We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

3G Electric
CANARM P18-4 Hazardous Location Direct-Drive Panel Exhaust Fan - Hazardous Location Direct-Drive Panel Exhaust Fans
CANARMHazardous Location Direct-Drive Panel Exhaust Fans

CANARM P18-4 Hazardous Location Direct-Drive Panel Exhaust Fan

The CANARM P18-4 is a panel mounted hazardous location exhaust fan with a direct-drive, 18-inch blade, 1/3 hp motor delivering 3,200 cfm. It features a powder-coated steel frame, explosion-proof motor with Class B…

SKU 3G-OTH-80292

Also listed as: P184 · P18 4

Brand
CANARM
Item
P18-4 Hazardous Location Direct-Drive Panel Exhaust Fan
Part Number
P18-4
Category
Hazardous Location Direct-Drive Panel Exhaust Fans
Available to Order
Also known as:P18-4CANARM
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

CANARM
Manufacturer Part Number
P18-4
Type
1/3 hp, 3,200 cfm, 1 ph
Blade
18 in
Guard Type
Intake
Motor Type
Explosion Proof
Frame Finish
Powder Coated
Frame Material
Steel
Motor Enclosure
Totally Enclosed Air Over
Enclosure Design
Totally Enclosed Motor
Motor Insulation
Class B
Number of Speeds
1
Nameplate Voltage
115/208-230V AC
Guard Type Subheads
With Intake Guards
Method of Construction
Stamped
Hazardous Location Class
Class I, Div 1, Group C and D

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

CANARM Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The CANARM P18-4 is a panel mounted hazardous location exhaust fan with a direct-drive, 18-inch blade, 1/3 hp motor delivering 3,200 cfm. It features a powder-coated steel frame, explosion-proof motor with Class B insulation, and is rated for 115/208-230V AC single-phase operation. This assembled unit is suitable for Class I, Div 1, Groups C and D, and Class II, Div 1, Groups F and G hazardous locations, and includes intake guards.

Frequently Asked Questions

What is the CANARM P18-4 panel mounted hazardous location exhaust fan used for?

The CANARM P18-4 is used for ventilating hazardous environments such as chemical plants, grain elevators, and paint spray booths where flammable gases or combustible dusts are present. Its explosion-proof motor and Class I/II Division 1 ratings ensure safe operation in these areas.

What are the specifications of the CANARM P18-4 exhaust fan?

The CANARM P18-4 features an 18-inch blade, 1/3 hp motor delivering 3,200 cfm, and operates on 115/208-230V AC single-phase. It has a powder-coated steel frame, Class B insulation, and is rated for Class I, Div 1, Groups C and D, and Class II, Div 1, Groups F and G hazardous locations.

Where to buy the CANARM P18-4 hazardous location exhaust fan worldwide?

3G Electric supplies the CANARM P18-4 to customers worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your site. Contact us for pricing and lead time on this explosion-proof exhaust fan.

How to install the CANARM P18-4 panel mounted exhaust fan?

Install the CANARM P18-4 by mounting it securely to a panel or wall opening, ensuring the intake guard faces the hazardous area. Connect the single-phase motor to the correct voltage (115 or 208-230V AC) per local electrical codes. Always verify the area classification matches the fan's Class I/II ratings before operation.

Used in

Common applications for CANARM
Warehouse ventilation — CANARM direct-drive panel exhaust fans (e.g., P24-1RS9M115) for removing heat and fumes
Manufacturing plant air circulation — CANARM belt-drive blowers (e.g., BI2731000M) for high-volume air movement
Commercial kitchen exhaust — CANARM downblast exhausters (e.g., ALX165-DD033EC) for roof-mounted ventilation
Industrial floor cooling — CANARM mobile circulating fans (e.g., HVR36) for spot cooling in workshops
Office or retail space ventilation — CANARM wall-mount oscillating fans (e.g., CA30OSC-C) for general air circulation
Equipment cooling — CANARM ceiling-mount fans (e.g., HAF18-ZO) for targeted airflow over machinery
Not sure this is the right part? Photo-identify it

CANARM Products

3G Electric supplies CANARM hazardous location direct-drive panel exhaust fans. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

More from CANARM

View all CANARM parts

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first