We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

Image not available
DSZHHVAC Tools

DSZH Deluxe digital thermometer 7mm contact probe & telescopic air probe

DSZH TA410AX/BX is a digital thermometer for HVAC applications featuring a 7mm contact probe and telescopic air probe. Ideal for technicians requiring dual-measurement capability in heating, cooling, and ventilation…

SKU 3G-CBM-01575

Also listed as: COR 40170 · COR-40170

Brand
DSZH
Item
Deluxe digital thermometer 7mm contact probe & telescopic air probe
Category
HVAC Tools
UNSPSC
41112509 — Air velocity and temperature monitors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

DSZH
model
TA410AX/BX
air probe
telescopic
contact probe diameter
7mm

Datasheet Content

Digital Thermometer TA410AX/BX Instruction Manual Thank you for purchasing the TA410AX/BX Digital Thermometer. Please read this instruction manual carefully before use so that you can use the product properly. Safety Precautions Before operation, read this "Safety Precautions" section carefully to use the product properly. The precautions shown herein are divided into the two categories. Since both of them contain important safety precautions, make sure that you observe them. Warning Improper handling poses the risk of death or serious injury. Improper handling poses the risk of injury or damage to the product or Caution property. However, in some cases, this could result in serious damage. Symbols This symbol evokes your “Attention”. This symbol denotes “Don’ts”. This symbol denotes “Musts”. About the Main Unit Caution Do not use this product for improper purposes. Stop using the product as soon as you notice an anomaly Do not disassemble or modify this product. About the Battery Warning Never throw Never recharge the battery. Use the designated battery (006P 9V). Caution Observe the polarity (+/-) of the battery. Remove the battery when the battery has expired or if the unit is not to be used for a long period of time. The battery life will vary depending on operating temperatures. 1 1. Battery Installation * Turn off the unit when you replace the battery. (1) Use a coin to unscrew the battery cover. (2) Connect the battery cable to the battery and put it in the case. (3) Close the battery cover and firmly tighten the two screws. 2. Probe Installation and Extension Cord Connection (1) To install the probe, insert the probe into the unit as in the right figure. After installation, lightly pull the probe to check that it will not come off. (2) To remove the probe, pull out the probe while pushing the probe stopper. (3) To install the extension cord, like the probe, connect it to the unit as in the right figure. To remove it, like the probe, pull out the cord while pushing the probe stopper. The probe connection of the extension cord is also equipped with a probe stopper. 2 3. Operating Procedures and Features (1) Power ON/OFF Press the POWER key. After all the digits have flashed on the display for one second, the unit is ready for measurement. Press the POWER key again to turn the unit off. Press the POWER key to turn off the unit at any point of time during operation. Also, turned on, the unit is set in the normal measurement mode. * This instruction manual describes the situation where the unit has just been turned on (the situation where there is no feature indications on the left side of the display) as the normal measurement mode. (2) HOLD Features (See the chart on Page 4.) 1. HOLD Feature This feature holds the indication of the current measured temperature. "HOLD" flashes on the display. 2. Maximum Value HOLD Feature (MAX HOLD) "MAX" and "HOLD" flashing on the display means that the unit holds the indication of the constantly updated highest temperature. If an error occurs, the unit will hold the indication of the error. 3. Minimum Value HOLD Feature (MIN HOLD) "MIN" and "HOLD" flashing on the display means that the unit holds the indication of the constantly updated lowest temperature. If an error occurs, the unit will HOLD the indication of the error. 4. Average Value HOLD Feature (AVG HOLD) This feature indicates the average values between any two points of time. While "AVG" is flashing on the display, the unit retains the temperature data being measured. In so doing, the unit indicates the actual temperature data. Press the HOLD key to have "AVG" and "HOLD" flash on the display. The unit will hold the average value calculated based on the temperature data retained in it. The unit can average the data for up to 5 hours. If the unit is used for more than 5 hours, the feature will be canceled. If an error occurs during equation, the unit will hold the indication of the error. 3 4 4. Error Messages (1) Broken Detection Terminal Indication If the detection terminal of the probe gets broken or the probe is not connected, "Err" is indicated on the display as in the right figure. If so indicated, replace or connect the probe. (2) Over Range Indication If the temperature being measured goes beyond the measurable range, "or" or "-or" is indicated on the display. * This indication may appear when the detection terminal of the probe is almost broken. If it is clear that the temperature being measured is within the measurable range, check the probe. In addition, if the instrument reading abnormally fluctuates, check the probe. (3) Low Battery Indication If the battery voltage gets low, the low battery voltage indication will flash with 5 hours of life left. In addition, the whole display is programmed to blink with 30 minutes of life left. * The duration of the low battery voltage indication varies depending on the battery type and environment. (4) Troubleshooting If you have found a problem with the display or features, use a thin stick to press the reset button located on the battery compartment. Pressing the reset button will reset the unit to the same setting as it has just been turned ON. * If the unit will not operate properly even after pressing the reset button, the unit may have been damaged. In such a case, contact your authorized dealer. 5 5. How to Place the Probe Place the probe perpendicular to the contact surface or facing to the direction wind is coming from. In addition, note that the unit will not operate properly if the surface is rough or uneven. * Before measurement, check the measurable range of the probe. If you measure a temperature beyond the range, there is a risk of failure and/unexpected injury. 6. Maintenance (1) Storage When you store the unit, avoid such places as follows: * Place exposed to direct sunlight * Place that oscillates violently * Place where the humidity is high (above 80%R.H.) * Hot atmosphere (above 50°C) * High electromagnetic field (2) If the Housing Gets Dirty If the housing gets dirty, immerse a shop towel in water or oil to wipe the housing. The housing is made of ABS resin. Do not use organic solvents such as thinner, benzine and alcohol. These solvents may deform and/or discolor the housing and keyboard. 6 -MEMO- 7 -MEMO- 8 -MEMO- 9 Warranty Thank you very much for purchasing one of our products. This product has been manufactured through a perfect quality control and strict inspection process. However, should a failure occur despite proper use, we warrant the product for one year after the date of purchase. In addition, note that failures due to the following causes will not be warranted in any case. * Failures due to accidental force such as fires and earthquakes. * Failures due to improper use, inappropriate handling or modification. * Failures and damages not deemed to be our responsibilities. Product Name: TA410AX/BX Serial Number: Date of Purchase: Authorized Dealer: * This warranty is void without the serial number, date of purchase, and authorized dealer. Make sure to return this warranty together with the actual product. ICHINEN TASCO CO., LTD. 1-17-20 Inadauemachi, Higashi-Osaka City, Osaka 577-0002 JAPAN Phone: 81-6-6748-9310 Fax: 81-6-6748-9320 This warranty is exclusively for TA410AX/TA410BX. The accessories are not to be covered by this warranty. Authorized Dealer 10 1-17-20 Inadauemachi, Higashi-Osaka City, Osaka 577-0002 JAPAN Phone: 81-6-6748-9310 Fax: 81-6-6748-9320 Web Site: http://www.tascojapan.co.jp/ JY20130319TA410AX_1 3G-CBM-01575 - Thermomètre digital TA410AX/BX Manuel d’uƟlisaƟon Merci d’avoir acheté le thermomètre digital TA410AX/BX. Merci de lire ces instruc ons avec précau on afin d’u liser le produit correctement. Mesure de sécurité : Avant l’u lisa on, lisez les mesures de sécurité avec précau on pour u liser le produit correctement. A en on :  Ne pas u liser ce produit pour des u lisa ons non adaptées.  Arrêtez d’u liser le produit si vous remarquez quelconque anomalie.  Ne pas démonter ou modifier le produit À propos de la ba erie :  Ne pas jeter la ba erie  Ne pas recharger la ba erie  U liser la ba erie adaptée (006P 9V).  Observer la polarité (+/-) de la ba erie  Re rer la ba erie quand elle est déchargée ou si le produit n’est pas u lisé pendant une longue période.  La durée de vie de la ba erie dépendra des températures mesurées. 1. InstallaƟon de la baƩerie *Éteindre le produit quand vous remplacez la ba erie (1) U liser un tournevis cruciforme pour re rer le cache de la ba erie. (2) Connecter le câble à la ba erie (3) Refermer le couvercle et serrer fermement les deux vis 2. InstallaƟon de la sonde et connexion de la rallonge (1) Pour installer la sonde, insérez la dans l’unité comme sur le schéma à droite. Après l’installa on, rez légèrement sur la sonde pour vérifier qu’elle ne se re re pas. (2) Pour re rer la sonde, rez sur la sonde tout en appuyant sur le bouton d’éjec on de la sonde. (3) Pour installer la corde d’extension, comme pour la sonde, connectez là à l’unité comme sur le schéma à droite. Pour la re rer, effectuez la même manipula on que pour re rer la sonde. 3. Procédures d’uƟlisaƟon et foncƟonnalités (1) Allumage ON/OFF Appuyer sur le bouton POWER. Quand tous les numéros sont apparus pendant une seconde, l’unité est prête à être u lisé. Appuyer sur le bouton POWER de nouveau pour l’éteindre. Appuyer sur le bouton POWER, à n’importe quel moment de l’u lisa on pour l’éteindre. À l’allumage, l’unité est réglée en mode de mesure « normal ». *Ce manuel d’uƟlisaƟon décrit la situaƟon où l’unité a été juste allumé (la situaƟon où il n’y a pas de voyant indicateur de foncƟonnalité sur la parƟe gauche de l’écran) en mode normal. (2) FoncƟonnalités HOLD  Fonc onnalité HOLD Ce e fonc onnalité permet de maintenir affiché la température actuellement mesuré. La men on « HOLD » s’affiche à l’écran.  Fonc on de main en de la valeur maximale (MAX HOLD) Le clignotement des mots "MAX" et "HOLD" sur l'écran signifie que l'appareil conserve l'indica on de la température la plus élevée constamment mise à jour. En cas d'erreur, l'appareil conserve l'indica on de l'erreur.  Fonc on de main en de la valeur minimale (MIN HOLD) Le clignotement des mots "MIN" et "HOLD" sur l'écran signifie que l'appareil main ent l'indica on de la température la plus basse constamment mise à jour. En cas d'erreur, l'appareil main ent l'indica on de l'erreur.  Caractéris que de main en de la valeur moyenne (AVG HOLD) Ce e fonc on indique les valeurs moyennes entre deux points dans le temps. Pendant que "AVG" clignote à l'écran, l'appareil conserve les données de température mesurées. L'appareil indique ainsi les données de température actuelles. Appuyez sur la touche HOLD pour que "AVG" et "HOLD" clignotent sur l'écran. L'appareil conserve la valeur moyenne calculée sur la base des données de température enregistrées. L'appareil peut calculer la moyenne des données pendant 5 heures maximum. Si l'appareil est u lisé…
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

DSZH Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

DSZH TA410AX/BX is a digital thermometer for HVAC applications featuring a 7mm contact probe and telescopic air probe. Ideal for technicians requiring dual-measurement capability in heating, cooling, and ventilation system diagnostics.

Frequently Asked Questions

Where can I buy the DSZH TA410AX/BX digital thermometer?

3G Electric is an authorised distributor of DSZH instruments. We source and ship the TA410AX/BX thermometer worldwide with full logistics and customs support. Lead time on request.

What is the lead time for the DSZH TA410AX/BX thermometer?

Lead time varies based on current availability and your location. Contact 3G Electric for a specific delivery estimate. We handle all logistics and customs clearance for worldwide orders.

What are the probe specifications on the DSZH TA410AX/BX?

The thermometer features a 7mm contact probe for direct surface measurement and a telescopic air probe for ambient and airstream temperature readings. Both probes enable comprehensive HVAC system diagnostics.

Used in

Common applications for DSZH
Split-system air-conditioner service: DSZH manifold bases and SAE/NPT reducers integrate with technician gauge sets for pressure monitoring and refrigerant charge.
Rooftop packaged unit maintenance: Flare connector caps, hose tips, and union fittings expedite field replacement of damaged lines and adapters on commercial cooling systems.
Refrigerant recovery and recycling: DSZH bottle adapters (R600A-rated) connect recovery cylinders to hose lines, enabling safe extraction of flammable and standard refrigerants.
Process-cooling loop installation: SAE straight male/female unions and reducers support temporary or permanent manifold assembly on industrial water-chilled equipment.
Heat-pump seasonal service: DSZH dudgeon extensions and adapter kits allow technicians to connect diagnostic gauges to restricted or recessed access ports on reversing-valve manifolds.
Field emergency repairs: Individual DSZH fittings stocked in stock allow technicians to repair or modify hose connections on-site without returning to the shop for components.

DSZH Products

3G Electric supplies DSZH hvac tools. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Digital thermometer -50 +70°C 29005020
DSZH
Digital thermometer -50 +70°C 29005020
Surface thermometer 29005024
DSZH
Surface thermometer 29005024
Digital pocket thermometer -50+300°
DSZH
Digital pocket thermometer -50+300°
Rectangular thermometer 29005050
DSZH
Rectangular thermometer 29005050
D52 round thermometer 29005030
DSZH
D52 round thermometer 29005030
Thermometer flanged L1500 D100 29005044
DSZH
Thermometer flanged L1500 D100 29005044

More from DSZH

View all DSZH parts
Transfer bottle 12kg gray CBM DO NOT RECOVER FULL BOTTLES
DSZH
Transfer bottle 12kg gray CBM DO NOT RECOVER FULL BOTTLES
DSZH
DSZH
Refrigerant bottle R404 800 GR (including deposit)
DSZH
DSZH
Dehydrating liquid 28.3G Thawzone
DSZH
DSZH
Heat strip for spring bottle
DSZH
DSZH
Dye cleaner 29028004
DSZH
DSZH
Tube cutter D.4X16 imperial 21004005
DSZH
DSZH
Torque wrench kit 1/4 3/8 1/2 TA771FC
DSZH
DSZH
Refrigerant bottle R290 370gr (including deposit)