We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

BUSSMANN Fuse: Class RK5, FRS-R Series, Time-Delay, 350 A, 600 V AC, 300 V DC - Time-Delay Blade Fuses
BUSSMANNTime-Delay Blade Fuses

BUSSMANN Fuse: Class RK5, FRS-R Series, Time-Delay, 350 A, 600 V AC, 300 V DC

The BUSSMANN FRS-R Series Fuse is a Class RK5, time-delay blade fuse rated at 350 A, 600 V AC and 300 V DC, non-indicating. This OEM-specified component delivers overcurrent protection with a time-delay…

SKU 3G-OTH-28463

Also listed as: FRSR350 · FRS R 350

Brand
BUSSMANN
Item
Fuse: Class RK5, FRS-R Series, Time-Delay, 350 A, 600 V AC, 300 V DC
Category
Time-Delay Blade Fuses
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

BUSSMANN
Manufacturer Part Number
FRS-R-350
Series
FRS-R
Type
FRS-R Series, Time-Delay, 350 A, Non-Indicating
AC
600 V
DC
300 V

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

BUSSMANN Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The BUSSMANN FRS-R Series Fuse is a Class RK5, time-delay blade fuse rated at 350 A, 600 V AC and 300 V DC, non-indicating. This OEM-specified component delivers overcurrent protection with a time-delay characteristic for industrial circuits. 3G Electric interprets your demand for this exact BUSSMANN part and sources it across our global supply network, backed by specialist expertise in electrical controls and power distribution.

Frequently Asked Questions

What is a BUSSMANN FRS-R-350 fuse used for?

The BUSSMANN FRS-R-350 is a Class RK5 time-delay fuse rated 350 A at 600 V AC or 300 V DC. It protects motors, transformers, and other inductive loads from short circuits and sustained overloads in industrial power distribution and control panels.

What are the specifications of the BUSSMANN FRS-R-350 fuse?

The BUSSMANN FRS-R-350 is a non-indicating, time-delay blade fuse from the FRS-R series. It is rated 350 A, 600 V AC, and 300 V DC. Its Class RK5 design provides high interrupting capacity for branch-circuit protection in industrial equipment.

Where to buy a BUSSMANN FRS-R-350 fuse worldwide?

3G Electric supplies the BUSSMANN FRS-R-350 fuse to customers worldwide. We handle full logistics, customs clearance, and delivery to your site. Contact us for a quote and lead time on this Class RK5 time-delay fuse.

How to select the right BUSSMANN FRS-R fuse for an application?

Select the BUSSMANN FRS-R fuse based on continuous load current (typically 125% of motor FLA), available fault current, and voltage rating. For 350 A circuits at 600 V AC or 300 V DC, the FRS-R-350 provides time-delay characteristics to handle inrush without nuisance opening.

Used in

Common applications for BUSSMANN
Industrial motor control centers — BUSSMANN LPT series Class T time-delay fuses for branch circuit protection
Semiconductor protection in variable frequency drives — BUSSMANN FWA series fast-acting bolt-on fuses rated 150 V AC/DC
Automotive auxiliary circuit protection — BUSSMANN CB222 series Type II circuit breakers in 12 V DC systems
Control panel overcurrent protection — BUSSMANN FNA series midget time-delay indicating fuses for instrumentation
Main feeder protection in power distribution — BUSSMANN KLU series Class L time-delay bolt-on fuses up to 650 A
Fuse replacement in existing panels — BUSSMANN S-8301-1-R fuse block accepting 3AG and other glass/ceramic fuses

BUSSMANN Products

3G Electric supplies BUSSMANN time-delay blade fuses. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
BUSSMANN Fuse: Class RK5, FRS-R Series, Time-Delay, 600 A, 600 V AC, 300 V DC, Non-Indicating (MPN FRS-R-600)
BUSSMANN
BUSSMANN Fuse: Class RK5, FRS-R Series, Time-Delay, 600 A, 600 V AC, 300 V DC, Non-Indicating (MPN FRS-R-600)
BUSSMANN Fuse: Class RK5, FRS-R Series, Time-Delay, 500 A, 600 V AC, 300 V DC, Non-Indicating (MPN FRS-R-500)
BUSSMANN
BUSSMANN Fuse: Class RK5, FRS-R Series, Time-Delay, 500 A, 600 V AC, 300 V DC, Non-Indicating (MPN FRS-R-500)
BUSSMANN Fuse: Class RK5, FRS-R Series, Time-Delay, 250 A, 600 V AC, 300 V DC, Non-Indicating (MPN FRS-R-250)
BUSSMANN
BUSSMANN Fuse: Class RK5, FRS-R Series, Time-Delay, 250 A, 600 V AC, 300 V DC, Non-Indicating (MPN FRS-R-250)
BUSSMANN Fuse: Class RK5, FRN-R Series, Time-Delay, 350 A, 250 V AC, 250 V DC, Non-Indicating (MPN FRN-R-350)
BUSSMANN
BUSSMANN Fuse: Class RK5, FRN-R Series, Time-Delay, 350 A, 250 V AC, 250 V DC, Non-Indicating (MPN FRN-R-350)
BUSSMANN Fuse: Class RK5, FRS-R Series, Time-Delay, 75 A, 600 V AC, 300 V DC, Non-Indicating (MPN FRS-R-75)
BUSSMANN
BUSSMANN Fuse: Class RK5, FRS-R Series, Time-Delay, 75 A, 600 V AC, 300 V DC, Non-Indicating (MPN FRS-R-75)
BUSSMANN Fuse: Class RK5, FRS-R Series, Time-Delay, 400 A, 600 V AC, 300 V DC, Non-Indicating (MPN FRS-R-400)
BUSSMANN
BUSSMANN Fuse: Class RK5, FRS-R Series, Time-Delay, 400 A, 600 V AC, 300 V DC, Non-Indicating (MPN FRS-R-400)

More from BUSSMANN

View all BUSSMANN parts
BUSSMANN Fuse: Class RK5, FRS-R Series, Time-Delay, 150 A, 600 V AC, 300 V DC, Non-Indicating (MPN FRS-R-150)
BUSSMANN
BUSSMANN Fuse: Class RK5, FRS-R Series, Time-Delay, 150 A, 600 V AC, 300 V DC, Non-Indicating (MPN FRS-R-150)
BUSSMANN Fuse: Class RK5, FRS-R Series, Time-Delay, 225 A, 600 V AC, 300 V DC, Non-Indicating (MPN FRS-R-225)
BUSSMANN
BUSSMANN Fuse: Class RK5, FRS-R Series, Time-Delay, 225 A, 600 V AC, 300 V DC, Non-Indicating (MPN FRS-R-225)
BUSSMANN Fuse: Class RK5, FRN-R Series, Time-Delay, 100 A, 250 V AC, 125 V DC, Non-Indicating (MPN FRN-R-100)
BUSSMANN
BUSSMANN Fuse: Class RK5, FRN-R Series, Time-Delay, 100 A, 250 V AC, 125 V DC, Non-Indicating (MPN FRN-R-100)
BUSSMANN Fuse: Class RK5, FRN-R Series, Time-Delay, 110 A, 250 V AC, 125 V DC, Non-Indicating (MPN FRN-R-110)
BUSSMANN
BUSSMANN Fuse: Class RK5, FRN-R Series, Time-Delay, 110 A, 250 V AC, 125 V DC, Non-Indicating (MPN FRN-R-110)
BUSSMANN Fuse: Class RK5, FRN-R Series, Time-Delay, 300 A, 250 V AC, 250 V DC, Non-Indicating (MPN FRN-R-300)
BUSSMANN
BUSSMANN Fuse: Class RK5, FRN-R Series, Time-Delay, 300 A, 250 V AC, 250 V DC, Non-Indicating (MPN FRN-R-300)
BUSSMANN Fuse: Class RK5, FRN-R Series, Time-Delay, 150 A, 250 V AC, 125 V DC, Non-Indicating (MPN FRN-R-150)
BUSSMANN
BUSSMANN Fuse: Class RK5, FRN-R Series, Time-Delay, 150 A, 250 V AC, 125 V DC, Non-Indicating (MPN FRN-R-150)
BUSSMANN Fuse: Class RK5, FRS-R Series, Time-Delay, 450 A, 600 V AC, 300 V DC, Non-Indicating (MPN FRS-R-450)
BUSSMANN
BUSSMANN Fuse: Class RK5, FRS-R Series, Time-Delay, 450 A, 600 V AC, 300 V DC, Non-Indicating (MPN FRS-R-450)
BUSSMANN Fuse: Class RK1, LPS-RK-SP Series, Time-Delay, 600 A, 600 V AC, 300 V DC, Non-Indicating (MPN LPS-RK-600SP)
BUSSMANN
BUSSMANN Fuse: Class RK1, LPS-RK-SP Series, Time-Delay, 600 A, 600 V AC, 300 V DC, Non-Indicating (MPN LPS-RK-600SP)