The APPLETON ELECTRIC Hazardous Location Lighting Fixtures: T3C Temp Code are bulb-dependent jelly jar hazardous location lights. They operate at 120V AC with a T3C temperature code and are rated for Class I, Div 1…

SKU 3G-OTH-390955

Also listed as: AC 1575 · AC-1575

Brand
APPLETON ELECTRIC
Item
AC1575 Bulb-Dependent Jelly Jar Hazardous Location Light
Part Number
AC1575
Category
Bulb-Dependent Jelly Jar Hazardous Location Lights
Available to Order
Also known as:AC1575APPLETON ELECTRIC
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

APPLETON ELECTRIC
Manufacturer Part Number
AC1575
Type
300 W, Ceiling Mount
AC
120V
Voltage
120V AC
Temperature Code
T3C
Emergency Battery Backup
No
Hazardous Location Rating
Class I, Div 1 and 2, Group C, D

Technical Documents

No technical documents available for this product.
Request documentation →
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

APPLETON ELECTRIC Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The APPLETON ELECTRIC Hazardous Location Lighting Fixtures: T3C Temp Code are bulb-dependent jelly jar hazardous location lights. They operate at 120V AC with a T3C temperature code and are rated for Class I, Div 1 and 2, Group C, D hazardous locations. This ceiling-mount fixture (MPN AC1575) does not include an emergency battery backup.

Frequently Asked Questions

What is the APPLETON ELECTRIC AC1575 hazardous location light used for?

The APPLETON ELECTRIC AC1575 is a bulb-dependent jelly jar fixture for Class I, Div 1 and 2, Group C, D hazardous locations. It provides 300 W, 120V AC ceiling-mount lighting in environments with flammable gases or vapors, such as oil refineries, chemical plants, and industrial processing facilities.

What are the specifications of the APPLETON ELECTRIC AC1575?

The APPLETON ELECTRIC AC1575 operates at 120V AC with a T3C temperature code. It is rated for Class I, Div 1 and 2, Group C, D hazardous locations. This ceiling-mount fixture supports 300 W and does not include an emergency battery backup. The manufacturer part number is AC1575.

Where to buy the APPLETON ELECTRIC AC1575 worldwide?

3G Electric supplies the APPLETON ELECTRIC AC1575 hazardous location light worldwide. As a global industrial distributor, we handle full logistics, customs clearance, and delivery to your site. Contact us for availability and lead time; we source and deliver this fixture to any international destination.

How to install the APPLETON ELECTRIC AC1575 ceiling-mount fixture?

Install the APPLETON ELECTRIC AC1575 by mounting it securely to a ceiling junction box rated for the hazardous location. Ensure power is off, connect 120V AC supply wires per local codes, and use a compatible bulb rated for the T3C temperature code. Always follow the manufacturer's installation manual and NEC/CEC requirements.

Used in

Common applications for APPLETON ELECTRIC
Oil and gas processing — Appleton Electric straight hazardous location metallic cable grips for securing power cords to equipment in Class I, Division 2 areas.
Chemical manufacturing — Appleton Electric UNY250R-A straight union for connecting rigid conduit to control enclosures in corrosive environments.
Petrochemical plants — Appleton Electric enhanced rating cord connectors with IP66 rating for washdown and dust-laden areas.
Pharmaceutical production — Appleton Electric brass cable grips with silver finish for sealing cords in Class II, Division 2 locations.
Wastewater treatment — Appleton Electric aluminum cable grips with 1-1/4 in MNPT for reliable cord termination in humid, outdoor installations.
Grain handling facilities — Appleton Electric cable grips rated for Class III, Division 2 to secure cords in dust-hazard zones.
Not sure this is the right part? Photo-identify it→

APPLETON ELECTRIC Products

3G Electric supplies APPLETON ELECTRIC bulb-dependent jelly jar hazardous location lights. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion →Pumps & Compressors →Spare Parts →All Products →

Compatible alternatives & equivalents

More from APPLETON ELECTRIC

View all APPLETON ELECTRIC parts →

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first