AMTROL WX-407C ASME Certified Commercial Steel Well Water Tank - ASME Certified Commercial Steel Well Water Tanks
AMTROLASME Certified Commercial Steel Well Water Tanks

AMTROL WX-407C ASME Certified Commercial Steel Well Water Tank

The AMTROL Well Tank: Well-X-Trol (MPN WX-407C) is an ASME Certified Commercial Steel Well Water Tank with a vertical installation type and a 132-gallon tank capacity. It is rated ASME Section VIII Division 1 and…

SKU 3G-OTH-100314

Also listed as: WX407C · WX 407C

Brand
AMTROL
Item
WX-407C ASME Certified Commercial Steel Well Water Tank
Part Number
WX-407C
Category
ASME Certified Commercial Steel Well Water Tanks
Available to Order
Also known as:WX-407CAMTROL
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

AMTROL
Manufacturer Part Number
WX-407C
Type
Vertical, Steel
Product Type
Water Tank
Tank Capacity
132 gal
ASME Compliance
Boiler and Pressure Vessel Code Section VII Division 1
Tank Install Type
Vertical
Precharge Pressure
25 psi
Includes Pump Stand
No Pump Stand Included
ASME Boiler and Pressure Rated
Rated ASME Section VIII Division 1

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

AMTROL Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The AMTROL Well Tank: Well-X-Trol (MPN WX-407C) is an ASME Certified Commercial Steel Well Water Tank with a vertical installation type and a 132-gallon tank capacity. It is rated ASME Section VIII Division 1 and complies with the Boiler and Pressure Vessel Code Section VII Division 1, with a 25 psi precharge pressure. No pump stand is included.

Frequently Asked Questions

What is the AMTROL Well-X-Trol WX-407C used for?

The AMTROL Well-X-Trol WX-407C is a commercial steel well water tank designed for vertical installation. It stores water under pressure using a 25 psi precharge, reducing pump cycling in municipal or well-water systems. Its ASME Section VIII Division 1 rating makes it suitable for commercial and industrial applications requiring code-compliant pressure vessels.

What are the specifications of the AMTROL Well-X-Trol WX-407C?

The AMTROL Well-X-Trol WX-407C is a vertical steel water tank with a 132-gallon capacity and 25 psi precharge pressure. It is ASME Section VIII Division 1 rated and complies with Boiler and Pressure Vessel Code Section VII Division 1. No pump stand is included. The manufacturer part number is WX-407C.

Where to buy the AMTROL Well-X-Trol WX-407C worldwide?

3G Electric supplies the AMTROL Well-X-Trol WX-407C to customers worldwide. As a global industrial equipment distributor since 1990, we handle full logistics, customs clearance, and delivery to your site. Contact us for availability and lead time; we source and deliver this ASME-rated commercial well tank to any international destination.

How to install the AMTROL Well-X-Trol WX-407C?

Install the AMTROL Well-X-Trol WX-407C vertically on a level, load-bearing surface. Connect the tank to the system piping using appropriate fittings, ensuring the precharge pressure of 25 psi is set before filling. Follow local plumbing codes and ASME guidelines for pressure vessel installation. Always depressurize the system before servicing.

Used in

Common applications for AMTROL
Residential well water systems — AMTROL Champion vertical tanks (e.g., CH-32, CH-44) for single-family homes
Commercial water pressure boosting — AMTROL Well-X-Trol ASME tanks (e.g., WX-403C) in multi-story buildings
Irrigation pressure control — AMTROL Champion tanks (e.g., CH-86) for agricultural water supply
Industrial process water storage — AMTROL Well-X-Trol tanks (e.g., WX-452C) in manufacturing facilities
Space-constrained installations — AMTROL Champion horizontal tank with pump stand (CH-14PS) for basements or utility rooms
Not sure this is the right part? Photo-identify it

AMTROL Products

3G Electric supplies AMTROL asme certified commercial steel well water tanks. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

More from AMTROL

View all AMTROL parts
Vertical steel well water tank with 264-gallon capacity and 25 psi precharge pressure. ASME certified under Boiler and Pressure Vessel Code Section VIII Division 1. Used in commercial water systems to maintain pressure and reduce pump cycling
AMTROL
Vertical steel well water tank with 264-gallon capacity and 25 psi precharge pressure. ASME certified under Boiler and Pressure Vessel Code Section VIII Division 1. Used in commercial water systems to maintain pressure and reduce pump cycling
Vertical steel well water tank with 90-gallon capacity and 25 psi precharge pressure. ASME Section VIII Division 1 rated and compliant with Boiler and Pressure Vessel Code Section VII Division 1. Used in commercial water systems to maintain consistent pressure and reduce pump cycling
AMTROL
Vertical steel well water tank with 90-gallon capacity and 25 psi precharge pressure. ASME Section VIII Division 1 rated and compliant with Boiler and Pressure Vessel Code Section VII Division 1. Used in commercial water systems to maintain consistent pressure and reduce pump cycling

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first