We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

SIT Gas block Eletrosit 0810200 - Gas Controls
SITGas Controls

SIT Gas block Eletrosit 0810200

Sit Eletrosit 0810200 is a class D gas block for appliance fuel control, featuring Rp 3/4 connection and 5 mbar pressure drop. Flow rates range from 6.0 to 12.9 m³/h across three family ratings, suitable for…

SKU 3G-CBM-00361

Also listed as: BLO 05104 · BLO-05104

Brand
SIT
Item
Gas block Eletrosit 0810200
Category
Gas Controls
UNSPSC
40142201 — Gas regulators
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

SIT
class
D
connection
Rp 3/4
pressure drop
5 mbar
flow rate family i
11.2 to 12.9 m³/h
flow rate family ii
9.8 to 11.2 m³/h
flow rate family iii
6.0 to 6.9 m³/h

Datasheet Content

SIT Group 810 ELETTROSIT M U LT I F U N C T I O N A L G A S C O N T R O L PUSH-BUTTON CONTROL ALL ADJUSTMENTS ACCESSIBLE FROM ABOVE THERMOELECTRIC SAFETY DEVICE ON-OFF SOLENOID VALVE PIN 63AN7060/3 ELECTRICAL MULTIFUNCTIONAL CONTROL High-flow multifunctional control complete with: push- button control (off, pilot, on), thermoelectric safety device for protection against improper operation, main burner ignition enabling button, pressure regulator, on-off solenoid valve with gas flow on-off control. On request, a step ignition device can be fitted. 810 ELETTROSIT is suitable for use with gas heating appliances (boilers, hot air generators, etc.). MAIN FEATURES Ignition button (pilot position) . Main burner ignition enabling button (manual or automatic version). Shutdown button . Thermoelectric flame failure device with reset interlock. Near-silent automatic on-off solenoid valve. Pressure regulator. Adjuster for gas flow to the pilot burner. Step ignition device (optional). Inlet and pilot filters. Inlet and outlet pressure test points. Threaded gas inlet and outlet ready for flanged connection. DESCRIPTION 1 Ignition button (pilot position) 7 Pressure regulator override device 2 Main burner ignition enabling 8 Inlet pressure test point button 9 Outlet pressure test point 3 Shutdown button 10 On-off solenoid valve 4 Pressure regulator setting device 11 Thermocouple connections 5 Pilot gas flow adjusting screw 12 Pilot outlets 6 Step ignition device adjustment 13 Main gas inlet screw 14 Main gas outlet 15 Holes (M5) for fixing flanges 10 14 3 9 2 1 8 7 15 13 4 5 6 11 12 TECHNICAL DATA • Gas connections: Rp 1/2 ISO 7 (Rp 3/4 on request) • Installation position: any position POWER SUPPLY • Gas families: I, II and III Voltage (AC) Consumption (mA) • Maximum gas inlet 230 V 50 Hz 75 pressure: 50 mbar 24 V 50 Hz 650 • Outlet pressure setting range: 3...18 mbar (on request 15...30) • Working temperature range: 0...60 °C • Pressure regulator: Class C • Automatic solenoid valve: Class D Data refer to EN 126 DIMENSIONS 123 84 Rp 3/4 82 , ,, , ,, NO PR , ,, REG. ADJ 126 102 , ,, ADJ , ,, 30 I¡ STEP PILOT ADJ. 28,5 12 Pilot Ø 6 Rp 3/4 2,5 11/32" 87 47 18,5 134 FLOW RATE AS A FUNCTION OF PRESSURE DROP Q Q [m [m3/h, 3 d=0.6] /h d=0.6] Rp 3/4 G 10 Rp G 1/2 8 Rp 1/2 Rp 3/4 6 I Family (d = 0.45) Q = 11.2 m3/h Q = 12.9 m3/h Æp = 5 mbar II Family (d = 0.6) Q = 9.8 m3/h Q = 11.2 m3/h Æp = 5 mbar 4 III Family (d = 1.7) Q = 6.0 kg/h Q = 6.9 m3/h Æp = 5 mbar 2 0 1 2 3 4 5 DpDp[mbar] [mbar] OPERATION Pilot flame ignition Depress the button and ignite the pilot flame, fig. 1 keeping the button fully depressed for a few seconds (fig.1). In controls with enabling for electrical ignition, the pilot can be ignited automatically by depressing the button . Release the knob and check that the pilot flame stays lit. If it goes out, repeat the ignition operation. Main burner ignition Depress the transverse button (fig.2) (manual versions). The gas passage to the main burner is opened by fig. 2 powering the automatic solenoid valve. The valve with step ignition device reaches the maximum flow after about 10 seconds. Pilot flame ignition Fully depress the knob (fig.1) to keep the main burner closed and the pilot flame lit. Shutdown Fully depress the knob (fig.3). fig. 3 CAUTION: the restart interlock device prevents igni- tion of the appliance until the flame failure device has stopped gas flow. At the end of this period (after clo- sing the magnet unit) it is possible to carry out the re-ignition operation. INSTALLATION Main gas connection The connection is made using gas pipes with Rp 1/2 ISO 7 (or Rp 3/4) threading. Torque: 25 Nm. If, alternatively, flanges (available on request) are used, first screw the pipes onto the flanges and then the flanges to the control. Recommended torque for the flange fixing screws: 3 Nm. Connection to the pilot burner Pipes with a 4 mm, 6 mm or 1/4 diameter can be used. Use a nut and olive of appropriate dimensions. Tighten to 7 Nm torque. Electrical connections All the electrical connections should be made in compliance with the provisions of the electrical standards in force. Check that the voltage and frequency of the coils, indicated on the control, are correct. Check that all the connections, in particular the earth, are carried out to industry standards. The 24Vac versions must be powered by an isolating transformer (with very low safety voltage). Carry out the connections in accordance with the rules for the appliance. To access the supply and earth terminals, unscrew the screw and remove the cover. To access the electric ignition enabling terminals “W” (where applicable), unscrew the screw “M” and remove the enabling device. The limit thermostat “LS” should be inserted into the ther- moelectric circuit. CAUTION: after making the connections, check gas tightness and electrical insulation. 1 K 2 TA ON-OFF ~ 3 LS W w = Pilot burner electric ignition enabling WIRING PLANS K = Internal enabling for main burner ignition TA = Ambient thermostat LS = Limit thermostat SETTINGS AND ADJUSTMENTS Measurement of the inlet and outlet pressure The inlet and outlet pressures of the gas can be measured by unscrewing the provided test point sealing screws. Replace screws with 2.5 Nm torque. Gas flow-rate adjustment to the pilot Adjustment screw (PILOT ADJ.). Screw in the screw to reduce the flow, or unscrew it to increase flow. Outlet pressure adjustment Adjustment screw (REG. ADJ.). Remove the protective cap, screw in the adjustment screw (REG. ADJ.) to increase the outlet pressure, or unscrew it to decrease flow. Adjustment of the step ignition minimum flow with…

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

SIT Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Sit Eletrosit 0810200 is a class D gas block for appliance fuel control, featuring Rp 3/4 connection and 5 mbar pressure drop. Flow rates range from 6.0 to 12.9 m³/h across three family ratings, suitable for residential and commercial gas heating systems.

Frequently Asked Questions

Where can I buy the SIT Eletrosit 0810200 gas block worldwide?

Order the SIT Eletrosit 0810200 from 3G Electric. We source gas controls globally and handle all logistics, customs clearance, and delivery to your facility anywhere in the world. Lead time on request.

What are the flow rate ratings for the Eletrosit 0810200?

The SIT Eletrosit 0810200 supports three family ratings: Family I: 11.2–12.9 m³/h, Family II: 9.8–11.2 m³/h, Family III: 6.0–6.9 m³/h. All operate at 5 mbar pressure drop.

Is the SIT Eletrosit 0810200 suitable for residential heating systems?

Yes. The Eletrosit 0810200 Class D gas block is designed for both residential and commercial gas heating applications. The Rp 3/4 connection and three family flow ratings accommodate a range of appliance sizes and fuel control requirements.

Used in

Common applications for SIT
Commercial boiler gas-control replacement — Sigma 845 / 848 on hot-water and steam boilers
Catering and commercial kitchen equipment — Eurosit 630 thermostatic valves on fryers, ovens, and steamers
Residential heating appliance service — NOVA 820 / 822 / 824 as OEM-replacement gas-control valves
Standing-pilot gas appliance refurbishment — Eurosit 630 and Minisit thermostatic controls
Industrial gas-fired process equipment — Sigma 848 modulating gas valves for burner integration

SIT Products

3G Electric supplies SIT gas controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Gas block Eletrosit 0810158
SIT
Gas block Eletrosit 0810158
Eletrosit gas block 0810156
SIT
Eletrosit gas block 0810156
Eletrosit gas block 0810162
SIT
Eletrosit gas block 0810162
Eletrosit gas block 0810138
SIT
Eletrosit gas block 0810138
0810174 Eletrosit gas block
SIT
0810174 Eletrosit gas block
Gas block Eurosit 0630104
SIT
Gas block Eurosit 0630104

More from SIT

View all SIT parts
Pilot light 3 flames 0160005
SIT
Pilot light 3 flames 0160005
Pilot light 2 flames 0140024
SIT
Pilot light 2 flames 0140024
Pilot light 1 flame 0150073
SIT
Pilot light 1 flame 0150073
Pilot light 1 flame 0140039
SIT
Pilot light 1 flame 0140039
SIT
SIT
Connector with cable 830 0960107
SIT
SIT
Gas block Sigma 0848108
SIT
SIT
Minisit gas block 0710750
SIT
SIT
Intermediate contact M9 X 1