AEROFLEX EPDM Straight Tube Insulation
AEROFLEX EPDM Straight Tube Insulation (SKU 300-AC3812, MPN 300-AC3812) is an unslit, 6 ft length with a 3/8 in ID and 1/2 in thickness, delivering an R-Value of 2.04. It is Plenum Rated, making it suitable for use…
SKU 3G-OTH-742266
Also listed as: 300AC3812 · 300 AC3812
Local availability & support
- Payment
- Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.
Compliance & shipping
- Hazardous material
- Not classified as hazardous
- California Prop 65 warning
- No warning recorded
- Licence required
- No licence required
- Safety Data Sheet
- Not available
- Special shipping
- Required — additional freight charges may applyThis item requires special shipping, additional charges may apply.
Ask a question
Request a QuoteAsk a question
Product Description
AEROFLEX EPDM Straight Tube Insulation (SKU 300-AC3812, MPN 300-AC3812) is an unslit, 6 ft length with a 3/8 in ID and 1/2 in thickness, delivering an R-Value of 2.04. It is Plenum Rated, making it suitable for use in air-handling spaces. 3G Electric sources this and thousands of other industrial products across 14 departments, with specialist expertise in combustion, pumps, and controls to ensure you get the right solution.
Frequently Asked Questions
What is AEROFLEX EPDM straight tube insulation used for?
AEROFLEX EPDM straight tube insulation is used to prevent condensation and reduce heat loss on small-diameter pipes in HVAC and refrigeration systems. Its plenum rating makes it suitable for installation in air-handling spaces such as ductwork plenums and above-ceiling return-air cavities.
What are the specifications of AEROFLEX 300-AC3812 pipe insulation?
The AEROFLEX 300-AC3812 is an unslit EPDM straight tube with a 3/8 in inside diameter, 1/2 in wall thickness, and 6 ft length. It provides an R-Value of 2.04 and is plenum rated. The manufacturer part number is 300-AC3812.
Where to buy AEROFLEX pipe insulation worldwide?
3G Electric supplies AEROFLEX pipe insulation worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your site. Contact us for a quote on the 300-AC3812 or any other AEROFLEX product you need.
How to install AEROFLEX EPDM unslit pipe insulation?
For unslit AEROFLEX EPDM insulation, slide the tube over the pipe before final connections are made. Ensure the pipe surface is clean and dry. Use manufacturer-recommended adhesive for butt joints and seal all seams to maintain the vapor barrier and achieve the rated R-Value.
AEROFLEX Products
3G Electric supplies AEROFLEX epdm straight tube insulation. We supply genuine products and their technical documentation.