We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

BUSSMANN FRS-R-35ID Class RK5 Time-Delay Indicating Fuse - Time-Delay Cylindrical Fuses
BUSSMANNTime-Delay Cylindrical Fuses

BUSSMANN FRS-R-35ID Class RK5 Time-Delay Indicating Fuse

The BUSSMANN FRS-R-35ID is a Class RK5, time-delay cylindrical fuse from the FRS-R-ID Series, rated 35 A at 600 V AC and 250 V DC with an indicating feature. 3G Electric interprets this demand and sources the exact…

SKU 3G-OTH-28585

Also listed as: FRSR35ID · FRS R 35ID

Brand
BUSSMANN
Item
FRS-R-35ID Class RK5 Time-Delay Indicating Fuse
Category
Time-Delay Cylindrical Fuses
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

BUSSMANN
Manufacturer Part Number
FRS-R-35ID
Series
FRS-R-ID
Type
FRS-R-ID Series, Time-Delay, 35 A, Indicating
AC
600 V
DC
250 V

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

BUSSMANN Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The BUSSMANN FRS-R-35ID is a Class RK5, time-delay cylindrical fuse from the FRS-R-ID Series, rated 35 A at 600 V AC and 250 V DC with an indicating feature. 3G Electric interprets this demand and sources the exact OEM part, supporting your facility with genuine industrial electrical components across 14 departments — and far more — while our specialist depth in controls ensures the right answer for your application.

Frequently Asked Questions

What is the BUSSMANN FRS-R-35ID fuse used for?

The BUSSMANN FRS-R-35ID is a Class RK5 time-delay indicating fuse rated 35 A, 600 V AC / 250 V DC. It protects motor circuits, transformers, and other inductive loads where temporary inrush currents occur, while its visual indicator shows when the fuse has opened for faster troubleshooting.

What are the specifications of the BUSSMANN FRS-R-35ID fuse?

The BUSSMANN FRS-R-35ID is a Class RK5 time-delay indicating fuse from the FRS-R-ID series. It is rated 35 A, 600 V AC and 250 V DC. The manufacturer part number is FRS-R-35ID. It provides overload and short-circuit protection with a visual open-fuse indicator.

Where to buy the BUSSMANN FRS-R-35ID fuse worldwide?

3G Electric supplies the BUSSMANN FRS-R-35ID fuse to customers worldwide. As a global industrial sourcing partner, we handle full logistics, customs clearance, and delivery to your site. Contact us for pricing and lead time on this Class RK5 time-delay indicating fuse.

How to select the right BUSSMANN FRS-R-ID series fuse for a motor circuit?

To select the correct BUSSMANN FRS-R-ID series fuse, match the continuous load current to the fuse amp rating (e.g., 35 A for a 35 A motor FLA). Ensure the voltage rating (600 V AC / 250 V DC) exceeds system voltage. The time-delay characteristic handles motor starting inrush without nuisance opening.

Used in

Common applications for BUSSMANN
Industrial motor control centers — BUSSMANN LPT series Class T time-delay fuses for branch circuit protection
Semiconductor protection in variable frequency drives — BUSSMANN FWA series fast-acting bolt-on fuses rated 150 V AC/DC
Automotive auxiliary circuit protection — BUSSMANN CB222 series Type II circuit breakers in 12 V DC systems
Control panel overcurrent protection — BUSSMANN FNA series midget time-delay indicating fuses for instrumentation
Main feeder protection in power distribution — BUSSMANN KLU series Class L time-delay bolt-on fuses up to 650 A
Fuse replacement in existing panels — BUSSMANN S-8301-1-R fuse block accepting 3AG and other glass/ceramic fuses

BUSSMANN Products

3G Electric supplies BUSSMANN time-delay cylindrical fuses. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Class RK5 time-delay cylindrical fuse rated 45 A, 600 V AC, and 250 V DC. Part of the FRS-R-ID series with an indicating feature that provides visual indication when the fuse opens. Designed for overcurrent protection in circuits with inductive loads such as motors and transformers, accommodating temporary inrush currents
BUSSMANN
Class RK5 time-delay cylindrical fuse rated 45 A, 600 V AC, and 250 V DC. Part of the FRS-R-ID series with an indicating feature that provides visual indication when the fuse opens. Designed for overcurrent protection in circuits with inductive loads such as motors and transformers, accommodating temporary inrush currents
Class RK5 time-delay cylindrical fuse rated 20 A, 600 V AC and 300 V DC. Features an integral blown-fuse indicator for visual confirmation of operation. Suitable for protecting motor circuits, transformers, and other inductive loads where temporary inrush currents occur
BUSSMANN
Class RK5 time-delay cylindrical fuse rated 20 A, 600 V AC and 300 V DC. Features an integral blown-fuse indicator for visual confirmation of operation. Suitable for protecting motor circuits, transformers, and other inductive loads where temporary inrush currents occur
Class RK5 time-delay cylindrical fuse rated 25 A, 600 V AC and 300 V DC, with an indicating feature for visual blown-fuse indication. Suitable for overcurrent protection in motor circuits, lighting panels, and distribution equipment
BUSSMANN
Class RK5 time-delay cylindrical fuse rated 25 A, 600 V AC and 300 V DC, with an indicating feature for visual blown-fuse indication. Suitable for overcurrent protection in motor circuits, lighting panels, and distribution equipment
Class RK5 time-delay cylindrical fuse rated 10 A, 600 V AC and 300 V DC. Features an indicating function that visually signals when the fuse has opened. Suitable for overcurrent protection in industrial circuits, including motor starters and control panels, where time-delay accommodates inrush currents
BUSSMANN
Class RK5 time-delay cylindrical fuse rated 10 A, 600 V AC and 300 V DC. Features an indicating function that visually signals when the fuse has opened. Suitable for overcurrent protection in industrial circuits, including motor starters and control panels, where time-delay accommodates inrush currents
Class RK5 time-delay cylindrical fuse rated 15 A, 600 V AC, and 300 V DC. Features an indicating function for visual blown-fuse detection. Suitable for overcurrent protection in branch circuits, motor, and transformer applications
BUSSMANN
Class RK5 time-delay cylindrical fuse rated 15 A, 600 V AC, and 300 V DC. Features an indicating function for visual blown-fuse detection. Suitable for overcurrent protection in branch circuits, motor, and transformer applications
Class RK5 time-delay cylindrical fuse rated 50 A, 600 V AC, and 250 V DC. Features a visual indicator that confirms operation, aiding maintenance and troubleshooting. Suitable for overload and short-circuit protection in branch circuits, such as motor and transformer applications in industrial power distribution
BUSSMANN
Class RK5 time-delay cylindrical fuse rated 50 A, 600 V AC, and 250 V DC. Features a visual indicator that confirms operation, aiding maintenance and troubleshooting. Suitable for overload and short-circuit protection in branch circuits, such as motor and transformer applications in industrial power distribution

More from BUSSMANN

View all BUSSMANN parts
Class RK5 time-delay fuse rated 45 A, 250 V AC and 125 V DC. The indicating feature provides visual confirmation when the fuse opens. Suitable for motor circuits, transformers, and lighting panels where temporary inrush currents occur
BUSSMANN
Class RK5 time-delay fuse rated 45 A, 250 V AC and 125 V DC. The indicating feature provides visual confirmation when the fuse opens. Suitable for motor circuits, transformers, and lighting panels where temporary inrush currents occur
Time-delay cylindrical fuse rated 30 A at 250 V AC. Midget size (13/32 in x 1 1/2 in), non-indicating. Provides overcurrent protection in circuits with motors, transformers, or other loads that draw temporary inrush currents
BUSSMANN
Time-delay cylindrical fuse rated 30 A at 250 V AC. Midget size (13/32 in x 1 1/2 in), non-indicating. Provides overcurrent protection in circuits with motors, transformers, or other loads that draw temporary inrush currents
Time-delay cylindrical fuse rated 125 mA at 500 V AC. Midget size (13/32 in x 1 1/2 in), non-indicating. Provides overcurrent protection with time-delay characteristic to withstand inrush currents in control circuits, motor starters, and panel boards
BUSSMANN
Time-delay cylindrical fuse rated 125 mA at 500 V AC. Midget size (13/32 in x 1 1/2 in), non-indicating. Provides overcurrent protection with time-delay characteristic to withstand inrush currents in control circuits, motor starters, and panel boards
Class RK5 time-delay cylindrical fuse rated 30 A at 250 V AC or 125 V DC. The indicating feature provides visual confirmation when the fuse has opened, aiding in troubleshooting. Suitable for overcurrent protection in motor circuits, lighting, and industrial equipment
BUSSMANN
Class RK5 time-delay cylindrical fuse rated 30 A at 250 V AC or 125 V DC. The indicating feature provides visual confirmation when the fuse has opened, aiding in troubleshooting. Suitable for overcurrent protection in motor circuits, lighting, and industrial equipment
The BUSSMANN GMC-4-R is a GMC Series time-delay cylindrical fuse rated 4 A at 125 V AC. It features a 5 mm x 20 mm package and is used for overcurrent protection in industrial equipment such as control panels, power supplies, and machinery
BUSSMANN
The BUSSMANN GMC-4-R is a GMC Series time-delay cylindrical fuse rated 4 A at 125 V AC. It features a 5 mm x 20 mm package and is used for overcurrent protection in industrial equipment such as control panels, power supplies, and machinery
Time-delay cylindrical fuse rated at 3.2 A and 250 V AC, with dimensions of 1/4 in x 1 1/4 in. Provides overcurrent protection in circuits where temporary inrush currents occur, such as motors and control circuits, preventing nuisance blowing while safeguarding against sustained faults
BUSSMANN
Time-delay cylindrical fuse rated at 3.2 A and 250 V AC, with dimensions of 1/4 in x 1 1/4 in. Provides overcurrent protection in circuits where temporary inrush currents occur, such as motors and control circuits, preventing nuisance blowing while safeguarding against sustained faults
Time-delay cylindrical fuse rated 800 mA, 250 V AC, with a 5 mm x 20 mm non-indicating body. Part of the S505 series, equivalent to 477 and GSF series. Used for overcurrent protection in circuits with temporary inrush currents, such as motor circuits, transformers, and control panels
BUSSMANN
Time-delay cylindrical fuse rated 800 mA, 250 V AC, with a 5 mm x 20 mm non-indicating body. Part of the S505 series, equivalent to 477 and GSF series. Used for overcurrent protection in circuits with temporary inrush currents, such as motor circuits, transformers, and control panels
Class RK5 time-delay cylindrical fuse rated 8 A, 600 V AC and 300 V DC. Non-indicating design from the FRS-R Series. Suitable for branch-circuit protection of motor circuits, transformers, and lighting panels, accommodating inrush currents without nuisance opening
BUSSMANN
Class RK5 time-delay cylindrical fuse rated 8 A, 600 V AC and 300 V DC. Non-indicating design from the FRS-R Series. Suitable for branch-circuit protection of motor circuits, transformers, and lighting panels, accommodating inrush currents without nuisance opening