0 to 10 V None Thermistor Temp Sensor: ±0.36°F @ screw terminal block. WHT-322 3% 0 to 10 V 0 to 10 V 77°F (±0.2°C @ 25°C). Drift: <1% RH/year. Transmitters WHT-330 3% 0 to 5 V None Hysteresis, RH: ±1%. RH Sensor: Capacitance polymer. WHT-333 3% 0 to 5 V 0 to 5 V Repeatability, RH: ±0.1% typical. Temperature Sensor: 4 to 20 mA WHT-31A 3% 4 to 20 mA 10 K Ohm Temperature Limits: -40 to 140°F output, solid state band gap. Passive WHT-32A 3% 0 to 10 V 10 K Ohm (-40 to 60°C). output: 10K @ 25°C thermistor (Dwyer Note: For 2% accuracy, change the leading 3 to a 2. Storage Temperature: -40 to 176°F curve A). (For example, WHT-210) (-40 to 80°C). Enclosure: ABS. Compensated Temperature Range, Enclosure Rating: Designed to meet RH: -4 to 140°F (-20 to 60°C). NEMA 3S (IP54). 4 to 20 mA Loop Powered Models: Weight: 0.3 oz (8.5 g). Power requirements: 10 to 35 VDC; Agency Approvals: CE. Output signal: 4 to 20 mA. Model ™ AQS-1 AQStick Ambient Volatile Organic Compound Monitor Powered by USB Port, Local Indication 2-1/64 [51.31] 49/64 3/8 [19.64] [9.59] 2-15/64 [56.81] The AQStick™ Ambient Volatile Organic Compound (VOC) Monitor monitors SPECIFICATIONS ambient air quality by detecting the VOC content in the air. Some common sources of VOC VOC’s Detected: Alcohols, aldehydes, ketones, organic acids, aliphatic and aromatic contamination are carpets, building materials, paints, cleaners, and tobacco smoke. Even hydrocarbons. low concentrations of these compounds can affect building occupants’ comfort. A computer’s Sensor: MEMS metal oxide semiconductor. USB port provides power for the sensor and the LED lights which change color in Power: Powered from PC USB port. accordance with the ambient air quality. In order to correspond with ASHRAE’s standards Temperature Limits: 32 to 122°F (0 to 50°C). for air quality, the VOC reading from the monitor is converted from a percentage Humidity Limits: 5 to 95% RH (non-condensing). contaminated to an equivalent PPM reading of CO2. The percentage contaminated Agency Approval: CE. multiplied by 2000 PPM of CO2 gives the equivalent concentration of CO2. From the factory, the LED is green under 1000 PPM CO2, yellow for 1000 to 1500 PPM CO2 and red above 1500 PPM CO2. These factory values can be changed using the free online software. When using the free online software, the AQStick™ ambient VOC monitor can log and graph how Model AQS-1, Ambient Volatile Organic Compound Monitor building conditions change over time. AQStickTM is a trademark of Dwyer Instruments, Inc. 146 DWYER INSTRUMENTS, INC. | www.dwyer-inst.com Série WHT Transmetteur d’humidité et de température étanche Boîtier Compact, Filtre Fritté 2X 5/16 [7.94] 3-31/64 4-9/16 [88.5] 1-27/64 1-31/64…
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Dwyer Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The Dwyer WHT-322 is a temperature-humidity probe delivering 0 to 10 VDC output for HVAC and environmental monitoring applications. It features 3% humidity accuracy and operates across -20 to 60°C with NEMA 3S (IP54) protection, fitting industrial control and building management systems.

Frequently Asked Questions

Where can I buy the Dwyer WHT-322 temperature-humidity probe?

Order the Dwyer WHT-322 from 3G Electric, an authorised distributor with worldwide delivery and logistics support. We handle customs clearance and ship globally to your facility. Lead time on request.

What is the lead time for the Dwyer WHT-322?

The Dwyer WHT-322 is available to order with lead time confirmed upon request. 3G Electric arranges shipment worldwide, managing all logistics and documentation to your location.

What output signal does the Dwyer WHT-322 provide?

The Dwyer WHT-322 delivers 0 to 10 VDC output, compatible with standard HVAC control systems and building management platforms. It requires 10 to 35 VDC power supply and operates from -20 to 60°C.

Used in

Common applications for Dwyer
Combustion air-filter monitoring — Magnehelic Series 2000 on burner air-intake filter banks
Clean-room and pharmaceutical pressurisation — Magnehelic / Capsuhelic differential-pressure gauges
HVAC fan-discharge static pressure — Mark II inclined-vertical manometers on AHU test points
Filter-blockage alarms — Photohelic Series 3000 combined gauge/switch on air-handling units
BMS-integrated pressure monitoring — Digihelic DH3 with 4–20 mA output for building management

Dwyer Products

3G Electric supplies Dwyer measurement. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Dwyer
Dwyer
Humidity temperature probe WHT-320
Dwyer
Dwyer
Temperature humidity probe WHT-333
Dwyer
Dwyer
Temperature humidity probe WHT-330
Temperature humidity probe WHT-32A
Dwyer
Temperature humidity probe WHT-32A
Temperature humidity probe WHT-310
Dwyer
Temperature humidity probe WHT-310
Dwyer
Dwyer
Temperature humidity probe WHT-311

More from Dwyer

View all Dwyer parts
Magnehelic pressure gauge 2000-30PA
Dwyer
Magnehelic pressure gauge 2000-30PA
Flow meter FS 2
Dwyer
Flow meter FS 2
Dwyer
Dwyer
Average flow probe PAFS-1002
Dwyer
Dwyer
MAFS-48 metallic average flow probe
Dwyer
Dwyer
Transmitter 645-6
Dwyer
Dwyer
Current detector SCS-211125-R
Dwyer
Dwyer
Current transmitter SCT10-102
Dwyer
Dwyer
Current transmitter CCT 50-203