We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

3G Electric
BUSSMANN 15CLE-150E-D E-Rated Time-Delay Cylindrical Fuse - Time-Delay Cylindrical Fuses
BUSSMANNTime-Delay Cylindrical Fuses

BUSSMANN 15CLE-150E-D E-Rated Time-Delay Cylindrical Fuse

The BUSSMANN CLE Series is a time-delay cylindrical fuse, E-rated at 150 A and 14.4 kV AC, with an indicating feature (MPN 15CLE-150E-D). This medium-voltage fuse from BUSSMANN is designed for overcurrent protection…

SKU 3G-OTH-129880

Also listed as: 15CLE150ED · 15CLE 150E D

Brand
BUSSMANN
Item
15CLE-150E-D E-Rated Time-Delay Cylindrical Fuse
Part Number
15CLE-150E-D
Category
Time-Delay Cylindrical Fuses
Available to Order
Also known as:15CLE-150E-DBUSSMANN
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

BUSSMANN
Manufacturer Part Number
15CLE-150E-D
Type
E-Rated, Time-Delay, 150 A, 14.4 kV AC, Indicating

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

BUSSMANN Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The BUSSMANN CLE Series is a time-delay cylindrical fuse, E-rated at 150 A and 14.4 kV AC, with an indicating feature (MPN 15CLE-150E-D). This medium-voltage fuse from BUSSMANN is designed for overcurrent protection in industrial electrical systems.

Frequently Asked Questions

What is the BUSSMANN CLE Series medium voltage fuse used for?

The BUSSMANN CLE Series medium voltage fuse is used for overcurrent protection in industrial electrical systems. Its E-rated, time-delay design handles high inrush currents, making it suitable for motor circuits, transformers, and switchgear. The indicating feature allows quick visual identification of a blown fuse, reducing downtime.

What are the specifications of the BUSSMANN 15CLE-150E-D fuse?

The BUSSMANN 15CLE-150E-D is a CLE Series, E-rated, time-delay medium voltage fuse rated at 150 A and 14.4 kV AC. It features an indicating function for blown-fuse detection. The part number is 15CLE-150E-D, and it is a cylindrical fuse designed for industrial overcurrent protection.

Where to buy BUSSMANN medium voltage fuses worldwide?

You can source BUSSMANN medium voltage fuses, including the CLE Series, through 3G Electric. As a global industrial equipment distributor since 1990, 3G Electric handles full logistics, customs clearance, and delivery to worldwide destinations. Contact us for availability and lead time on the 15CLE-150E-D.

How to select the correct BUSSMANN CLE fuse for an application?

To select the correct BUSSMANN CLE fuse, match the voltage rating (14.4 kV AC) and current rating (150 A) to your system requirements. The E-rated, time-delay characteristic is ideal for circuits with high inrush currents, such as transformers. Always verify the interrupting rating and physical dimensions with your equipment specifications.

Used in

Common applications for BUSSMANN
Industrial drives — BUSSMANN FWC series fast-acting cylindrical fuses protect power semiconductors in AC/DC drive circuits.
Control transformers — BUSSMANN FNQ-R series time-delay fuses handle inrush currents in control power circuits.
Semiconductor protection — BUSSMANN KAC series bolt-on fuses safeguard diodes, thyristors, and IGBTs in AC-only applications.
Electrical panels — BUSSMANN FP-2, FP-3, FP-4, and FP-6 fuse pullers enable safe fuse replacement in distribution panels.
Automotive electrical systems — BUSSMANN FP-A3 fuse puller removes and installs 1/4 in and 1/2 in automotive fuses.
Power supplies — BUSSMANN FWC series fuses provide overcurrent protection in AC/DC power supply circuits.
Not sure this is the right part? Photo-identify it

BUSSMANN Products

3G Electric supplies BUSSMANN time-delay cylindrical fuses. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

More from BUSSMANN

View all BUSSMANN parts
Time-delay cylindrical fuse rated at 3.2 A and 250 V AC, with dimensions of 1/4 in x 1 1/4 in. Provides overcurrent protection in circuits where temporary inrush currents occur, such as motors and control circuits, preventing nuisance blowing while safeguarding against sustained faults
BUSSMANN
Time-delay cylindrical fuse rated at 3.2 A and 250 V AC, with dimensions of 1/4 in x 1 1/4 in. Provides overcurrent protection in circuits where temporary inrush currents occur, such as motors and control circuits, preventing nuisance blowing while safeguarding against sustained faults
BUSSMANN
BUSSMANN
R-rated, 2.4 kV AC, 100 A time-delay indicating fuse from the JCH Series. Provides overcurrent protection in medium-voltage industrial power distribution systems, such as motor circuits and switchgear
Time-delay cylindrical fuse rated 8 A, 250 V AC. Midget size, 13/32 x 1-1/2 in, non-indicating. Provides overcurrent protection with delayed response for inductive loads in control panels, motor circuits, and lighting systems
BUSSMANN
Time-delay cylindrical fuse rated 8 A, 250 V AC. Midget size, 13/32 x 1-1/2 in, non-indicating. Provides overcurrent protection with delayed response for inductive loads in control panels, motor circuits, and lighting systems
Time-delay cylindrical fuse rated 2.5 A at 250 V AC, 5 mm x 20 mm package. Designed for overcurrent protection in circuits with inductive loads such as motors and transformers, accommodating temporary inrush currents
BUSSMANN
Time-delay cylindrical fuse rated 2.5 A at 250 V AC, 5 mm x 20 mm package. Designed for overcurrent protection in circuits with inductive loads such as motors and transformers, accommodating temporary inrush currents
BUSSMANN
BUSSMANN
R-rated time-delay cylindrical fuse rated 4.8 kV AC and 450 A. Indicating feature provides visual blown-fuse indication. Used for overcurrent protection in medium voltage motor circuits, transformers, and switchgear where coordination with downstream devices and inrush current handling is required
Time-delay cylindrical fuse rated 1.5 A, 250 V AC, with 1/4 in x 1 1/4 in dimensions. Designed for overcurrent protection in circuits with moderate inrush currents, such as motors, transformers, and control panels
BUSSMANN
Time-delay cylindrical fuse rated 1.5 A, 250 V AC, with 1/4 in x 1 1/4 in dimensions. Designed for overcurrent protection in circuits with moderate inrush currents, such as motors, transformers, and control panels
BUSSMANN
BUSSMANN
R-Rated time-delay cylindrical fuse for medium-voltage overcurrent protection. Rated 4.8 kV AC and 700 A with indicating feature for visual blown-fuse indication. Suitable for motor circuits and transformer protection where inrush currents require time-delay characteristics
BUSSMANN
BUSSMANN
R-rated time-delay cylindrical fuse rated 4.8 kV AC and 650 A. Indicating feature provides visual blown-fuse indication. Used for overcurrent protection in medium-voltage circuits, coordinating with other protective devices and handling inrush currents from motors and transformers

Customer reviews

No reviews yet — be the first

Questions & answers