We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

Image not available
DwyerMeasurement

Dwyer Transmitter 616K-14-TC

The Dwyer 616K-14-TC is a pressure transmitter for HVAC and building automation systems, measuring 0-250 Pa with 4-20 mA or 0-10 V output. It features IP10 protection and accepts 3 mm or 5 mm barbed tubing…

SKU 3G-CBM-02125

Also listed as: DWY 04210 · DWY-04210

Brand
Dwyer
Item
Transmitter 616K-14-TC
Category
Measurement
UNSPSC
41112412 — Pressure gauge
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

Dwyer
output
4-20 mA / 0-10 V
ip rating
IP10
cable gland
2.9-6.4 mm diameter
pressure range
0-250 Pa
connection process
barbed, dual size for 3mm and 5mm tubing
connection electrical
screw terminal block

Datasheet Content

Série 616KD Transmetteur de pression différentielle Séries 616KD Solution économique pour les applications domotiques, étalonnage par bouton-poussoir numérique avec technologie One Touch® Couvercle optionnel OPTIONAL TERMINAL COVER 5/16 [7.94] 5/8 [15.88] 3-21/64 R [84.53] 2-13/32 [61.12] Ø5/32 [3.97] MOUNTING HOLE 1/2 7/8 2 PLACES [12.70] [22.23] 2-1/4 [57.15] 1-1/2 1-1/32 [38.10] [26.19] 2-13/32 [61.12] Bouton One Touch® réglage du zéro et de l’intervalle Le transmetteur de pression différentielle Séries 616KD et 6160T sont SPÉCIFICATIONS conçues dans un souci de simplicité, ce qui fait d’eux le choix idéal pour les installateurs. Fluides : Air et gaz non-combustibles et compatibles. ,E TRANSMETTEUR DE PRESSION DIFFÏRENTIELLE /NE 4OUCH® sont des sondes économiques et Matériaux : Consulter l’usine. compactes qui réduisent les coûts initiaux et les frais de fonctionnement. Ces instruments Précision : ±2% P.E. Stabilité : ±1% P.E./an. PRESSION non seulement évitent les encombrants potentiomètres rotatifs présents dans la plupart des Limites de température : 0 à +50°C. autres transmetteur, mais éliminent entièrement d’avoir à parcourir l’intervalle de l’instrument Limites de pression : 13,8 kPa. pour l’étalonnage. Un bouton-poussoir permet d’étalonner correctement le zéro et l’intervalle, Effet thermique sur l’échelle : ±0.11% P.E./C type +0,19%. sans autre manœuvre. Aucune source supplémentaire de pression de référence et dispositif Effet thermique sur zéro : 616KD-X0: 1%/°C; 616KD-X1: 0.5%/°C; d’étalonnage distinct ne sont nécessaires ; pas besoin de le retirer pour l’envoyer dans 616KD-X2: 0.33%/°C; 616KD-X3: 0.2%/°C; 616KD-X4: 0.1%/°C FS max. UNLABORATOIRE,INSTALLATEURMETLUNITÏÌLAPRESSIONDERÏFÏRENCENULLE PUISPOUSSEUN Alimentation :   6$#  OU  lLS   6#!  lLS BOUTON  LE TRANSMETTEUR EST PRÐT Ì FONCTIONNER  ,E GAIN DE PS TEMEST ÏNORME AU COURS DU Signal de sortie : 4 à 20 mA, 0-10 volts, 0-5 volts. cycle d’utilisation du produit, par rapport aux sondes traditionnels qui exigent du temps pour Réglages de zéro et intervalle : Bouton -poussoir. la dépose chaque année et du temps supplémentaire pour un étalonnage complet à pleine Résistance de boucle :  OHMS MAX $#  OHMS MAX !#  ÏCHELLE ,E MONTAGE EST SIMPLE GRÊCE AUX TROUS DE MONTAGE +$ ETDUAUX ERGOTS DU Consommation électrique : 21 mA max. 4 INTÏGRÏS AU BOÔTIER MOULÏ ,A SÏRIE +$ POSSÒDE NECTEURS DES ÌCONVIS TS OUVERFACILES Connexions électriques : bloc de connecteurs à vis. à câbler sur le haut du boîtier, et la série 6160T possède un bloc de connecteurs démontable Entrée électrique : Presse-étoupe pour câble de diamètre 2,9 à 6,4 mm. commode qui permet à l’installateur de réaliser le câblage depuis l’extérieur, puis de remettre Connexions de processus : Dentelé, taille double pour raccorder des tubes de caoutchouc LE BLOC SUR LATECARÌ LINTÏRIEUR DU  BOÔTIER ,A SÏRIE 4 A UN BOÔTIER )0 ,E TRANSMETTEUR ou vinyle de 3 mm et 5 mm. Boîtier : IP10. de pression différentielle One-Touch® conviennent parfaitement aux installations de domotique Orientation du support : Indifférente. Poids : 51 g. telles que gestion de la circulation d’air, pression de conduites, volume d’air variable et filtres. Homologation : CE - RoHs. RoHS ,ES MODÒLES DISPONIBLES VONT DE  0A Ì  0A ES SELON LES SÏRI Modèle Puissance Description Réf. ACCESSOIRES 616KD-10 4-20 mA - 0-10 V 0 à 250 Pa $79 A-302F-A, SONDE COUDÏE AVEC BRIDE $79 616KD-11 4-20 mA - 0-10 V 0 à 500 Pa $79 A-360, RAIL $). !LUMINIUM M $79 616KD-12 4-20 mA - 0-10 V 0 à 750 Pa $79 A-480, SONDE PLASTIQUE $79 A-489, SONDE INOX DROITE $79 616KD-13 4-20 mA - 0-10 V 0 à 1250 Pa $79 A-618, COUVERCLE DE PROTECTION TRANSMETTEUR $79 616KD-14 4-20 mA - 0-10 V 0 à 2500 Pa $79 616KD-10V 4-20 mA - 0-10 V 0 à 250 Pa $79 616KD-11V 4-20 mA - 0-10 V 0 à 500 Pa $79 616KD-12V 4-20 mA - 0-10 V 0 à 750 Pa $79 616KD-13V 4-20 mA - 0-10 V 0 à 1250 Pa $79 616KD-14V 4-20 mA - 0-10 V 0 à 2500 Pa $79

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Dwyer Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The Dwyer 616K-14-TC is a pressure transmitter for HVAC and building automation systems, measuring 0-250 Pa with 4-20 mA or 0-10 V output. It features IP10 protection and accepts 3 mm or 5 mm barbed tubing connections, fitting low-pressure monitoring applications.

Frequently Asked Questions

Where can I buy the Dwyer 616K-14-TC pressure transmitter worldwide?

Order from 3G Electric, an authorised distributor. We handle worldwide delivery, customs clearance, and logistics for the Dwyer 616K-14-TC transmitter. Lead time on request.

What are the output options for the Dwyer 616K-14-TC?

The transmitter provides dual output: 4–20 mA or 0–10 V. Choose based on your control system interface. Both outputs are factory-selectable via internal jumpers.

What tubing connections does the Dwyer 616K-14-TC accept?

The transmitter accepts barbed process connections for both 3 mm and 5 mm tubing, allowing flexible installation in existing HVAC ductwork and low-pressure monitoring circuits. Electrical connection is via screw terminal block.

Used in

Common applications for Dwyer
Combustion air-filter monitoring — Magnehelic Series 2000 on burner air-intake filter banks
Clean-room and pharmaceutical pressurisation — Magnehelic / Capsuhelic differential-pressure gauges
HVAC fan-discharge static pressure — Mark II inclined-vertical manometers on AHU test points
Filter-blockage alarms — Photohelic Series 3000 combined gauge/switch on air-handling units
BMS-integrated pressure monitoring — Digihelic DH3 with 4–20 mA output for building management

Dwyer Products

3G Electric supplies Dwyer measurement. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Dwyer
Dwyer
Transmitter 616KD-14V-TC
Dwyer
Dwyer
Transmitter 616K-11-TC
Dwyer
Dwyer
Transmitter 616K-13-TC
Dwyer
Dwyer
Transmitter 616K-12-TC
Transmitter 616KD-10V-TC
Dwyer
Transmitter 616KD-10V-TC
Transmitter 616KD-11V-TC
Dwyer
Transmitter 616KD-11V-TC

More from Dwyer

View all Dwyer parts
Magnehelic pressure gauge 2000-30PA
Dwyer
Magnehelic pressure gauge 2000-30PA
Flow meter FS 2
Dwyer
Flow meter FS 2
Dwyer
Dwyer
Average flow probe PAFS-1002
Dwyer
Dwyer
MAFS-48 metallic average flow probe
Dwyer
Dwyer
Transmitter 645-6
Dwyer
Dwyer
Current detector SCS-211125-R
Dwyer
Dwyer
Current transmitter SCT10-102
Dwyer
Dwyer
Current transmitter CCT 50-203