We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

Image not available
DSZHHVAC Tools

DSZH Tracer all gas/fluorine oils 31004030

DSZH Tracer is a fluorescent refrigerant leak detection dye for HVAC systems compatible with CFC, HFC, HCFC, and PFC refrigerants. Applied at 4 ml per 0.5 kg refrigerant, it fluoresces red in daylight and blue-violet…

SKU 3G-CBM-01696

Also listed as: COR 55024 · COR-55024

Brand
DSZH
Item
Tracer all gas/fluorine oils 31004030
Category
HVAC Tools
UNSPSC
41112509 — Air velocity and temperature monitors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

DSZH
dosage
4 ml per 0.5 kg refrigerant
visibility
red fluorescent visible in daylight, blue-violet under UV light
application
refrigerant leak detection tracer dye
compatibility
CFC, HFC, HCFC, PFC refrigerants

Datasheet Content

MATERIAL SAFETY HIGHSIDE CHEMICALS, INC. DATA SHEET 11114 REICHHOLD ROAD GULFPORT, MS 39503 (228)-896-9220 TRACE II (R) THIS MSDS COMPLIES WITH 29 CFR 1900.1200 SECTION 1 - IDENTITY/EMERGENCY INFORMATION PRODUCT NAME: TRACE II (R) PRODUCT CODES: 21004 CHEMICAL NAME: MIXTURE 21016 CHEMICAL FORMULA: MIXTURE 21128 IN CASE OF AN EMERGENCY CALL 1-800-255-3924 SECTION 2 - INGREDIENTS COMPONENTS CAS NO. PEL/TLV - SOURCE AZO DYE 85-83-6 NOT ESTABLISHED ALL COMPONENTS OF THIS PRODUCT ARE LISTED ON THE U.S. TSCA INVENTORY SECTION 3 - PHYSICAL DATA VAPOR PRESSURE: LESS THAN 0.1 mmHg @ 20ΕC VAPOR DENSITY (AIR = 1): NOT APPLICABLE SPECIFIC GRAVITY (H2O = 1): 0.94-0.97 SOLUBILITY IN WATER: INSOLUBLE IN COLD WATER APPEARANCE AND ODOR: DARK RED OILY LIQUID. MILD DISTINCT ODOR. % VOLATILE (BY WT.): LESS THAN 0.7% SECTION 4 - FIRE AND EXPLOSION HAZARD DATA FLASH POINT (METHOD USED): 230-330ΕC (CLEVELAND OPEN CUP) EXPLOSIVE LIMITS: LOWER: NOT APPLICABLE EXTINGUISHING MEDIA: USE WATER FOG, FOAM, OR DRY CHEMICAL EXTINGUISHING MEDIA. SPECIAL FIRE FIGHTING PROCEDURES: FIREFIGHTERS SHOULD BE EQUIPPED WITH SELF- CONTAINED BREATHING APPARATUS AND TURN OUT GEAR. WATER MAY BE INEFFECTIVE BUT SHOULD BE USED TO KEEP EXPOSED CONTAINERS COOL. UNUSUAL FIRE AND EXPLOSION HAZARDS: AVOID ALL SOURCES OF IGNITION - HEAT, SPARKS, OPEN FLAME. HAZARD RATING: HEALTH - 1 FLAMMABILITY - 1 REACTIVITY - 0 TRACE II (R) 1 of 3 SECTION 5 - REACTIVITY DATA HAZARDOUS POLYMERIZATION: WILL NOT OCCUR STABILITY: STABLE HAZARDOUS DECOMPOSITION OR BYPRODUCTS: UNDER FIRE CONDITIONS: NOXIOUS FUMES, CARBON MONOXIDE, CARBON DIOXIDE, NOX, AND OTHER DECOMPOSITION PRODUCTS, IN THE CASE OF INCOMPLETE COMBUSTION. MATERIALS TO AVOID: STRONG OXIDIZERS, OXYGEN, LIQUID CHLORINE, SODIUM HYPOCHLORITE, CALCIUM HYPOCHLORITE, CAUSTIC OR ACIDIC SOLUTIONS. SECTION 6 - HEALTH HAZARD DATA CARCINOGENICITY: NO CONSTITUENT OF 0.1% OR GREATER IN THIS PRODUCT IS LISTED BY OSHA, NTP, OR IARC. PRIMARY ROUTE(S) OF ENTRY: INHALATION, EYE AND SKIN CONTACT POTENTIAL EFFECTS OF OVEREXPOSURE: EYE: MAY CAUSE EYE IRRITATION. SKIN: MINIMALLY IRRITATING, PROLONGED CONTACT CAN CAUSE DERMATITIS. INGESTION: DO NOT TAKE INTERNALLY. MAY CAUSE NAUSEA AND DIARRHEA. INHALATION: MAY CAUSE RESPIRATORY IRRITATION, CHEMICAL PNEUMONITIS. FIRST AID PROCEDURES: EYE CONTACT: IMMEDIATELY RINSE WITH RUNNING WATER FOR 15 MINUTES. IF IRRITATION DEVELOPS, GET MEDICAL ATTENTION. SKIN CONTACT: WASH AFFECTED AREAS WITH SOAP AND WATER. REMOVE AND LAUNDER CONTAMINATED CLOTHING BEFORE REUSE. IF IRRITATION DEVELOPS, GET MEDICAL ATTENTION. INGESTION: IF INGESTED, FORCE FLUIDS IF CONSCIOUS. DO NOT INDUCE VOMITING.CALL A PHYSICIAN IMMEDIATELY. INHALATION: IF AFFECTED, REMOVE INDIVIDUAL TO FRESH AIR, IF BREATHING IS DIFFICULT, ADMINISTER OXYGEN. IF BREATHING HAS STOPPED GIVE ARTIFICIAL RESPIRATION. KEEP PERSON WARM, QUIET AND GET MEDICAL ATTENTION IMMEDIATELY. SECTION 7 - SPECIAL PROTECTION RESPIRATORY PROTECTION: IF HIGH EXPOSURE LEVELS FROM MIST OR VAPOR, A NIOSH/MSHA APPROVED AIR SUPPLIED RESPIRATOR IS ADVISED. IN ABSENCE OF PROPER ENVIRONMENTAL CONTROL, ENGINEERING OR ADMINISTRATIVE CONTROLS SHOULD BE IMPLEMENTED TO REDUCE EXPOSURE. EYE PROTECTION: CHEMICAL SPLASH GOGGLES IN COMPLIANCE WITH OSHA REGULATIONS ARE ADVISED; HOWEVER, OSHA REGULATIONS ALSO PERMIT OTHER TYPE SAFETY GLASSES (ANSI Z87.1 OR EQUIVALENT). TRACE II (R) 2 of 3 VENTILATION: PROVIDE SUFFICIENT MECHANICAL (GENERAL AND/OR LOCAL EXHAUST) VENTILATION TO MINIMIZE EXPOSURE. PROTECTIVE GLOVES: WEAR RESISTANT GLOVES SUCH AS: NEOPRENE OTHER PROTECTIVE EQUIPMENT: TO PREVENT REPEATED EXPOSURE OR PROLONGED SKIN CONTACT, WEAR IMPERVIOUS CLOTHING OR BOOTS. SECTION 8 - ENVIRONMENTAL INFORMATION STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED: SMALL AND LARGE SPILL: SPILL SHOULD BE CONTAINED AND PLACED IN SUITABLE CONTAINERS FOR DISPOSAL. PREVENT RUN OFF TO SEWERS, STREAMS OR OTHER BODIES OF WATER. IF RUN OFF OCCURS, NOTIFY PROPER AUTHORITIES AS REQUIRED, THAT SPILL HAS OCCURRED. WASTE DISPOSAL METHOD: SMALL AND LARGE SPILL: DISPOSE OF IN ACCORDANCE WITH ALL LOCAL, STATE, AND FEDERAL REGULATIONS. THE FOLLOWING INFORMATION MAY BE USEFUL IN COMPLYING WITH VARIOUS STATE AND FEDERAL LAWS AND REGULATIONS UNDER VARIOUS ENVIRONMENTAL STATUTES: EPA REGULATION 302 (CERCLA SECTION 102): NO REPORTABLE QUANTITY (RQ) FOR PRODUCT OR ANY CONSTITUENT GREATER THAN 1% OR O.1% (CARCINOGEN). EPA REGULATION CFR 355 (SARA SECTION 301-302): NO THRESHOLD PLANNING QUANTITY FOR PRODUCT OR ANY CONSTITUENT GREATER THAN 1% OR 0.1% (CARCINOGEN). EPA REGULATION 40 CFR 372 (SARA SECTION 313): QUANTITY PRESENT IS NOT REPORTABLE. EPA REGULATION 40 CFR 370 (SARA SECTIONS 311-312): NOT APPLICABLE FOR PRODUCT. SECTION 9 - SHIPPING INFORMATION D.O.T (49 CFR 172): NOT REGULATED POISON CONSTITUENT: NONE BILL OF LADING: REFRIGERATION OIL IT 145000 S-2 INTERNATIONAL (UN/NA CODE): NONE DATE PREPARED: 06/06/96 DATE UPDATED:03/01/2007 WHILE HIGHSIDE CHEMICALS, INC. BELIEVES THE DATA SET FORTH HEREIN ARE ACCURATE AS OF THE DATE HEREOF, HIGHSIDE CHEMICALS, INC. MAKES NO WARRANTY WITH RESPECT THERETO AND EXPRESSLY DISCLAIMS ALL LIABILITY FOR RELIANCE THEREON. SUCH DATA ARE OFFERED SOLELY FOR YOUR CONSIDERATION, INVESTIGATION, AND VERIFICATION. TRACE II (R) 3 of 3 CODE ARTICLE 3G-CBM-01696 INSTRUCTIONS POUR L’UTILISATION DU « TRACE 2 » LIRE LES CONSIGNE DE SECURITE AVANT TOUTE UTILISATION - TRACE 2 est spécialement conçu pour détecter d’éventuelles fuites dans les circuits frigorifiques et les systèmes de climatisation. - A utiliser avec tout type de fluide frigorigène, y compris les fluides CFC, HFC, HCFC et PFC. - Le traceur rouge vif fluorescent permet de localiser les fuites avec précision. Le rouge vif est visible à la lumière du jour. - Le Bleu-violet fluorescent et vif apparaît en présence de lumière ultraviolette. - Toutes les sources de lumières ultraviolette conviennent. - Le film rouge vif et les traces fluorescentes perdurent jusqu’à ce qu’ils soient nettoyés. - TRACE 2 reste visible à travers la glace ou le gel CONSEILS D’UTILISATION - Appliquer une dose de TRACE 2, à raison de 4 ml par 0.5 Kg de fluide frigorigène dans le circuit. - Pour une plus forte intensité de couleur, ajouter une seconde dose identique à la première. TENIR HORS DE PORTEE DES ENFANTS
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

DSZH Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

DSZH Tracer is a fluorescent refrigerant leak detection dye for HVAC systems compatible with CFC, HFC, HCFC, and PFC refrigerants. Applied at 4 ml per 0.5 kg refrigerant, it fluoresces red in daylight and blue-violet under UV light for reliable leak location in air-conditioning and refrigeration equipment.

Frequently Asked Questions

Where can I buy DSZH Tracer 31004030 refrigerant leak detection dye?

Order from 3G Electric, an authorized DSZH distributor. We handle worldwide delivery and customs logistics for HVAC tools and refrigeration supplies. Lead time on request.

What is the correct dosage for DSZH Tracer 31004030?

Apply 4 ml of DSZH Tracer per 0.5 kg of refrigerant. The dye fluoresces red in daylight and blue-violet under UV light for precise leak location in air-conditioning and refrigeration equipment.

Which refrigerant types is DSZH Tracer 31004030 compatible with?

DSZH Tracer 31004030 works with CFC, HFC, HCFC, and PFC refrigerants. It is suitable for all standard HVAC and refrigeration systems using these refrigerant classes.

Used in

Common applications for DSZH
Split-system air-conditioner service: DSZH manifold bases and SAE/NPT reducers integrate with technician gauge sets for pressure monitoring and refrigerant charge.
Rooftop packaged unit maintenance: Flare connector caps, hose tips, and union fittings expedite field replacement of damaged lines and adapters on commercial cooling systems.
Refrigerant recovery and recycling: DSZH bottle adapters (R600A-rated) connect recovery cylinders to hose lines, enabling safe extraction of flammable and standard refrigerants.
Process-cooling loop installation: SAE straight male/female unions and reducers support temporary or permanent manifold assembly on industrial water-chilled equipment.
Heat-pump seasonal service: DSZH dudgeon extensions and adapter kits allow technicians to connect diagnostic gauges to restricted or recessed access ports on reversing-valve manifolds.
Field emergency repairs: Individual DSZH fittings stocked in stock allow technicians to repair or modify hose connections on-site without returning to the shop for components.

DSZH Products

3G Electric supplies DSZH hvac tools. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
DSZH
DSZH
Universal tracer 31004040
Single-dose tracer 31004036
DSZH
Single-dose tracer 31004036
DSZH
DSZH
Leak detector spray -40°C 31003030 400 ml
DSZH
DSZH
Nitrogen detergent 31006053
DSZH
DSZH
Leak detector spray Better Bubble 950 ml
Surface thermometer 29005024
DSZH
Surface thermometer 29005024

More from DSZH

View all DSZH parts
Transfer bottle 12kg gray CBM DO NOT RECOVER FULL BOTTLES
DSZH
Transfer bottle 12kg gray CBM DO NOT RECOVER FULL BOTTLES
DSZH
DSZH
Refrigerant bottle R404 800 GR (including deposit)
DSZH
DSZH
Dehydrating liquid 28.3G Thawzone
DSZH
DSZH
Heat strip for spring bottle
DSZH
DSZH
Dye cleaner 29028004
DSZH
DSZH
Tube cutter D.4X16 imperial 21004005
DSZH
DSZH
Torque wrench kit 1/4 3/8 1/2 TA771FC
DSZH
DSZH
Refrigerant bottle R290 370gr (including deposit)