We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

CANARM Belt-Drive Filtered Supply Fan, 3,300 cfm, 1/2 in wc, 2 hp, 208-230V AC - Belt-Drive Filtered Supply Fans with Drive
CANARMBelt-Drive Filtered Supply Fans with Drive

CANARM Belt-Drive Filtered Supply Fan, 3,300 cfm, 1/2 in wc, 2 hp, 208-230V AC

The CANARM Centrifugal Roof Supply Fan with a 12 7/8 in wheel is a belt-drive filtered supply fan. It delivers 3,300 cfm at 1/2 in wc maximum static pressure, powered by a 2 hp, single-speed, open dripproof motor…

SKU 3G-OTH-79107

Brand
CANARM
Item
Belt-Drive Filtered Supply Fan, 3,300 cfm, 1/2 in wc, 2 hp, 208-230V AC
Category
Belt-Drive Filtered Supply Fans with Drive
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

CANARM
Manufacturer Part Number
SIG12DD100EC
Type
3,300 cfm, 1/2 in wc Max., ODP, 2 hp
AC
208 to 230V
Number of Speeds
1
Nameplate Voltage
208 to 230V AC
Motor Enclosure Design Broad
Open Dripproof Motor

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

CANARM Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The CANARM Centrifugal Roof Supply Fan with a 12 7/8 in wheel is a belt-drive filtered supply fan. It delivers 3,300 cfm at 1/2 in wc maximum static pressure, powered by a 2 hp, single-speed, open dripproof motor rated for 208 to 230V AC (MPN SIG12DD100EC).

Frequently Asked Questions

What is the CANARM SIG12DD100EC centrifugal roof supply fan used for?

The CANARM SIG12DD100EC is a belt-drive filtered supply fan designed for rooftop ventilation in commercial or industrial buildings. It delivers 3,300 cfm of filtered outdoor air to maintain positive pressure and improve indoor air quality, commonly used in warehouses, factories, and HVAC systems.

What are the specifications of the CANARM SIG12DD100EC fan?

The CANARM SIG12DD100EC features a 12 7/8 in wheel, 3,300 cfm airflow, and 1/2 in wc maximum static pressure. It has a 2 hp, single-speed, open dripproof motor rated for 208 to 230V AC. The motor enclosure is open dripproof (ODP), and the unit is belt-driven with a filtered intake.

Where to buy the CANARM SIG12DD100EC fan worldwide?

3G Electric supplies the CANARM SIG12DD100EC centrifugal roof supply fan worldwide. As a global industrial equipment distributor since 1990, we handle full logistics, customs clearance, and delivery to your site. Contact us for availability and lead time on this belt-drive filtered supply fan.

How to install a CANARM belt-drive filtered supply fan?

Install the CANARM SIG12DD100EC on a level roof curb with proper sealing to prevent leaks. Ensure electrical supply matches 208 to 230V AC and the motor is wired per the diagram. Secure the belt drive tension per manufacturer guidelines, and verify the filter is clean before startup. Consult a licensed electrician.

Used in

Common applications for CANARM
Warehouse ventilation — CANARM direct-drive panel exhaust fans (e.g., P24-1RS9M115) for removing heat and fumes
Manufacturing plant air circulation — CANARM belt-drive blowers (e.g., BI2731000M) for high-volume air movement
Commercial kitchen exhaust — CANARM downblast exhausters (e.g., ALX165-DD033EC) for roof-mounted ventilation
Industrial floor cooling — CANARM mobile circulating fans (e.g., HVR36) for spot cooling in workshops
Office or retail space ventilation — CANARM wall-mount oscillating fans (e.g., CA30OSC-C) for general air circulation
Equipment cooling — CANARM ceiling-mount fans (e.g., HAF18-ZO) for targeted airflow over machinery

CANARM Products

3G Electric supplies CANARM belt-drive filtered supply fans with drive. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Belt-drive filtered supply fan with a 12 7/8 in wheel, delivering 2,600 cfm at 1/2 in wc maximum static pressure. Powered by a 2 hp, 208 to 230V AC, single-speed open dripproof motor. Suitable for rooftop ventilation in commercial or industrial buildings to supply filtered outdoor air
CANARM
Belt-drive filtered supply fan with a 12 7/8 in wheel, delivering 2,600 cfm at 1/2 in wc maximum static pressure. Powered by a 2 hp, 208 to 230V AC, single-speed open dripproof motor. Suitable for rooftop ventilation in commercial or industrial buildings to supply filtered outdoor air
Belt-drive filtered supply fan for roof-mounted ventilation. Delivers 2500 cfm at up to 1/2 in wc static pressure. Features a 1-1/2 hp, single-phase, open dripproof motor with variable speed, 208-230V AC. Suitable for introducing filtered supply air in commercial or industrial spaces
CANARM
Belt-drive filtered supply fan for roof-mounted ventilation. Delivers 2500 cfm at up to 1/2 in wc static pressure. Features a 1-1/2 hp, single-phase, open dripproof motor with variable speed, 208-230V AC. Suitable for introducing filtered supply air in commercial or industrial spaces
Centrifugal Roof Supply Fan: 12 7/8 in Wheel, 2,600 cfm, 1/2 in wc Max., ODP, 2 hp, 208 to 230V AC (MPN SIS12DD050EC)
CANARM
Centrifugal Roof Supply Fan: 12 7/8 in Wheel, 2,600 cfm, 1/2 in wc Max., ODP, 2 hp, 208 to 230V AC (MPN SIS12DD050EC)
Centrifugal Roof Supply Fan: 10 1/4 in Wheel, 1,975 cfm, 1/2 in wc Max., ODP, 1 hp, 1 Ph, Roof (MPN SIG9DD100EC)
CANARM
Centrifugal Roof Supply Fan: 10 1/4 in Wheel, 1,975 cfm, 1/2 in wc Max., ODP, 1 hp, 1 Ph, Roof (MPN SIG9DD100EC)
Roof-mount belt-drive filtered supply fan with 11 9/16 in wheel, delivering 2,500 cfm at 1/2 in wc maximum static pressure. Powered by a 1 1/2 hp, single-phase, open dripproof motor rated 208 to 230V AC, single speed. Used in commercial and industrial ventilation systems to supply filtered outdoor air
CANARM
Roof-mount belt-drive filtered supply fan with 11 9/16 in wheel, delivering 2,500 cfm at 1/2 in wc maximum static pressure. Powered by a 1 1/2 hp, single-phase, open dripproof motor rated 208 to 230V AC, single speed. Used in commercial and industrial ventilation systems to supply filtered outdoor air
Belt-drive filtered supply fan for roof mounting. Delivers 1,600 cfm at 1/2 in wc maximum static pressure. Includes a 1/2 hp, single-phase, open dripproof motor rated for 115/208-230V AC. Suitable for commercial and industrial ventilation applications requiring filtered supply air
CANARM
Belt-drive filtered supply fan for roof mounting. Delivers 1,600 cfm at 1/2 in wc maximum static pressure. Includes a 1/2 hp, single-phase, open dripproof motor rated for 115/208-230V AC. Suitable for commercial and industrial ventilation applications requiring filtered supply air

More from CANARM

View all CANARM parts
Roof-mount belt-drive filtered supply fan with 11 9/16 in wheel. Delivers 2,050 cfm at up to 1/2 in wc static pressure. Powered by a 1 1/2 hp, single-phase, open dripproof motor, 208 to 230V AC, single speed. Suitable for commercial or industrial ventilation systems requiring fresh filtered air
CANARM
Roof-mount belt-drive filtered supply fan with 11 9/16 in wheel. Delivers 2,050 cfm at up to 1/2 in wc static pressure. Powered by a 1 1/2 hp, single-phase, open dripproof motor, 208 to 230V AC, single speed. Suitable for commercial or industrial ventilation systems requiring fresh filtered air
Belt-drive filtered supply fan with 10 1/4 in wheel, delivering 1,975 cfm at 1/2 in wc maximum static pressure. Powered by a 1 hp, single-speed, open dripproof motor rated for 115/208-230V AC. Suitable for rooftop ventilation applications requiring filtered outdoor air intake
CANARM
Belt-drive filtered supply fan with 10 1/4 in wheel, delivering 1,975 cfm at 1/2 in wc maximum static pressure. Powered by a 1 hp, single-speed, open dripproof motor rated for 115/208-230V AC. Suitable for rooftop ventilation applications requiring filtered outdoor air intake
Belt-drive filtered supply fan delivering 2,850 cfm at up to 1 1/4 in wc static pressure. Powered by a 1 1/2 hp, single-phase, totally enclosed motor with nameplate voltage 115/208-230V AC and one speed. Suitable for rooftop fresh air intake in commercial and industrial ventilation systems
CANARM
Belt-drive filtered supply fan delivering 2,850 cfm at up to 1 1/4 in wc static pressure. Powered by a 1 1/2 hp, single-phase, totally enclosed motor with nameplate voltage 115/208-230V AC and one speed. Suitable for rooftop fresh air intake in commercial and industrial ventilation systems
Belt-drive filtered supply fan with 12 7/8 in wheel, delivering 3300 cfm at 1/2 in wc maximum static pressure. Powered by a 1 hp, single-speed, open dripproof motor rated for 208 to 230V AC. Suitable for industrial ventilation applications requiring tempered make-up air
CANARM
Belt-drive filtered supply fan with 12 7/8 in wheel, delivering 3300 cfm at 1/2 in wc maximum static pressure. Powered by a 1 hp, single-speed, open dripproof motor rated for 208 to 230V AC. Suitable for industrial ventilation applications requiring tempered make-up air
Belt-drive filtered supply fan for roof-mount applications. Delivers 4000 cfm at 1 in wc maximum static pressure. Powered by a 2 hp, 230/460V AC, three-phase, totally enclosed fan-cooled motor with single speed. Suitable for commercial or industrial ventilation systems requiring positive pressure and filtration
CANARM
Belt-drive filtered supply fan for roof-mount applications. Delivers 4000 cfm at 1 in wc maximum static pressure. Powered by a 2 hp, 230/460V AC, three-phase, totally enclosed fan-cooled motor with single speed. Suitable for commercial or industrial ventilation systems requiring positive pressure and filtration
Belt-drive filtered supply fan for roof-mount ventilation. Delivers 1,600 cfm at 1/2 in wc maximum static pressure. Powered by a 1/2 hp, single-phase, open dripproof motor with nameplate voltage 115/208-230V AC and single speed. Suitable for fresh air intake and general supply air applications
CANARM
Belt-drive filtered supply fan for roof-mount ventilation. Delivers 1,600 cfm at 1/2 in wc maximum static pressure. Powered by a 1/2 hp, single-phase, open dripproof motor with nameplate voltage 115/208-230V AC and single speed. Suitable for fresh air intake and general supply air applications
Belt-drive filtered supply fan with a 10 1/4 in wheel, delivering 2,450 cfm at 1 1/4 in wc maximum static pressure. Powered by a 1 1/2 hp, 3-phase, single-speed TEFC motor rated for 230/460V AC. Used in commercial and industrial ventilation systems to supply filtered air through ductwork
CANARM
Belt-drive filtered supply fan with a 10 1/4 in wheel, delivering 2,450 cfm at 1 1/4 in wc maximum static pressure. Powered by a 1 1/2 hp, 3-phase, single-speed TEFC motor rated for 230/460V AC. Used in commercial and industrial ventilation systems to supply filtered air through ductwork
Belt-drive filtered supply fan for roof-mount applications. Delivers 2,500 cfm at 1/2 in wc maximum static pressure. Powered by a 1 1/2 hp, 1-phase, open dripproof motor with variable speed capability, 208 to 230V AC. Suitable for commercial or industrial ventilation systems requiring filtered air intake
CANARM
Belt-drive filtered supply fan for roof-mount applications. Delivers 2,500 cfm at 1/2 in wc maximum static pressure. Powered by a 1 1/2 hp, 1-phase, open dripproof motor with variable speed capability, 208 to 230V AC. Suitable for commercial or industrial ventilation systems requiring filtered air intake