We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

DSZH 4V bypass kit flex hose R410 R32 R407 R134 - HVAC Tools
DSZHHVAC Tools

DSZH 4V bypass kit flex hose R410 R32 R407 R134

DSZH 4-way bypass kit flex hose assembly for HVAC refrigerant service across R410, R32, R407, and R134 systems. Features color-coded hoses: low pressure (blue), high pressure (red), and vacuum (yellow). Essential for…

SKU 3G-CBM-01400

Also listed as: COR 15068 · COR-15068

Brand
DSZH
Item
4V bypass kit flex hose R410 R32 R407 R134
Category
HVAC Tools
UNSPSC
41112509 — Air velocity and temperature monitors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

DSZH
type
4-way bypass kit
hose types
low pressure (blue), high pressure (red), vacuum (yellow)
refrigerants
R410, R32, R407, R134

Datasheet Content

Fiche technique kit bypass 4 voies 3G-CBM-01400 & COR15072 2 3 1 4 I. Raccordement 1. A) Connecter le flexible de basse pression (bleu) port 1. B) Assurez-vous que la vanne bleu est fermée. 2. A) Connecter le flexible de haute pression (rouge) port 4. B) Assurez-vous que la vanne rouge est fermée. 3. Connecter les flexibles bleu et rouge au système. 4. A) Connecter le flexible jaune pour le vide au port 3 [port tirage au vide]. B) Assurez-vous que la vanne jaune est fermée. 5. A) Connecter le flexible noir au port 2 [port recuperation]. B) Assurez-vous que la vanne noire est fermée. 2. La récupération du fluide frigorigène dans le système 1. Vérifier que l'intérieur du collecteur ne possède pas de liquide de refroidissement résiduel différent de ce que vous allez utiliser. 2. Connecter la station de récupération de gaz réfrigérant. 3. Raccorder l'installation comme indiqué au chapitre 1. 4. Ouvrer la vanne bleu si vous avez besoin de récupérer du côté basse pression. 5. Ouvrer la vanne rouge si vous avez besoin de récupérer du côté haute pression. 6. Ouvrer la vanne jaune. 7. Suivre les instructions du fabricant de la station de récupération pour effectuer la récupération de refrigerant. 3. Tirage au vide 1. Vérifier qu'il y n'aie pas pression restante dû à une utilisation précédente à l'intérieur du kit by-pass. 2. Connecter la pompe à vide comme indiqué dans le chapitre dédié à cette partie. 3. Raccorder l'installation comme indiqué au chapitre 1. 4. Ouvrir les vannes LOW et HIGH, en fonction de comment a été effectué le raccordement. 5. Ouvrir la vannes VAC. 6. Démarrer la pompe à vide et exécuter un cycle de vide d'au moins 30 minutes. 7. Vérifier la tenue de l'installation. 8. Fermer les vannes VAC, LOW et HIGH. 4. Charge de réfrigérant à l'intérieur de l'installation 1. Vérifier que l'intérieur du collecteur ne possède pas de liquide de refroidissement résiduel différent de ce que vous allez utiliser. 2. Raccorder bouteille de refrigerant. 3. Raccorder l'installation comme indiqué au chapitre 1. 4. Ouvrir la soupape LOW s'il est nécessaire de charger l'installation du côté de basse pression. 5. Ouvrir la soupape HIGH s'il est nécessaire de charger l'installation du côté de haute pression. 6. Réguler la quantité de fluide avec la soupape REF. 7. Une fois terminée, fermer les soupapes REF, LOW et HIGH. 5. Vérification de la pression de l'installation 1. Vérifier que l'intérieur du collecteur ne possède pas de liquide de refroidissement résiduel différent de ce que vous allez utiliser. 2. Raccorder l'installation comme indiqué au chapitre 1. 3. S'assurer que la vanne LOW soit fermée. 4. S'assurer que la vanne HIGH soit fermé. 5. Acheminer l'installation de conditionnement. 6. Vérifier que les pressions lues sur les manomètres de basse pression et haute pression correspondent aux valeurs indiquées par le constructeur de l'installation.

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

DSZH Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

DSZH 4-way bypass kit flex hose assembly for HVAC refrigerant service across R410, R32, R407, and R134 systems. Features color-coded hoses: low pressure (blue), high pressure (red), and vacuum (yellow). Essential for technician fieldwork and system diagnostics.

Frequently Asked Questions

Where can I buy the DSZH COR15068 4V bypass kit worldwide?

Order directly from 3G Electric, your authorized HVAC tools distributor. We handle worldwide delivery, customs clearance, and logistics to ensure reliable receipt of your bypass kit.

What is the lead time for the DSZH 4V bypass flex hose kit?

Lead time varies by destination and current demand. Contact 3G Electric with your location and quantity for an exact delivery timeline. Available to order globally.

Which refrigerants does the DSZH COR15068 4V bypass kit support?

The kit is compatible with R410, R32, R407, and R134 refrigerants. Color-coded hoses (blue low-pressure, red high-pressure, yellow vacuum) simplify technician setup across multi-refrigerant service operations.

Used in

Common applications for DSZH
Split-system air-conditioner service: DSZH manifold bases and SAE/NPT reducers integrate with technician gauge sets for pressure monitoring and refrigerant charge.
Rooftop packaged unit maintenance: Flare connector caps, hose tips, and union fittings expedite field replacement of damaged lines and adapters on commercial cooling systems.
Refrigerant recovery and recycling: DSZH bottle adapters (R600A-rated) connect recovery cylinders to hose lines, enabling safe extraction of flammable and standard refrigerants.
Process-cooling loop installation: SAE straight male/female unions and reducers support temporary or permanent manifold assembly on industrial water-chilled equipment.
Heat-pump seasonal service: DSZH dudgeon extensions and adapter kits allow technicians to connect diagnostic gauges to restricted or recessed access ports on reversing-valve manifolds.
Field emergency repairs: Individual DSZH fittings stocked in stock allow technicians to repair or modify hose connections on-site without returning to the shop for components.

DSZH Products

3G Electric supplies DSZH hvac tools. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
4V bypass kit flex hose R410 R32 R407 R134
DSZH
4V bypass kit flex hose R410 R32 R407 R134
Bypass kit 2V 3flex R410 R32 R407 R134
DSZH
Bypass kit 2V 3flex R410 R32 R407 R134
Digital by-pass 4V + flex hose
DSZH
Digital by-pass 4V + flex hose
Parker
Parker
Bypass kit 2V 3flex1500mm R410 R32 R407 R134
Digital by-pass 2V + flex hose
DSZH
Digital by-pass 2V + flex hose
Low pressure gauge for bypass 2 & 4 way
DSZH
Low pressure gauge for bypass 2 & 4 way

More from DSZH

View all DSZH parts
Transfer bottle 12kg gray CBM DO NOT RECOVER FULL BOTTLES
DSZH
Transfer bottle 12kg gray CBM DO NOT RECOVER FULL BOTTLES
DSZH
DSZH
Refrigerant bottle R404 800 GR (including deposit)
DSZH
DSZH
Dehydrating liquid 28.3G Thawzone
DSZH
DSZH
Heat strip for spring bottle
DSZH
DSZH
Dye cleaner 29028004
DSZH
DSZH
Tube cutter D.4X16 imperial 21004005
DSZH
DSZH
Torque wrench kit 1/4 3/8 1/2 TA771FC
DSZH
DSZH
Refrigerant bottle R290 370gr (including deposit)