We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

Delta Pump VD2 LR1 single-tube - Oil Pumps
DeltaOil Pumps

Delta Pump VD2 LR1 single-tube

The Delta VD2 LR1 is a single-tube oil pump designed for industrial hydraulic and lubrication applications. Operating at 3500 rpm max with a pressure setting of 20 ±0.3 bar and return line pressure of 2 bar max, the…

SKU 3G-CBM-01922

Also listed as: DEL 20202 · DEL-20202

Brand
Delta
Item
Pump VD2 LR1 single-tube
Category
Oil Pumps
UNSPSC
40151524 — Oil pumps
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

Delta
type
VD2 LR1
nozzle port
G1/8"
hub diameter
32 mm
rotation speed
3500 rpm max
shaft diameter
8 mm
pressure setting
20 ±0.3 bar
standard strainer
Nylon mesh 150µ, 20cm²
return line pressure
2 bar max
inlet return connection
G1/4"

Datasheet Content

Oil burners fuel unit with pressure regulating Type VD www.deltapumps.com VD1 - V5 flanged Certified Quality System Printed in Italy - DE111/0404 Oil burners fuel unit with pressure regulating Type VD The DELTA fuel unit is an efficient modern oil burner pump with compact design and since its mounting flange, hub and shaft sizes are manufactured to 1 international standards (EN 225), it can be fitted to every oil burner. 9 1- Features 2 8 • High suction capability. • Suitable for one or two pipe systems. • Self priming. 7 • Reliable pressure and positive cut-off (two pipe). • Special rotary shaft seal. 3 • Silent operation. 4 • Low power absorption. • Easily installed and adjusted. 5 6 • Pressure and vacuum gauge ports. 2- Applications From the suction side, the gears pass the oil to the The DELTA fuel unit type VD is designed for pumping oil pressure chamber, where it comes up against the head in high pressure oil burners and transfer pump of the piston. Due to the build up of pressure, the piston applications. is forced back against the pressure regulating spring. The outlet to the nozzle port, which until this point has WARNING been sealed by the seat on the head of the piston, opens It must not be used to pump water or acid. and allows oil to flow through to the nozzle while the excess oil discharges to the return side (or by-passes in the one pipe version). It will be realized of course that 3- Operation the spring tension, which is varied by the regulating The VD fuel unit consists of a pump, filter and pressure screw (1), regulates the pressure of oil required. regulator/cut-off valve housed within one casting. The On shut down, the oil pressure of course immediately pumping action is obtained from two spur gears (2), one drops and in this instance the spring, which hitherto has of which is connected to the drive shaft (3). The pump been under compression, pushes the piston forward casting provides the various oil ways, for the suction (6), onto its seat, thereby cutting off the oil flow to the nozzle return (5) and nozzle (9) ports. Pressure (8) and vacuum outlet (two pipe version). (7) gauge ports are also provided. The VD unit is available in two pipe and one pipe In oil burner designs employing a magnetic valve in the version. Both versions are self priming. oil line circuit, the cut-off seat on the piston head is unnecessary and in these cases a "monotube" type On start up, the rotating gears purge the air from the piston must be used in the pump. This type of piston is suction chamber, through a vent groove in the piston to not fitted with a nozzle cut-off seat and its function is as the return line in two pipe version, and through the a pressure regulator and safety valve, for instance for nozzle line in one pipe version. On initial commissioning, expansion of pre-heated oil. it is possible to bleed the air more quickly, through the The pump can be converted from the single pipe version pressure gauge. to the two pipe version, fitting the by-pass plug (4) in the Because a vacuum now exists oil, due to atmospheric return port. pressure, enters the suction chamber through the filter. 2 Printed in Italy - DE111/0404 4- Pump identification VD 1 R L 2 4 U Pump type Nozzle capacity (see graphs) Rotation (seen from shaft end) R = clockwise L = counter clockwise Nozzle line (seen from cover) R = right L = left Pipes system 1 = one pipe 2 = two pipe Pressure ranges Factory setting 3 = 2 ÷ 10 bar 4 ±0,3 bar 4 = 4 ÷ 15 bar (Standard) 10 ±0,3 bar 5 = 8 ÷ 20 bar 15 ±0,3 bar 6 = 10 ÷ 25 bar 20 ±0,3 bar Special versions U = cover type U with 65 cm² stainless steel filter, mesh 110µ (standard on V5) without pressure and vacuum gauge (except V5) P = auxiliary pressure port 5- Technical Specifications Oil viscosity ………………………………… 1,2 ÷ 50 cSt Oil temperature …………………………….. 60°C max. Power consumption …………………….. See graphs Nozzle capacity……………………….…….. See graphs Suction line vacuum ………………………. 0,5 bar max. Suction line pressure ……………….…….. 2 bar max. Return line pressure ……………………… 2 bar max. Rotation speed ……………………….……. 3500 rpm max. Standard strainer…………………………… Nylon mesh 150µ, 20cm² (VD1 9 cm²) Dimensions (EN 225) ..……………………. Hub dia.32, shaft dia.8 Optional : flange hub dia. 54, shaft 7/16” Connections (ISO 228/1) ……………….… Inlet – Return : G1/4” Nozzle port : G1/8” Pressure – Vacuum gauge : G1/8” Weight ……………………………………….. gr. 950 3 Printed in Italy - DE111/0404 6- Diagrams Nozzle capacity Power consumption L/h Visc. 5 cSt (1.4°E) 2800 RPM 125 Visc. 5 cSt (1.4°E) Watts 2800 RPM 100 V5 200 VD4 75 VD4 150 V5 VD3 VD3 50 100 VD2 VD2 VD1 25 50 VD1 5 10 15 20 25 Bar 5 10 15 20 25 Bar 7- Overall dimensions 84 ÷ 94 20 1 9 Ø32 7 63 V P Ø8 40 Made in Italy 28 7 8 23 19 25 42 54 (46xVD1) 5 6 96 (88xVD1) 7 8 1 9 20 34.5 Ø54 Ø10.5 Ø8 7 Made in Italy 27.5 30.5 10 23 15 24 32 5 25 6 38 4 56 92 98 112 103 1 Pressure regulation 5 Return 6 Suction 7 Vacuum gauge 8 Pressure gauge 9 Nozzle port 10 Auxiliary pressure port 4 Printed in Italy - DE111/0404 8- By-pass installation To convert the DELTA fuel unit from the single pipe version to the two pipe version, do the following: a) Using a 19 mm wrench, remove the 1/4" plug from return port (Fig. 1). V P b)…

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Delta Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The Delta VD2 LR1 is a single-tube oil pump designed for industrial hydraulic and lubrication applications. Operating at 3500 rpm max with a pressure setting of 20 ±0.3 bar and return line pressure of 2 bar max, the unit features a nozzle port G1/8", inlet return connection G1/4", 32 mm hub diameter, and 8 mm shaft diameter. Standard equipment includes a nylon mesh strainer rated 150µ with 20 cm² filtration area. 3G Electric supplies this pump for Southeast Asia markets with full DDP delivery.

Frequently Asked Questions

Where can I buy the Delta VD2 LR1 single-tube oil pump worldwide?

Order the Delta VD2 LR1 from 3G Electric, an authorized distributor. We handle sourcing, customs clearance, and worldwide delivery. Lead time and freight terms available on request.

What is the lead time for the Delta VD2 LR1 pump?

Lead time depends on current availability and your location. Contact 3G Electric with your delivery address for a firm quote. We coordinate all logistics and customs documentation.

What pressure and speed does the Delta VD2 LR1 pump operate at?

The Delta VD2 LR1 operates at a maximum rotation speed of 3500 rpm with a pressure setting of 20 ±0.3 bar. Return line pressure is 2 bar max. Nozzle port is G1/8".

Used in

Common applications for Delta
Oil burner heating systems — Delta VM1 and VM2 fuel unit pumps delivering 35–55 l/h at 20 bar pressure setting
Industrial lubrication circuits — Delta A-series and A2-series pumps with 130 µm stainless steel strainers at 10 bar pressure
Hydraulic equipment integration — Delta AD-series pumps rated 3500 rpm with 32 mm hub diameter for modular system assembly
Burner nozzle supply — Delta fuel units with G1/8" nozzle port and solenoid valve integration for atomization control
Replacement pump specification — Delta cable assemblies (700 mm, 3-core) for retrofit and maintenance of existing burner equipment
Multi-stage heating plant operation — Delta VM2 models with 150 µm nylon filtration for continuous-duty burner fuel supply

Delta Products

3G Electric supplies Delta oil pumps. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Pump Accessories Valves & Regulation Motors & Drives All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Pump VM1 LR1.4 single-tube
Delta
Pump VM1 LR1.4 single-tube
Pump V2 LR 2,4
Delta
Pump V2 LR 2,4
Pump V1RL 2P
Delta
Pump V1RL 2P
Pump V1LR 2P
Delta
Pump V1LR 2P
Pump V1 LR 2.4
Delta
Pump V1 LR 2.4
Delta
Delta
Pump V3 LR 2.4

More from Delta

View all Delta parts
Delta
Delta
VM3 LL 2.4 pump
Delta
Delta
Cover joint V
Delta
Delta
Pump VM1 LL 2.4 2P
Delta
Delta
Sieve S
Delta
Delta
Universal pump VU2
Delta
Delta
Pump VM3 RL 2.4
Delta
Delta
24 V coil for VU1
Delta
Delta
Cap + seal for pump filter (type A)