We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

3G Electric
AMERICRAFT FAN Clean Air Belt-Drive Fan with Drive - Clean Air Belt-Drive Fans with Drive
AMERICRAFT FANClean Air Belt-Drive Fans with Drive

AMERICRAFT FAN Clean Air Belt-Drive Fan with Drive

The AMERICRAFT FAN Axial Upblast Roof Exhaust Fan: Belt Drive is a Clean Air Belt-Drive Fan with Drive, model BRV-848-5-3-TEFC. It features a 48-inch blade, delivers 33,160 cfm, and is powered by a 5 hp TEFC motor…

SKU 3G-OTH-81211

Also listed as: BRV84853TEFC · BRV 848 5 3 TEFC

Brand
AMERICRAFT FAN
Item
Clean Air Belt-Drive Fan with Drive
Part Number
BRV-848-5-3-TEFC
Category
Clean Air Belt-Drive Fans with Drive
Available to Order
Also known as:BRV-848-5-3-TEFCAMERICRAFT FAN
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Compliance & shipping

Hazardous material
Not classified as hazardous
California Prop 65 warning
No warning recorded
Licence required
No licence required
Safety Data Sheet
Not available
Special shipping
Required — additional freight charges may applyThis item requires special shipping, additional charges may apply.

Technical Specifications

AMERICRAFT FAN
Manufacturer Part Number
BRV-848-5-3-TEFC
Type
33,160 cfm, TEFC, 5 hp, 3
AC
230/460V
Blade
48 in
Phase
3
UNSPSC
40101502
Current
6.7 A
Assembly
Assembled Assembly This indicates whether the fan ships fully assembled and ready to use, or must be assembled by the user before use.
Frequency
60 Hz
Base Shape
Square
Base Width
63 in
Drive Type
Belt Drive
Mount Type
Roof Curb
Application
Designed for General Ventilation in Production or Warehouse Areas Where Efficient Quiet Air Flow is Required
Base Height
2-1/2 in
Base Length
63 in
Damper Size
54 x 54 in
Motor Speed
800 RPM
Sound Level
45 sones @ 0.125 in SP and 5 ft; 45 sones @ 0.250 in SP and 5 ft
Bearing Type
Ball Bearing Pillow Block
Blade Finish
Galvanized
Catalog Page
2830
For Air Type
Clean Air
Housing Width
54 in
Overall Depth
63 in
Overall Width
63 in
Blade Diameter
48 in Blade Diameter
Blade Material
Steel
Housing Finish
Galvanized
Housing Length
54 in
Motor Location
Out of Airstream
Overall Height
57-1/4 in
Motor Enclosure
Totally Enclosed Fan Cooled
Brake Horsepower
4-1/2 hp
Housing Material
Steel
Motor Horsepower
5 hp Motor Horsepower Horsepower (HP) is the measurement of an HVAC motor’s output power. It expresses the rate at which the motor works to operate the fan.
Number of Blades
4
Number of Speeds
1
Overall Diameter
48 in
Country of Origin
USA (subject to change)
Maximum Fan Speed
800 RPM
Mounting Location
Roof
Nameplate Voltage
230/460V AC Nameplate Voltage This indicates the voltage rating inscribed on the nameplate. The voltage class (nominal voltage) required to operate the fan can vary slightly from this number.
Speed Controllable
No Speed Controllable This indicates whether an optional speed control can be used with the fan to adjust the fan's speed.
High-Efficiency Motor
No High-Efficiency Motor These fans include a high-efficiency, electronically commutated motor.
Maximum Static Pressure
1/2 in wc Maximum Static Pressure This is the maximum static pressure in inches of water column that these fans can overcome.
Maximum Ambient Temperature
104 °F
Maximum Inlet Air Temperature
104 °F Maximum Inlet Air Temperature This is the maximum temperature of air that can be moved through these fans safely. Exceeding this temperature may cause damage to the fan.
For High-Static Pressure Applications
No For High-Static Pressure Applications This indicates that a fan is built using a fan or blower wheel designed to move air through longer or more restrictive airways than regular designs.
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

AMERICRAFT FAN Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The AMERICRAFT FAN Axial Upblast Roof Exhaust Fan: Belt Drive is a Clean Air Belt-Drive Fan with Drive, model BRV-848-5-3-TEFC. It features a 48-inch blade, delivers 33,160 cfm, and is powered by a 5 hp TEFC motor with a single speed and a nameplate voltage of 230/460V AC.

Frequently Asked Questions

What is the AMERICRAFT FAN Axial Upblast Roof Exhaust Fan used for?

This belt-drive upblast fan is designed for industrial roof exhaust applications, removing hot air, fumes, or dust from manufacturing plants, warehouses, and commercial facilities. Its 48-inch blade delivers 33,160 cfm at 5 hp, making it suitable for high-volume ventilation where clean air is required.

What are the specifications of the AMERICRAFT FAN BRV-848-5-3-TEFC?

The AMERICRAFT FAN BRV-848-5-3-TEFC is a belt-drive axial upblast roof exhaust fan with a 48-inch blade, 33,160 cfm airflow, and a 5 hp TEFC motor. It operates at a single speed with a nameplate voltage of 230/460V AC, three-phase. The motor is totally enclosed fan-cooled for durability.

Where to buy the AMERICRAFT FAN BRV-848-5-3-TEFC worldwide?

3G Electric supplies the AMERICRAFT FAN BRV-848-5-3-TEFC to customers worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your site. Contact us for pricing and lead time on this belt-drive roof exhaust fan.

How to select the right belt-drive roof exhaust fan for my facility?

Select based on required cfm, static pressure, and motor voltage. The AMERICRAFT FAN BRV-848-5-3-TEFC delivers 33,160 cfm at 230/460V AC with a 5 hp TEFC motor. Ensure ductwork and roof curb match the 48-inch blade diameter. Consult a ventilation engineer for proper sizing and installation.

Used in

Common applications for AMERICRAFT FAN
Warehouse ventilation — AMERICRAFT FAN AML-30-3/4-3-TEFC direct-drive upblast exhaust fan for roof-mounted air removal
Commercial kitchen exhaust — AMERICRAFT FAN BRV-824-1/2-1-TEFC belt-drive fan for grease-laden air discharge
Chemical processing plant — AMERICRAFT FAN AML-48-10-3-EXP explosion-proof fan for flammable vapor exhaust
Manufacturing facility — AMERICRAFT FAN AM-24-1-3-TEFC direct-drive fan for general ventilation in high-ceiling areas
Parking garage — AMERICRAFT FAN AMLL-60-7 1/2-3-TEFC large-diameter fan for carbon monoxide exhaust
Food processing plant — AMERICRAFT FAN AML-42-5-3-TEFC clean air fan for humidity and odor control
Not sure this is the right part? Photo-identify it

AMERICRAFT FAN Products

3G Electric supplies AMERICRAFT FAN clean air belt-drive fans with drive. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

More from AMERICRAFT FAN

View all AMERICRAFT FAN parts
Belt-drive axial upblast roof exhaust fan with a 24-inch blade delivering 6,219 cfm. Single-speed TEFC 1/2 hp motor rated for 230/460V AC, 3-phase. Suitable for clean-air exhaust applications in industrial or commercial buildings, removing heat, fumes, and odors with upblast discharge directing exhaust away from the roof surface
AMERICRAFT FAN
Belt-drive axial upblast roof exhaust fan with a 24-inch blade delivering 6,219 cfm. Single-speed TEFC 1/2 hp motor rated for 230/460V AC, 3-phase. Suitable for clean-air exhaust applications in industrial or commercial buildings, removing heat, fumes, and odors with upblast discharge directing exhaust away from the roof surface
This belt-drive axial upblast roof exhaust fan is designed for clean-air applications, removing stale or hot air from industrial and commercial buildings. It features a 42-inch blade delivering 20,653 cfm, powered by a single-speed TEFC 2 hp motor rated at 115/230V AC. The upblast configuration directs exhaust upward, away from the roof surface
AMERICRAFT FAN
This belt-drive axial upblast roof exhaust fan is designed for clean-air applications, removing stale or hot air from industrial and commercial buildings. It features a 42-inch blade delivering 20,653 cfm, powered by a single-speed TEFC 2 hp motor rated at 115/230V AC. The upblast configuration directs exhaust upward, away from the roof surface
This belt-drive axial upblast roof exhaust fan is designed for clean-air applications, delivering 10,668 cfm with a 30-inch blade. It features a single-speed, TEFC 1 hp motor rated for 230/460V AC three-phase operation. Suitable for removing heat, smoke, or fumes from industrial and commercial buildings, its upblast discharge directs exhaust upward away from the roof surface
AMERICRAFT FAN
This belt-drive axial upblast roof exhaust fan is designed for clean-air applications, delivering 10,668 cfm with a 30-inch blade. It features a single-speed, TEFC 1 hp motor rated for 230/460V AC three-phase operation. Suitable for removing heat, smoke, or fumes from industrial and commercial buildings, its upblast discharge directs exhaust upward away from the roof surface

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first