We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

Inpro Suction unit GPS10 - Oil Supply
InproOil Supply

Inpro Suction unit GPS10

The Inpro GPS10 is an oil supply suction unit delivering 8 l/h flow rate for domestic heating fuel systems. Operating at AC 230V 50Hz with 50 W power consumption, it features a 3.5 l reservoir and achieves 8 m…

SKU 3G-CBM-00105

Also listed as: ALI 05030 · ALI-05030

Brand
Inpro
Item
Suction unit GPS10
Category
Oil Supply
UNSPSC
40151524 — Oil pumps
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

Inpro
voltage
AC 230V 50Hz
fuel type
Fioul Domestique
pump type
Moto-pompe à piston
max flow rate
8 l/h
power consumption
50 W
return connection
3/8" F BSP
reservoir capacity
3.5 l
suction connection
3/8" F BSP
overflow connection
1/2" F BSP
max vertical distance
8 m
max horizontal distance
100 m

Datasheet Content

GPS 10 et GPS 10 MAXI MANUEL D’INSTALLATION V0824-101 2 INDEX 1. Spécifications techniques GPS 10………………………4 2. Installation GPS 10…………………………………………….5 3. Repérage des pannes et entretien ……………………6 4. Vue explosée GPS 10…………………………………………7 5. Codes des composants et pièces détachées………7 6. Accessoires - Système de détection des fuites…..8 7. Schéma de câblage GPS 10………………………………..9 8. Exemples d'installation…………………………………….10 9. Liste de référence rapide d'affichage ….……........11 3 1. Spécifications techniques GPS 10 TYPE DE POMPE Pompe solénoïde d’aspiration HAUTEUR D’ÉLÉVATION (MAX.) 8 m vertical (Diamètre intérieur Tube 8 mm) DISTANCE HORIZONTALE MAX. 100 m horizontal (Diamètre intérieur Tube 8 mm) DÉBIT À LA SORTIE 8 L/h à: 8 m vertical et 25 m horizontal (Diamètre intérieur Tube 8 mm) 15 l/h à: 5 m vertical et 25 m horizontal RACCORDEMENT ENTRÉE 3/8 " F BSP RACCORDEMENT SORTIE 3/8 " F BSP RACCORDEMENT SORTIE TROP-PLEIN ½ " F BSP ALIMENTATION ÉLECTRIQUE AC 230V, 50Hz CONSOMMATION D’ÉNERGIE 50 W GPS 10 GPS 10 MAXI CAPACITÉ TOTALE DU RÉSERVOIR 3,5 Litres. 12 Litres Largeur: (240 mm) (350 mm) DIMENSIONS: Profond: (130 mm) (225 mm) Hauteur: (335 mm) (345 mm) POIDS 3 kg 4 kg TYPE DE COMBUSTIBLE Mazout, fioul domestique (HVO) et carburant diesel GPS 10 GPS 10 MAXI 4 2. Installation GPS 10 Raccorder le conduit d’aspiration - sans clapet de retenue 3. - de la cuve principale Installation GPS 10au filtre (1) et le tuyau d’alimentation (par gravité) à la «sortie» de l’appareil (6). 1 Installer le bac de rétention et sa sonde de détection IR. -Toute pompe aspirante nécessite une conduite d'aspiration dédiée à partir du réservoir de fioul. -Si votre tuyau est en PVC ou en cuivre, vous devez utiliser un insert de tuyau de 10 mm -non fourni- à toute jonction équipée d'un raccord à compression. Brancher le GPS 10 à l’alimentation électrique soit à travers une fiche (non incluse) soit à travers une dérivation électrique à fusibles (voir schéma de 2 câblage p. 9). Le cordon doit passer à travers le passe fil à la partie arrière de la plaque de montage (cf. nº7 sur image page 7) Une fois sous tension, le voyant LED «niveau bas» s’allumera, ainsi que celui vert d’alimentation électrique. Pour démarrer le fonctionnement automatique du GPS, appuyez sur le bouton de 3 démarrage et maintenez-le enfoncé. La pompe se met en marche et remplit le réservoir du GPS 10 jusqu'à ce que le témoin de bas niveau s'éteigne. La pompe peut être bruyante au début, jusqu'à ce que le carburant commence à arriver à la pompe. Une fois le niveau bas atteint, vous pouvez relâcher le bouton de démarrage, car le GPS fonctionne en mode automatique. Mode de remplissage automatique - A lire avant d'installer l'appareil. - Mettre l'appareil sous tension (240 V) - Appuyer sur le bouton de démarrage et le maintenir enfoncé. - Le GPS affiche une séquence lumineuse. - La pompe commencera alors à fonctionner/aspirer. - Relâchez le bouton de démarrage lorsque les LED de niveau bas et d'alimentation clignotent alternativement. L'appareil est maintenant en mode automatique. - En mode automatique, les 2 LED inférieures clignotent par intermittence. (voir détails P11) 4 Lorsque le fioul a rempli le réservoir du GPS 10 jusqu'au niveau maximum programmé (80% environ), l'interrupteur de niveau de travail arrête la pompe. Le GPS est maintenant prêt à l'emploi et l’appareil peut être utilisé: La GPS 5 10 gère automatiquement l'alimentation en combustible. Lorsque, en mode automatique, le niveau de bruit et de vibration est élevé ou instable, cela peut indiquer qu’il y a de l’air qui entre à l’intérieur de la pompe: Vérifiez l’étanchéité de vide de l’aspiration, la dimension du tuyau et les distances relatives aux limites d’aspiration de votre GPS 10. (*) Le raccord de trop-plein est à double usage: 1) Il doit être raccordé à un tuyau de retour vers le réservoir comme dispositif de sécurité en cas de défaillance de l'interrupteur à flotteur. Un détecteur de fuites et un bac à fioul sont disponibles comme alternative s'il n'est pas possible de ramener le trop-plein dans le réservoir. Le fabricant décline toute responsabilité en cas de dommages causés par une installation ne comportant pas au moins l'une de ces deux options de sécurité supplémentaires. 2) Il peut être raccordé au réservoir de fioul pour permettre la ventilation du réservoir GPS s'il doit être scellé pour éviter les odeurs indésirables. 5 4. Repérage des pannes et entretien Si le fioul n’arrive pas au GPS 10: - Vérifiez si le tuyau d’aspiration est bloqué et/ou l’étanchéité du vide. - Est-ce que la hauteur d’élévation verticale est inférieure à 8 m? - Vérifier que le filtre n'est pas colmaté ou sale. Si le problème persiste encore: - Vérifiez l’alimentation électrique de la pompe (avec un manomètre à vide ou en plaçant votre main à l’entrée du filtre et en appuyant sur le bouton de mise en marche pour voir si vous pouvez noter l’aspiration). - Vérifiez la tension de l’alimentation électrique. - Amorcez avec huile moteur la conduite d’aspiration sur GPS 10. Démarrez alors la pompe pour faire passer cette huile ainsi que le fioul de la cuve. Mantenimiento - Vérifier s’il y a du fioul au réservoir principal. Après 1 heure de pompage • Limpiar periódicamente sans fioul, la pompe el filtro. s’arrête automatiquement. - Vérifier si le clapet de pied (de retenue) de la citerne est enlevé -pas Maintenance: nécessaire avec la GPS 10-. - Vérifier si voyant LED supérieur n’est pas allumé (un objet ou liquide a activé la détection de fioul sur le bac Entretien: - Nettoyer régulièrement le filtre et la crépine. Courbe d’aspiration: 6 5. Vue explosée GPS 10 6. Codes des composants et des pièces détachées COMPOSANTS Art. Nr. 1. FILTRE 3/8" BSP - RACCORDEMENT ENTRÉE 01110001004010 2. POMPE: (commander avec les clips de compression et le tuyau n° 12 et 01000000004660 13) 3. RACCORDEMENT DU TROP-PLEIN 1/2 " BSP - 4. SONDE DE NIVEAU GPS 10/MAXI - FONCTIONNEMENT/SECURITÉ . 23130000032010 5. RÉSERVOIR DE FIOUL (3 litres) ou (MAXI 12 litres) 00000000000010 6. RACCORDEMENT DE SORTIE 3/8 " BSP 01050000380167 7. PASSE FIL L'ALIMENTATION ÉLECTRIQUE - 8. FLOTTEUR DE REMPLACEMENT EN ACIER INOXYDABLE Ø45*55*15mm 00230004154135 9. CIRCUIT DE CONTRÔLE DU GPS COMPLET (Ver. 101) (pompes > 2014) 23110000000810 10. SONDE INFRAROUGES POUR GPS 10, 50 cm de long 23080000005010 11. BAC DE RETENTION 23090000001000 12. TUYAUX TRANSPARENTS 01120000090805 13. 1 CLIP COMPRESSION 7.8/9.5 05080000000208 14. CONNECTEUR TERRE - 7 7. Accessoires - Système de détection des fuites Bac à fioul avec système de détection de fuites Le bac de rétention fourni avec le GPS 10 est équipé d’un système de détection de fuite infrarouge. Comment fonctionne le système de détection de fuites? Une fois installé, le fonctionnement de votre GPS reste inchangé, sauf si un liquide au niveau de la sonde infrarouge déclenche l'alarme de fuite ou si la sonde est endommagée. Alors qu'une fuite active le capteur, le capteur est défectueux ou la sonde de détection est manquante: - La pompe s'arrête (lors du pompage ou lorsqu'il est nécessaire de pomper) - Le voyant rouge supérieur "niveau élevé" s'allume. Cet état sera maintenu jusqu'à ce que la sonde infrarouge soit complètement propre et sèche ou remplacée. - Une fois la sonde nettoyée ou remplacée, le système se remplit à nouveau automatiquement, sauf si l'alarme de niveau bas ou de niveau haut a été activée. Installation du système de détection de fuite: 1.- Placer et fixer le bac de rétention horizontalement sous l'appareil. La distance entre le fond de l'appareil et le bac ne doit pas dépasser 25 cm. 2.- Placez le capteur infrarouge dans le clip bleu du bac à fioul, dans la position la plus basse possible. 3.- Extraire le bouchon jaune de la sortie du trop-plein. 4.- Vérifiez que le voyant LED supérieur s’allume quand un obstacle est détecté par la sonde infrarouge, et que la pompe s’éteint. 8 8. Schéma de câblage GPS 10 : Utilisez le passe fil du câble pour passer le câble d’alimentation au secteur 9 9. Exemples d'installation GPS 10 GPS 10 BRÛLEUR 10 BRÛLEUR Raccord de trop-plein 10 BAC Conduite d'aspiration BAC Important: Toute pompe aspirante de fioul nécessite une conduite d'aspiration spécifique à partir du réservoir de stockage de combustible, afin d'éviter que d'autres appareils ne prennent pas de combustible sur la même conduite d'aspiration. Pour installation extérieure, prévoir une armoire étanche pour le GPS 10. Ne pas installer en-dessous du niveau haut du fioul au réservoir principal, du fait qu’un siphon pourrait…
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Inpro Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The Inpro GPS10 is an oil supply suction unit delivering 8 l/h flow rate for domestic heating fuel systems. Operating at AC 230V 50Hz with 50 W power consumption, it features a 3.5 l reservoir and achieves 8 m maximum vertical suction distance. Ideal for residential and light commercial oil heating applications.

Frequently Asked Questions

Where can I source the Inpro GPS10 suction unit worldwide?

3G Electric is an authorised distributor of Inpro heating oil pumps. We handle worldwide logistics, customs clearance, and delivery. Contact us with your quantity and lead-time requirements.

What is the lead time and delivery timeline for the GPS10?

Lead time depends on current stock and your location. 3G Electric arranges expedited or standard shipping worldwide. Request a quote with your delivery address for exact timescale.

Can the Inpro GPS10 handle a 12 metre suction lift?

No. The GPS10 is rated for a maximum vertical suction distance of 8 m. For longer lifts, consult our technical team for alternative Inpro suction unit models.

Used in

Common applications for Inpro
Industrial heating systems — Inpro VD2 LR-2.2 low-pressure burner fuel unit with integral regulation for oil-fired boiler and furnace ignition control
Centralised oil-supply networks — Inpro MR-5U self-priming gear pump and TANKALERT SMS ultrasonic tank alarm for distributed lubrication and fuel-transfer operations
Burner fuel circuits — Inpro Series 202 diesel filter with 100–44 µm cartridge for pre-filtration of heavy fuel oil upstream of burner nozzles
Emergency gas-supply shutdown — Inpro hammer-and-chain tool and cabinet window for rapid access to gas regulation cabinets (GAZ70009, GAZ70011) in plant emergencies
Industrial pump stations — Inpro VDU5L23 suction-line pump with 150 µm strainer and 2 bar return-line rating for large-tank fuel-supply systems
Remote tank monitoring — Inpro TANKALERT SMS IP67 ultrasonic sensor with GSM/GPRS connectivity for automated oil-tank level reporting across distributed facilities

Inpro Products

3G Electric supplies Inpro oil supply. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Suction group GPS10 maxi
Inpro
Suction group GPS10 maxi
Suction group GPS35NWT
Inpro
Suction group GPS35NWT
Grundfos
Grundfos
Suction unit GPS130NW
Inpro
Inpro
Oil transfer unit VD2
Inpro
Inpro
Fuel transfer unit MR-10U
Inpro
Inpro
Oil transfer unit MR-3U

More from Inpro

View all Inpro parts
Fuel filter with safety 1/2"
Inpro
Fuel filter with safety 1/2"
Inpro
Inpro
Sieve filter D3/4 300µ
Inpro
Inpro
Fuel transfer unit MR-5U
Inpro
Inpro
VD2 LR-2.2 low pressure pump
Inpro
Inpro
Oil counter VZO4 with pulse output
Inpro
Inpro
Oil transfer unit VD5
Inpro
Inpro
PKM 60 fuel transfer unit
Inpro
Inpro
Pressure unit DWA60