APPLETON ELECTRIC Hazardous Location Circuit Breaker: 2 Poles, 90 A Amps, 240V AC - Hazardous Location Enclosed Circuit Breakers
APPLETON ELECTRICHazardous Location Enclosed Circuit Breakers

APPLETON ELECTRIC Hazardous Location Circuit Breaker: 2 Poles, 90 A Amps, 240V AC

The APPLETON ELECTRIC Hazardous Location Enclosed Circuit Breaker (SKU 3G-OTH-21229) is a 2-pole, 90 A unit rated for 240V AC with a maximum AIR rating of 18kA at 240V AC. It features a 100/EHD frame size and…

SKU 3G-OTH-21229

Brand
APPLETON ELECTRIC
Item
Hazardous Location Circuit Breaker: 2 Poles, 90 A Amps, 240V AC
Category
Hazardous Location Enclosed Circuit Breakers
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

APPLETON ELECTRIC
Manufacturer Part Number
AEBB12290C
Type
18kA at 240V AC
AC
240V
Amps
90 A
Frame Size
100/EHD
Max. AIR Rating
18kA at 240V AC
AC Voltage Rating
240V AC
Circuit Breaker Included
Cutler-Hammer

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

APPLETON ELECTRIC Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The APPLETON ELECTRIC Hazardous Location Enclosed Circuit Breaker (SKU 3G-OTH-21229) is a 2-pole, 90 A unit rated for 240V AC with a maximum AIR rating of 18kA at 240V AC. It features a 100/EHD frame size and includes a Cutler-Hammer circuit breaker.

Frequently Asked Questions

What is the APPLETON ELECTRIC hazardous location circuit breaker used for?

This 2-pole, 90 A enclosed circuit breaker is designed for hazardous locations where flammable gases or dusts may be present. It provides overcurrent protection and disconnection for industrial electrical systems in environments requiring Class I, Division 2 ratings.

What are the specifications of the APPLETON ELECTRIC AEBB12290C?

The AEBB12290C is a 2-pole, 90 A circuit breaker rated for 240V AC with a maximum AIR rating of 18kA at 240V AC. It has a 100/EHD frame size and includes a Cutler-Hammer circuit breaker. The manufacturer part number is AEBB12290C.

Where to buy the APPLETON ELECTRIC AEBB12290C worldwide?

3G Electric supplies the APPLETON ELECTRIC AEBB12290C hazardous location circuit breaker to customers worldwide. We handle full logistics, customs clearance, and delivery to your site. Contact us for a quote and lead time on this Cutler-Hammer equipped unit.

How to select the right hazardous location circuit breaker?

Select a breaker based on voltage (240V AC), current rating (90 A), interrupting capacity (18kA), and environmental classification. The APPLETON ELECTRIC AEBB12290C with Cutler-Hammer breaker suits Class I, Division 2 areas. Always verify frame size (100/EHD) and local code requirements.

Used in

Common applications for APPLETON ELECTRIC
Oil and gas refineries — Appleton Electric EDSC21MC2 manual motor switch for controlling pumps in Class I, Division 1 areas
Chemical processing plants — Appleton Electric AEAB13420C hazardous location circuit breaker for motor protection in volatile environments
Pharmaceutical manufacturing — Appleton Electric FSK-1VDR weatherproof cover for duplex receptacles in washdown zones
Wastewater treatment facilities — Appleton Electric UNY250R-A aluminum conduit union for corrosion-resistant connections
Mining operations — Appleton Electric EDSC277-SA tandem 2-gang box for junction points in hazardous dust locations
Food and beverage processing — Appleton Electric JBK-75 iron cover for conduit access fittings in wet or dusty areas

APPLETON ELECTRIC Products

3G Electric supplies APPLETON ELECTRIC hazardous location enclosed circuit breakers. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
APPLETON ELECTRIC Hazardous Location Circuit Breaker: 2 Poles, 80 A Amps, 240V AC, 18kA at 240V AC (MPN AEBB12280C)
APPLETON ELECTRIC
APPLETON ELECTRIC Hazardous Location Circuit Breaker: 2 Poles, 80 A Amps, 240V AC, 18kA at 240V AC (MPN AEBB12280C)
APPLETON ELECTRIC Hazardous Location Circuit Breaker: 2 Poles, 70 A Amps, 240V AC, 18kA at 240V AC (MPN AEBB12270C)
APPLETON ELECTRIC
APPLETON ELECTRIC Hazardous Location Circuit Breaker: 2 Poles, 70 A Amps, 240V AC, 18kA at 240V AC (MPN AEBB12270C)
APPLETON ELECTRIC Hazardous Location Circuit Breaker: 3 Poles, 60 A Amps, 240V AC, 18kA at 240V AC (MPN AEBB13260C)
APPLETON ELECTRIC
APPLETON ELECTRIC Hazardous Location Circuit Breaker: 3 Poles, 60 A Amps, 240V AC, 18kA at 240V AC (MPN AEBB13260C)
APPLETON ELECTRIC Hazardous Location Circuit Breaker: 3 Poles, 90 A Amps, 240V AC, 18kA at 240V AC (MPN AEBB13290C)
APPLETON ELECTRIC
APPLETON ELECTRIC Hazardous Location Circuit Breaker: 3 Poles, 90 A Amps, 240V AC, 18kA at 240V AC (MPN AEBB13290C)
APPLETON ELECTRIC Hazardous Location Circuit Breaker: 3 Poles, 100 A Amps, 240V AC, 18kA at 240V AC (MPN AEBB13210C)
APPLETON ELECTRIC
APPLETON ELECTRIC Hazardous Location Circuit Breaker: 3 Poles, 100 A Amps, 240V AC, 18kA at 240V AC (MPN AEBB13210C)
APPLETON ELECTRIC Hazardous Location Circuit Breaker: 3 Poles, 70 A Amps, 240V AC, 18kA at 240V AC (MPN AEBB13270C)
APPLETON ELECTRIC
APPLETON ELECTRIC Hazardous Location Circuit Breaker: 3 Poles, 70 A Amps, 240V AC, 18kA at 240V AC (MPN AEBB13270C)

More from APPLETON ELECTRIC

View all APPLETON ELECTRIC parts
APPLETON ELECTRIC Hazardous Location Circuit Breaker: 3 Poles, 30 A Amps, 240V AC, 18kA at 240V AC (MPN AEAB13230C)
APPLETON ELECTRIC
APPLETON ELECTRIC Hazardous Location Circuit Breaker: 3 Poles, 30 A Amps, 240V AC, 18kA at 240V AC (MPN AEAB13230C)
APPLETON ELECTRIC Hazardous Location Circuit Breaker: 2 Poles, 225 A Amps, 600V AC, 65kA at 240V AC (MPN AEEB22622C)
APPLETON ELECTRIC
APPLETON ELECTRIC Hazardous Location Circuit Breaker: 2 Poles, 225 A Amps, 600V AC, 65kA at 240V AC (MPN AEEB22622C)
APPLETON ELECTRIC Hazardous Location Circuit Breaker: 3 Poles, 400 A Amps, 600V AC, 65kA at 240V AC (MPN AELB83640C)
APPLETON ELECTRIC
APPLETON ELECTRIC Hazardous Location Circuit Breaker: 3 Poles, 400 A Amps, 600V AC, 65kA at 240V AC (MPN AELB83640C)
APPLETON ELECTRIC Hazardous Location Circuit Breaker: 2 Poles, 700 A Amps, 600V AC, 65kA at 240V AC (MPN AELB82670C)
APPLETON ELECTRIC
APPLETON ELECTRIC Hazardous Location Circuit Breaker: 2 Poles, 700 A Amps, 600V AC, 65kA at 240V AC (MPN AELB82670C)
APPLETON ELECTRIC Hazardous Location Circuit Breaker: 2 Poles, 200 A Amps, 600V AC, 65kA at 240V AC (MPN AEEB22620C)
APPLETON ELECTRIC
APPLETON ELECTRIC Hazardous Location Circuit Breaker: 2 Poles, 200 A Amps, 600V AC, 65kA at 240V AC (MPN AEEB22620C)
APPLETON ELECTRIC Hazardous Location Circuit Breaker: 2 Poles, 60 A Amps, 240V AC, 18kA at 240V AC (MPN AEBB12260C)
APPLETON ELECTRIC
APPLETON ELECTRIC Hazardous Location Circuit Breaker: 2 Poles, 60 A Amps, 240V AC, 18kA at 240V AC (MPN AEBB12260C)
APPLETON ELECTRIC Hazardous Location Circuit Breaker: 2 Poles, 300 A Amps, 600V AC, 65kA at 240V AC (MPN AEFB42630C)
APPLETON ELECTRIC
APPLETON ELECTRIC Hazardous Location Circuit Breaker: 2 Poles, 300 A Amps, 600V AC, 65kA at 240V AC (MPN AEFB42630C)
APPLETON ELECTRIC Hazardous Location Circuit Breaker: 3 Poles, 125 A Amps, 480V AC, 65kA at 240V AC (MPN AECB13412C)
APPLETON ELECTRIC
APPLETON ELECTRIC Hazardous Location Circuit Breaker: 3 Poles, 125 A Amps, 480V AC, 65kA at 240V AC (MPN AECB13412C)