We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

3G Electric

DAYTON GFCI

Dayton is a brand owned by OEM, a broad-line distributor of maintenance, repair, and operations (MRO) products. The Dayton name appears on a wide range of electrical and HVACR components, including the GFCI power cords supplied by 3G Electric. These cords are designed to provide ground-fault circuit-interrupter protection for equipment such as air conditioners, refrigeration units, and pumps. The GFCI mechanism continuously monitors the current balance between the hot and neutral conductors; if it detects a leakage current above a threshold (typically 4–6 mA), it disconnects power within milliseconds to reduce the risk of electric shock. This is particularly relevant in wet or damp environments where equipment may be exposed to moisture, or where operators work near grounded surfaces. The Dayton GFCI power cords are available in multiple configurations, with manufacturer part numbers VE2RDZ1GPCG, VE2RDZ2GPCG, VE2RDZ3GPCG, and VE2RDZ4GPCG. These part numbers correspond to different cord lengths, plug types, or amperage ratings, though specific electrical specifications should be confirmed with the manufacturer’s datasheet. The cords are intended for use with HVACR equipment, including air conditioners, refrigeration units, and pumps, in commercial and industrial settings. They are not general-purpose extension cords; they are specifically designed to integrate with the equipment’s power supply to provide personnel protection. 3G Electric supplies the Dayton GFCI line as part of its broader portfolio of industrial electrical and HVACR components. The company serves plant engineers, maintenance managers, and procurement specialists who require reliable, code-compliant components for facility operations. 3G Electric maintains inventory of multiple Dayton GFCI SKUs, including 23NY03, 23NY04, 23NY05, and 23NY06, and can provide quotations for specific part numbers. Because the Dayton GFCI cords are used in safety-critical applications, buyers should verify that the selected cord matches the equipment’s voltage, amperage, and plug/receptacle configuration. 3G Electric’s technical team can assist with cross-referencing part numbers and confirming availability. The product line is relevant to industries such as food and beverage processing, cold storage, water treatment, and manufacturing, where wet or humid conditions are common. In these environments, the use of GFCI protection is often mandated by electrical codes for personnel safety. The Dayton GFCI power cords offer a straightforward way to add or replace GFCI protection on existing equipment without rewiring the entire circuit. They are typically used as a replacement for damaged or missing cords, or as an upgrade to non-GFCI cords on equipment that operates in wet locations. 3G Electric ships globally, so customers outside the United States can also source these components. The company’s catalog includes the full range of Dayton GFCI part numbers currently available, and the team can provide lead times and shipping options upon request. For procurement specialists, 3G Electric offers a single point of contact for multiple MRO electrical items, reducing the need to manage numerous suppliers. The Dayton GFCI line is one example of the commodity electrical products that 3G Electric stocks to support maintenance and repair operations. All product details, including specifications and certifications, should be verified with the manufacturer’s documentation before purchase.

Genuine
OEM Parts
Expert
Tech Support
1 Day
Quote Response
Worldwide
Origin
Worldwide Shipping
Air & sea freight
Datasheets on Request
Technical specs & drawings
1-Day Quote Response
Singapore-based team
Show
Page 1 of 1

About DAYTON GFCI

Dayton is a brand owned by OEM, a broad-line distributor of maintenance, repair, and operations (MRO) products. The Dayton name appears on a wide range of electrical and HVACR components, including the GFCI power cords supplied by 3G Electric. These cords are designed to provide ground-fault circuit-interrupter protection for equipment such as air conditioners, refrigeration units, and pumps. The GFCI mechanism continuously monitors the current balance between the hot and neutral conductors; if it detects a leakage current above a threshold (typically 4–6 mA), it disconnects power within milliseconds to reduce the risk of electric shock. This is particularly relevant in wet or damp environments where equipment may be exposed to moisture, or where operators work near grounded surfaces. The Dayton GFCI power cords are available in multiple configurations, with manufacturer part numbers VE2RDZ1GPCG, VE2RDZ2GPCG, VE2RDZ3GPCG, and VE2RDZ4GPCG. These part numbers correspond to different cord lengths, plug types, or amperage ratings, though specific electrical specifications should be confirmed with the manufacturer’s datasheet. The cords are intended for use with HVACR equipment, including air conditioners, refrigeration units, and pumps, in commercial and industrial settings. They are not general-purpose extension cords; they are specifically designed to integrate with the equipment’s power supply to provide personnel protection. 3G Electric supplies the Dayton GFCI line as part of its broader portfolio of industrial electrical and HVACR components. The company serves plant engineers, maintenance managers, and procurement specialists who require reliable, code-compliant components for facility operations. 3G Electric maintains inventory of multiple Dayton GFCI SKUs, including 23NY03, 23NY04, 23NY05, and 23NY06, and can provide quotations for specific part numbers. Because the Dayton GFCI cords are used in safety-critical applications, buyers should verify that the selected cord matches the equipment’s voltage, amperage, and plug/receptacle configuration. 3G Electric’s technical team can assist with cross-referencing part numbers and confirming availability. The product line is relevant to industries such as food and beverage processing, cold storage, water treatment, and manufacturing, where wet or humid conditions are common. In these environments, the use of GFCI protection is often mandated by electrical codes for personnel safety. The Dayton GFCI power cords offer a straightforward way to add or replace GFCI protection on existing equipment without rewiring the entire circuit. They are typically used as a replacement for damaged or missing cords, or as an upgrade to non-GFCI cords on equipment that operates in wet locations. 3G Electric ships globally, so customers outside the United States can also source these components. The company’s catalog includes the full range of Dayton GFCI part numbers currently available, and the team can provide lead times and shipping options upon request. For procurement specialists, 3G Electric offers a single point of contact for multiple MRO electrical items, reducing the need to manage numerous suppliers. The Dayton GFCI line is one example of the commodity electrical products that 3G Electric stocks to support maintenance and repair operations. All product details, including specifications and certifications, should be verified with the manufacturer’s documentation before purchase.

Common Applications

  • Commercial refrigeration — Dayton GFCI power cord (e.g., VE2RDZ1GPCG) for walk-in coolers and freezers in wet environments.
  • Outdoor air conditioning — Dayton GFCI power cord (e.g., VE2RDZ2GPCG) for condenser units exposed to rain and humidity.
  • Food processing plants — Dayton GFCI power cord (e.g., VE2RDZ3GPCG) for pumps and washdown equipment requiring shock protection.
  • Water treatment facilities — Dayton GFCI power cord (e.g., VE2RDZ4GPCG) for sump pumps and mixers in damp locations.
  • Industrial maintenance — Dayton GFCI power cord (e.g., VE2RDZ1GPCG) as a replacement for damaged cords on portable HVACR equipment.
  • Cold storage warehouses — Dayton GFCI power cord (e.g., VE2RDZ2GPCG) for evaporator fan motors and defrost heaters.

Guides & Resources

Frequently asked questions

Common questions about DAYTON GFCI from 3G Electric.

What is the purpose of a Dayton GFCI power cord?

A Dayton GFCI power cord is designed to provide ground-fault circuit-interrupter protection for HVACR equipment. It continuously monitors the current flowing through the hot and neutral conductors. If the current difference exceeds a safe threshold (typically 4–6 milliamps), the GFCI trips and disconnects power within milliseconds. This reduces the risk of electric shock for personnel operating equipment in wet or damp locations. The cord is intended for use with air conditioners, refrigeration units, pumps, and similar equipment. It is not a substitute for proper grounding or overcurrent protection, but it adds a layer of personnel safety. Dayton GFCI cords are available in several part numbers, including VE2RDZ1GPCG, VE2RDZ2GPCG, VE2RDZ3GPCG, and VE2RDZ4GPCG.

What are the differences between Dayton GFCI part numbers VE2RDZ1GPCG, VE2RDZ2GPCG, VE2RDZ3GPCG, and VE2RDZ4GPCG?

The part numbers VE2RDZ1GPCG, VE2RDZ2GPCG, VE2RDZ3GPCG, and VE2RDZ4GPCG correspond to different configurations of Dayton GFCI power cords. These differences may include cord length, plug type (e.g., 5-15P, 5-20P), amperage rating (15A or 20A), voltage rating (120V or 240V), or the type of receptacle or connector on the equipment end. To select the correct part number, you must match the cord to your equipment’s electrical requirements and the available power source. The manufacturer’s datasheet for each part number provides the exact specifications. 3G Electric can assist with cross-referencing and confirming the correct part number for your application.

Can Dayton GFCI power cords be used outdoors or in wet locations?

Dayton GFCI power cords are intended for use with HVACR equipment in wet or damp environments, including outdoor installations. The GFCI mechanism provides protection against ground faults that can occur when moisture is present. However, the cord itself must be suitable for the environment. Some cords may have a jacket rating (e.g., SJTW, SOOW) that indicates resistance to water, sunlight, and abrasion. You should verify the cord’s environmental rating in the manufacturer’s specifications. Additionally, the GFCI plug end should be protected from direct immersion unless it is rated for such conditions. Always follow local electrical codes and the equipment manufacturer’s instructions regarding outdoor use.

How do I test a Dayton GFCI power cord?

Most Dayton GFCI power cords include test and reset buttons on the GFCI module. To test, plug the cord into a properly grounded receptacle and press the “TEST” button. The GFCI should trip, cutting power to the equipment. Press the “RESET” button to restore power. If the GFCI does not trip when tested, or if it trips repeatedly without a fault, the cord may be defective and should be replaced. You should test the GFCI before each use, especially in wet or damp locations. Refer to the manufacturer’s instructions for specific testing procedures and frequency. Do not use a GFCI cord that fails to test correctly.

What should I check before ordering a Dayton GFCI power cord from 3G Electric?

Before ordering, confirm the following: the equipment’s voltage and amperage requirements, the type of plug needed to connect to the power source, the type of connector needed for the equipment, and the required cord length. Also verify the environmental conditions (e.g., wet, outdoor, exposure to chemicals) to ensure the cord’s jacket rating is suitable. The Dayton part numbers VE2RDZ1GPCG, VE2RDZ2GPCG, VE2RDZ3GPCG, and VE2RDZ4GPCG have different specifications, so matching the part number to your application is critical. 3G Electric can provide quotations and lead times for these SKUs, and can help cross-reference if you have an existing part number.

Are Dayton GFCI power cords compatible with all HVACR equipment?

Dayton GFCI power cords are designed for HVACR equipment that operates on standard voltages and amperages, such as 120V or 240V, 15A or 20A. Compatibility depends on the equipment’s power requirements and the cord’s plug and connector types. Some equipment may require a specific plug configuration (e.g., NEMA 5-15P, 6-15P) or a special connector. You should always match the cord’s ratings to the equipment’s nameplate data. If the equipment has a high inrush current, the GFCI may nuisance trip; in such cases, a different type of protection may be needed. Consult the equipment manual and the cord’s specifications. 3G Electric can assist with selection.