BURNDY KS203 Split-Bolt Connector, Copper, 4 AWG to 8 AWG - Split Bolts
BURNDYSplit Bolts

BURNDY KS203 Split-Bolt Connector, Copper, 4 AWG to 8 AWG

The BURNDY KS203 is a split-bolt connector designed for wire sizes 4 AWG to 8 AWG, featuring a copper body material. This split bolt from BURNDY is not rated for direct burial applications.

SKU 3G-OTH-16661

Also listed as: KS 203 · KS-203

Brand
BURNDY
Item
KS203 Split-Bolt Connector, Copper, 4 AWG to 8 AWG
Part Number
KS203
Category
Split Bolts
Available to Order
Also known as:KS203BURNDY
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
EXW Singapore
Collect or forward from our office
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Compliance & shipping

Hazardous material
Not classified as hazardous
California Prop 65 warning
No warning recorded
Licence required
No licence required
Safety Data Sheet
Not available
Special shipping
Ships under standard freight

Technical Specifications

BURNDY
Manufacturer Part Number
KS203
Torque
165 in-lb Torque This indicates the amount of torque required to terminate and shear off the fastening shear bolt lugs fully.
UNSPSC
39121409
Connects
Copper to Copper Wire
Standards
ARRA; EU RoHS
Head Style
Square Head
Body Finish
Unplated
Catalog Page
376
Hex Nut Size
0.68 in
Overall Length
1.2 in
Country of Origin
USA (subject to change)
Connector Material
Copper
Direct Burial Rated
No
Tap Wire Size Range
8 AWG – 4 AWG
Pressure Bar Material
Copper
Compatible with Series
Servit
For Maximum Run Wire Size
4 AWG For Maximum Run Wire Size This describes the maximum wire size that's compatible with the connector's run-side (incoming power) termination method.
For Maximum Tap Wire Size
4 AWG For Maximum Tap Wire Size This describes the maximum wire size that's compatible with the connector's tap-side (outgoing power) termination method.
For Minimum Run Wire Size
8 AWG For Minimum Run Wire Size This describes the minimum wire size that's compatible with the connector's run-side (incoming power) termination method.
For Minimum Tap Wire Size
8 AWG For Minimum Tap Wire Size This describes the minimum wire size that's compatible with the connector's tap-side (outgoing power) termination method.
Compatible with Product Type
Split Bolt Covers
Compatible Manufacturer Model Number
SC2
Minimum Tap Conductor w/1 Maximum Main (AWG)
14 AWG str

Technical Documents

No technical documents available for this product.
Request documentation →
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

BURNDY Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The BURNDY KS203 is a split-bolt connector designed for wire sizes 4 AWG to 8 AWG, featuring a copper body material. This split bolt from BURNDY is not rated for direct burial applications.

Frequently Asked Questions

What is the BURNDY KS203 split-bolt connector used for?

The BURNDY KS203 split-bolt connector is used for splicing or tapping copper wire in industrial electrical installations. It accommodates wire sizes 4 AWG to 8 AWG and is suitable for indoor or protected environments, as it is not rated for direct burial.

What are the specifications of the BURNDY KS203 split-bolt connector?

The BURNDY KS203 split-bolt connector has a copper body and accepts wire sizes 4 AWG to 8 AWG. It is not rated for direct burial. The manufacturer part number is KS203. This connector is designed for reliable splicing and tapping in electrical systems.

Where to buy the BURNDY KS203 split-bolt connector worldwide?

3G Electric supplies the BURNDY KS203 split-bolt connector to customers worldwide. We handle full logistics, customs clearance, and delivery to your location. Contact us for availability and lead time on this copper-body connector for wire sizes 4 AWG to 8 AWG.

How to install a BURNDY KS203 split-bolt connector?

To install the BURNDY KS203 split-bolt connector, strip the wire insulation to the recommended length, insert the conductors into the connector, and tighten the bolt to the manufacturer's torque specification. Ensure the connection is secure and insulated for the application environment.

Used in

Common applications for BURNDY
Industrial power distribution — BURNDY YA382NFXB two-hole compression lug for 500/550 kcmil stranded copper terminations
Grounding and bonding systems — BURNDY GRL5 copper ground rod clamp for direct-burial connections to 5/8 in rods
Switchgear and panel wiring — BURNDY YF25032UIL Type G barrel ferrule for 250 kcmil bare copper conductor ends
Overhead and service splices — BURNDY KS34 split-bolt connector for 500 kcmil to 2/0 AWG copper-to-copper taps
Field crimping and maintenance — BURNDY PATRIOT 600 cordless crimper with W, W-VT, and VT dies for up to 600 kcmil copper
Grounding electrode conductors — BURNDY KC28 copper-alloy grounding split bolt with 5/8"-11 stud for 1 to 4/0 AWG SOL
Not sure this is the right part? Photo-identify it→

BURNDY Products

3G Electric supplies BURNDY split bolts. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion →Pumps & Compressors →Spare Parts →All Products →

More from BURNDY

View all BURNDY parts →
Copper-body split-bolt connector for splicing or tapping copper wire. Accepts wire sizes 1 AWG to 6 AWG and 2 AWG to 6 AWG. Rated for direct burial, suitable for underground electrical connections in power distribution, grounding, and bonding applications
BURNDY
Copper-body split-bolt connector for splicing or tapping copper wire. Accepts wire sizes 1 AWG to 6 AWG and 2 AWG to 6 AWG. Rated for direct burial, suitable for underground electrical connections in power distribution, grounding, and bonding applications
The BURNDY KSA2/0 split-bolt connector features an aluminum body and is rated for direct burial. It accommodates wire sizes from 2/0 AWG to 2 AWG. This connector is used for splicing and tapping conductors in electrical systems, suitable for underground and outdoor applications where moisture resistance is required
BURNDY
The BURNDY KSA2/0 split-bolt connector features an aluminum body and is rated for direct burial. It accommodates wire sizes from 2/0 AWG to 2 AWG. This connector is used for splicing and tapping conductors in electrical systems, suitable for underground and outdoor applications where moisture resistance is required

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first