Danfoss Thermostat RT 7

The Danfoss Thermostat RT 7 is a temperature-controlled single-pole changeover contact control designed for general purpose, marine, and industrial applications across Southeast Asia. This unit features an operating…

SKU 3G-CBM-01862

Also listed as: DAN 05006 · DAN-05006

Brand
Danfoss
Item
Thermostat RT 7
Category
Controls
UNSPSC
39121026 — Control power transformer
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

Danfoss
contact type
single-pole changeover contact, temperature-controlled
special versions
differential thermostats, adjustable neutral zone thermostats
bulb type options
ambient bulb, sheathed capillary tube, unsheathed capillary tube, cylindrical remote bulb
application categories
general purpose, marine, industrial
differential range rt9
2.2 → 10 °C
bulb temperature rating
150 °C
differential range rt10
1.7 → 7 °C
differential range rt13
1.5 → 6 °C
differential adjustment rt9
1 → 4.5 °C
differential adjustment rt10
1 → 3 °C
differential adjustment rt13
1 → 3 °C
capillary tube length options
2 m
differential range rt3 rt2 rt7
2.8 → 10 °C
operating temperature range rt8
−20 → 12 °C
operating temperature range rt9
−45 → −15 °C
operating temperature range rt10
−60 → −25 °C
operating temperature range rt13
−30 → 0 °C
differential adjustment rt3 rt2 rt7
1 → 4 °C
operating temperature range rt3 rt2 rt7
−25 → 15 °C

Datasheet Content

Fiche technique Thermostats Type RT Description Les thermostats RT comportent un contact inverseur unipolaire commandé par température. La position de ce contact est fonction de la température du bulbe et de la valeur de consigne. La série RT comprend des thermostats à usage général, maritime et industriel, y compris thermostats différentiels, thermostats à zone neutre réglable, ainsi que thermostats à bulbe d'ambiance, à bulbe au bout d’un capillaire gainé et à bulbe au bout d’un capillaire. Contenu Page Description ...............................................................................................................................................................................1 Récapitulatif des types de thermostats selon les plages de température.........................................................2 Caractéristiques techniques, tous les types..................................................................................................................3 Nomogrammes des différentiels ......................................................................................................................................5 Caractéristiques techniques ...............................................................................................................................................7 Homologations .......................................................................................................................................................................7 Dimensions et poids .............................................................................................................................................................8 Choix de poche à bulbe .......................................................................................................................................................8 Montage, réglage ...................................................................................................................................................................9 Fonctionnement .................................................................................................................................................................. 10 Charges ................................................................................................................................................................................... 11 Thermostats pour les installations de ventilation ................................................................................................... 12 Thermostats à zone neutre réglable ............................................................................................................................ 13 Thermostats différentiels.................................................................................................................................................. 14 Pièces et accessoires .......................................................................................................................................................... 15 INDUSTRIAL CONTROLS IC.PD.P10.E1.04 - 520B2251 Fiche technique Thermostats, type RT Thermostats type RT Plage −50 0 50 100 150 200 250 300°C pe Type bar −60 → −25 RT 10 Thermostats à bulbe à distance cylindrique −45 → −15 RT 9 −30 → 0 RT 13 −25 → 15 RT 3,2,7 −20 → 12 RT 8 −5 → 10 RT 12 −5 → 30 RT 14 −5 → 50 RT 26 5 → 22 RT 23 8 → 32 RT 15 25 → 90 RT 101 20 → 90 RT 106 30 → 140 RT 108 70 → 150 RT 107 120 → 215 RT 120 150 → 250 RT 123 200 → 300 RT 124 −50 → −15 RT 17 Thermostats à bulbe d’ambiance, de gaine ou capillaire −30 → 0 RT 11 −25 → 15 RT 34 −5 → 30 RT 4 10 → 35 RT 115 10 → 45 RT 103 15 → 45 RT 140 40 → 80 RT 141 25 → 90 RT 102 −20 → 12 RT 8L Thermostats à zone neutre réglable −5 → 30 RT 14L 0 → 38 RT 16L 15 → 45 RT 140 L 25 → 90 RT 101L Thermostats différentiels 0 → 15 RT 270 0 → 20 RT 271 2 IC.PD.P10.E1.04 - 520B2251 Fiche technique Thermostats, type RT Caractéristiques techniques A la commande, indiquer le type et le numero de Charges et numéros de code code A: Charge de vapeur: ne pas placer le bulbe dans une zone plus chaude que le boîtier. B: Charge à adsorption C: Charge quantitative: ne pas placer le bulbe dans une zone plus froide que le boîtier Thermostats à bulbe à distance cylindrique Versions conseillées Plage de la Plage différentielle Température Longueur № de code réglage réglable*) de bulbe du tube max. capillaire Réglage de Réglage de plage min. plage max. Type de Type…

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Danfoss Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The Danfoss Thermostat RT 7 is a temperature-controlled single-pole changeover contact control designed for general purpose, marine, and industrial applications across Southeast Asia. This unit features an operating temperature range of −25 → 15 °C, differential range of 2.8 → 10 °C, and differential adjustment of 1 → 4 °C, with bulb temperature rating to 150 °C. Available bulb options include ambient bulb, sheathed capillary tube, unsheathed capillary tube, and cylindrical remote bulb configurations with capillary tube lengths to 2 m; special versions include differential thermostats and adjustable neutral zone thermostats. 3G Electric supplies the RT 7 with full logistics and DDP handling for SG and regional delivery.

Frequently Asked Questions

Where can I source the Danfoss RT 7 thermostat worldwide?

3G Electric is an authorised Danfoss distributor supplying the RT 7 thermostat globally. We handle logistics, customs clearance, and delivery to your facility. Lead time on request—contact our team for availability and quotation.

What is the operating temperature range of the Danfoss RT 7?

The Danfoss RT 7 operates from −25 °C to +15 °C with a differential range of 2.8–10 °C. It features a single-pole changeover contact suitable for general purpose, marine, and industrial applications requiring precise temperature control.

What bulb options are available for the RT 7 thermostat?

The Danfoss RT 7 offers four bulb configurations: ambient bulb, sheathed capillary tube, unsheathed capillary tube, and cylindrical remote bulb. Bulb temperature rating up to 150 °C. Choose based on your installation environment and sensing requirements.

Used in

Common applications for Danfoss
Light-oil industrial burners — OD / OD-H nozzles as scheduled replacement parts
Heating-boiler oil-supply circuits — BFP 10L / 11L / 41L pumps and coupling kits
Burner-rack solenoid valves — EV and EVR series for oil and gas shut-off
Legacy plant troubleshooting — matching a failed burner nameplate to correct Danfoss nozzle/pump combination
Refrigeration pressure controls — KP / RT series for secondary-refrigerant loops

Danfoss Products

3G Electric supplies Danfoss controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Thermostat RT 107
Danfoss
Thermostat RT 107
Thermostat RT 106
Danfoss
Thermostat RT 106
RT 14 thermostat
Danfoss
RT 14 thermostat
Thermostat RT 103
Danfoss
Thermostat RT 103
Thermostat RT 101
Danfoss
Thermostat RT 101
Thermostat RT 4
Danfoss
Thermostat RT 4

More from Danfoss

View all Danfoss parts
Pressure switch RT 1A 0.8/5bar
Danfoss
Pressure switch RT 1A 0.8/5bar
Pressure switch RT 262 A
Danfoss
Pressure switch RT 262 A
Thermostat RT 34
Danfoss
Thermostat RT 34
Danfoss
Danfoss
Bulb pouch
Pressure switch RT 113
Danfoss
Pressure switch RT 113
Pressure switch RT 116
Danfoss
Pressure switch RT 116
Pressure switch RT 112
Danfoss
Pressure switch RT 112
Pressure switch RT 117
Danfoss
Pressure switch RT 117