We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

3G Electric

KILLARK LED

KILLARK, a brand under the Hubbell Industrial Lighting portfolio, manufactures LED lighting fixtures designed for hazardous locations. The product line focuses on luminaires that meet the requirements of Class III, Division 1 and 2 environments, as defined by the National Electrical Code (NEC). These fixtures are intended for use in areas where combustible fibers or flyings are present, such as textile mills, woodworking facilities, and grain handling operations. The KILLARK LED jelly jar series, represented by models like the EML4530A2G, EML4530X2G, and EML4530B2G, delivers 3,479 lumens at 45 watts with a color temperature of 5000K (cool white). They operate on 120/277V AC and carry a T6 temperature code, indicating a maximum surface temperature of 85°C, which is suitable for environments with specific ignition temperature limits. The fixtures are available in suspended, ceiling, and wall mount configurations, providing flexibility for installation in industrial settings. Construction typically features corrosion-resistant materials and sealed enclosures to prevent ingress of fibers and dust. While the brand is historically associated with explosion-proof enclosures and fittings, the LED line emphasizes energy efficiency and reduced maintenance compared to traditional incandescent or fluorescent hazardous location lighting. 3G Electric supplies these KILLARK LED fixtures to plant engineers, maintenance managers, and procurement specialists globally, supporting logistics for projects requiring certified hazardous location lighting. The fixtures are rated for Class III locations and comply with relevant UL standards for safety in combustible fiber environments. Buyers should verify specific installation requirements and local code compliance, as the fixtures are designed for fixed mounting and continuous operation in dry or damp locations. The 5000K color temperature provides high visibility for tasks in industrial areas, and the T6 rating ensures compatibility with processes that generate moderate heat. 3G Electric offers these units as part of a broader portfolio of industrial lighting solutions, with no minimum order quantities for standard configurations.

Genuine
OEM Parts
Expert
Tech Support
1 Day
Quote Response
Worldwide
Origin
Worldwide Shipping
Air & sea freight
Datasheets on Request
Technical specs & drawings
1-Day Quote Response
Singapore-based team
Show
Page 1 of 1

About KILLARK LED

KILLARK, a brand under the Hubbell Industrial Lighting portfolio, manufactures LED lighting fixtures designed for hazardous locations. The product line focuses on luminaires that meet the requirements of Class III, Division 1 and 2 environments, as defined by the National Electrical Code (NEC). These fixtures are intended for use in areas where combustible fibers or flyings are present, such as textile mills, woodworking facilities, and grain handling operations. The KILLARK LED jelly jar series, represented by models like the EML4530A2G, EML4530X2G, and EML4530B2G, delivers 3,479 lumens at 45 watts with a color temperature of 5000K (cool white). They operate on 120/277V AC and carry a T6 temperature code, indicating a maximum surface temperature of 85°C, which is suitable for environments with specific ignition temperature limits. The fixtures are available in suspended, ceiling, and wall mount configurations, providing flexibility for installation in industrial settings. Construction typically features corrosion-resistant materials and sealed enclosures to prevent ingress of fibers and dust. While the brand is historically associated with explosion-proof enclosures and fittings, the LED line emphasizes energy efficiency and reduced maintenance compared to traditional incandescent or fluorescent hazardous location lighting. 3G Electric supplies these KILLARK LED fixtures to plant engineers, maintenance managers, and procurement specialists globally, supporting logistics for projects requiring certified hazardous location lighting. The fixtures are rated for Class III locations and comply with relevant UL standards for safety in combustible fiber environments. Buyers should verify specific installation requirements and local code compliance, as the fixtures are designed for fixed mounting and continuous operation in dry or damp locations. The 5000K color temperature provides high visibility for tasks in industrial areas, and the T6 rating ensures compatibility with processes that generate moderate heat. 3G Electric offers these units as part of a broader portfolio of industrial lighting solutions, with no minimum order quantities for standard configurations.

Common Applications

  • Textile mills — KILLARK LED jelly jar lights (EML4530 series) for Class III fiber areas
  • Woodworking facilities — Suspended mount KILLARK LED fixtures over sawdust collection zones
  • Grain handling operations — Ceiling mount KILLARK LED lights in storage and processing areas
  • Paper recycling plants — Wall mount KILLARK LED fixtures near balers and conveyors
  • Cotton ginning facilities — KILLARK LED jelly jar lights for overhead illumination in ginning rooms
  • Fiberglass manufacturing — KILLARK LED fixtures in areas with combustible fiber byproducts

Frequently asked questions

Common questions about KILLARK LED from 3G Electric.

What hazardous location classifications do KILLARK LED jelly jar lights cover?

KILLARK LED jelly jar lights are rated for Class III, Division 1 and 2 locations as defined by the NEC. Class III environments involve combustible fibers or flyings, such as those found in textile mills, cotton gins, and woodworking plants. Division 1 applies where fibers are present under normal operating conditions, while Division 2 covers areas where fibers are only present during abnormal conditions. The fixtures are not rated for Class I (gas/vapor) or Class II (dust) locations unless explicitly marked.

What is the T6 temperature code on KILLARK LED fixtures and why does it matter?

The T6 temperature code indicates that the maximum surface temperature of the KILLARK LED fixture does not exceed 85°C under normal operating conditions. This is the lowest temperature code in the T-rating system, making the fixture suitable for environments where ignition-sensitive materials are present. For Class III locations, the T6 rating ensures the fixture will not ignite combustible fibers or flyings that may accumulate on the surface. Always verify that the T6 rating aligns with the autoignition temperature of the specific materials in your facility.

Can KILLARK LED jelly jar lights be used in wet or outdoor locations?

KILLARK LED jelly jar lights are designed for use in dry or damp locations, as indicated by their construction and typical UL listing. While the sealed enclosure provides protection against dust and fiber ingress, they are not explicitly rated for wet locations (e.g., direct rain or hose-down environments). For outdoor installations, ensure the fixture is mounted under an eave or canopy to avoid direct water exposure. Consult the product datasheet for specific IP ratings if required for your application.

What mounting options are available for KILLARK LED jelly jar fixtures?

KILLARK LED jelly jar fixtures are offered in three mounting configurations: suspended mount (model EML4530A2G), ceiling mount (EML4530X2G), and wall mount (EML4530B2G). The suspended mount uses a pendant or chain for overhead installation, the ceiling mount attaches directly to a junction box on a horizontal surface, and the wall mount secures to a vertical surface. All options use the same 45W LED module and provide 3,479 lumens at 5000K. Choose based on the structural layout and lighting distribution needs of your facility.

What voltage and wiring requirements do KILLARK LED jelly jar lights have?

KILLARK LED jelly jar lights operate on 120/277V AC, 50/60 Hz, making them compatible with standard North American industrial power systems. They are designed for direct connection to line voltage without the need for an external driver. The fixture includes a junction box for wiring, and installation should follow NEC guidelines for hazardous locations. Ensure the supply circuit is properly grounded and protected by a suitable overcurrent device. For international installations, verify voltage compatibility and local wiring codes.

Does 3G Electric supply KILLARK LED products?

Yes — 3G Electric (S) Pte. Ltd. supplies KILLARK LED products. We stock the KILLARK LED catalog and supply genuine factory-original products with full manufacturer warranty and technical support.