What is the difference between FLOODMASTER water detectors and FLOODMASTER shutoff systems?
FLOODMASTER water detectors are alarm-only devices that sense water and emit an audible alert. They do not control water flow. FLOODMASTER shutoff systems include a sensor, a control unit, and a valve actuator that automatically closes the water supply when a leak is detected. Shutoff systems are typically installed on water heater supply lines, appliance supply lines, or water mains. Detectors are used where automatic shutoff is not required or where a central shutoff valve is not present. Both product types are available in battery-powered and line-powered versions.
What voltage options are available for FLOODMASTER shutoff systems?
FLOODMASTER shutoff systems are available in 120V AC, 208V AC, and 240V AC configurations. The 120V AC models are common for water heater and water main applications. The 208V AC model is specified for hose-fed appliance leak detection. The 240V AC model is used for water heater supply lines with a 3/4 in NPT connection. Voltage selection must match the available power supply at the installation site. Some models include an actuator or receiver box as part of the assembly. Always verify the voltage and connection type against the specific SKU before ordering.
What sensor types does FLOODMASTER offer for leak detection?
FLOODMASTER leak detection systems use either rope sensors or magnetized water sensors. Rope sensors are available in lengths such as 10 ft with a 6 ft lead wire, and they are used in applications where leaks may occur along a path or in multiple locations. Magnetized water sensors have an 8 ft lead wire and are designed to be placed on a flat surface near the potential leak point. The sensor type affects the coverage area and installation method. Rope sensors are typically used for hose-fed appliances, while magnetized sensors are used for water heaters and water mains.
Are FLOODMASTER shutoff systems certified for potable water use?
Some FLOODMASTER shutoff systems are certified to NSF 372, which is the standard for lead-free plumbing products. This certification applies to specific models, such as the water main shutoff system and certain water heater shutoff systems. NSF 372 compliance indicates that the wetted materials meet the lead content requirements of the Safe Drinking Water Act. Not all FLOODMASTER products carry this certification. Check the individual product specifications for NSF 372 or other certifications before specifying for potable water lines.
What is the maximum operating temperature for FLOODMASTER water detectors?
The FLOODMASTER electric-corded water detector for condensate pan overflow detection has a maximum operating temperature of 100°F. This limit applies to the alarm unit and sensor. Battery-powered water detectors do not list a maximum operating temperature in the available specifications, but they are intended for indoor use in areas such as basements and utility rooms. Operating temperatures above the rated maximum may affect sensor accuracy or alarm function. Verify the temperature rating for the specific model before installation in high-temperature environments.
What connection sizes are available for FLOODMASTER shutoff valves?
FLOODMASTER shutoff valves are available with 1/2 in NPT and 3/4 in NPT connections. The 1/2 in NPT models are used for water heater supply lines and some appliance connections. The 3/4 in NPT models are used for water heater supply lines and water mains. Connection type is NPT (National Pipe Thread) for all listed shutoff systems. The valve body material is brass. When selecting a model, match the connection size to the existing piping. Adapters may be required for other thread standards. Always confirm the connection size and type from the product specifications.